hit counter script

Re-Greasing - Siemens SIMOTICS DP 1PC1423 Operating Instructions Manual

Low-voltage motors, roller-table motors sh 112... 400
Table of Contents

Advertisement

Operating situations and characteristics can vary widely. For this reason, only general
maintenance intervals are specified here. Maintenance intervals should therefore be
scheduled to suit the local conditions (dirt, starting frequency, load, etc.).
Table 9-3
Measures
Initial inspection
Relubrication (optional)
Clean
Main inspection
Drain condensate
9.4.7

Re-greasing

For machines with regreasing system, relubrication intervals, grease quantity and grease grade
are provided on the lubricant plate. Additional data can be taken from the main machine rating
plate.
Grade of grease for standard motors (IP55) UNIREX N3 - ESSO.
Note
It is not permissible to mix different types of grease.
Prolonged storage periods reduce the useful lifetime of the bearing grease. Check the
condition of the grease if the equipment has been in storage for more than 12 months.
If the grease is found to have lost oil content or to be contaminated, the machine must
be immediately relubricated before commissioning. For information on permanently-greased
bearings, please refer to the section titled Rolling bearing (Page 96).
Procedure
To relubricate the rolling bearings, proceed as follows:
1. Clean the grease nipples at the drive end and non-drive end.
2. Press-in the specified grease and amount of grease according to the data stamped on the
lubrication plate.
– Please observe the information on the rating and lubricant plates.
– Regreasing should be carried out when the motor is running (max. 3600 rpm).
1PC1423 roller-table motors SH 112 ... 400
Operating Instructions
Operating period intervals
Operating period intervals
After 500 operating hours
Refer to the lubrication plate or the rating
plate
Depending on the degree of pollution
Approximately every 16000 operating
hours
Depending on the climatic conditions
Maintenance
9.4 Inspection and maintenance
Intervals
After 1/2 year at the latest
 
 
After two years at the latest
 
93