Removing a management module
To remove a management module or filler, complete the following steps.
Notes:
1. These instructions assume that the BladeCenter unit is connected to power.
2. If you are replacing the only management module in the BladeCenter unit and
3. If you have just installed a second management module in the BladeCenter
1. Read the safety information that begins on page v and "Installation guidelines"
2. Disconnect all cables from the module.
3. Pull the release handle to the open position. The module moves out of the bay
4. Slide the module out of the bay. Within 1 minute, install either another
5. If you are instructed to return the management module, follow all packaging
46
BladeCenter H Type 8852, 7989, and 1886: Problem Determination and Service Guide
the management module is functioning, save the configuration file before you
proceed. See the BladeCenter Management Module User's Guide and the
BladeCenter Management Module Command-Line Interface Reference Guide for
instructions for saving and restoring a configuration file.
unit, do not remove the first (primary) management module for up to 45
minutes; the second (redundant) management module needs the time to receive
initial status information and firmware levels from the primary management
module.
Management
module
on page 29.
approximately 0.6 cm (0.25 inch).
management module or a filler into the bay.
instructions, and use any packaging materials for shipping that are supplied to
you.
Module
filler
Release handle