hit counter script

Upgrading Or Updating Cdf; When To Use Upgrade Or Update - IBM 3745 Connection And Integration Manual

Communication controller, nways multiprotocol controller
Table of Contents

Advertisement

Upgrading or Updating CDF

There are two related procedures that use the MOSS CDF function to change the
data in the configuration data file (CDF):

When to Use Upgrade or Update

At Initial Installation
First perform an Upgrade for the hardware changes, then, if you want to verify or
change the line parameters, perform an Update.
During a Later Modification
If you want to display or modify line parameters, perform an Update.
If you have made TRA cable change, perform an Upgrade.
If you have made other hardware changes, you can use either Upgrade or
Update depending on the changes you made. In general, use Update for a small
number of hardware changes; use Upgrade for many changes, but:
CDF Upgrade
This procedure causes the CDF to record all hardware changes that you are
making to the telecommunication lines connecting to the 3745. These include
LICs and cable changes for LICs, token-ring adapters (TRA), and high speed
scanners (HSS).
Note: The Upgrade function is disruptive. While using it, all lines attached
to the CCU that is being upgraded have to be taken out of operation for
15 minutes and the control program must be re-loaded.
CDF Update
This procedure causes the CDF to record certain hardware changes that you
are making to the telecommunication lines connecting to the 3745.
It also displays or modifies the telecommunication line parameters.
Not Always Necessary
It is not always necessary to change the CDF:
If you remove or install an Ethernet LAN AUI cable, no CDF change is
necessary.
Another example is if you replace a LIC by a spare LIC of the same type,
and do not change the line configuration. If you are unsure, use the
Display/Update CDF procedure, and verify the actual configuration.
If the MOSS is not alone, you can use Update to record hardware changes
without halting your system. You can at the same time make line parameter
changes.
The only disadvantage is the time it takes to enter each hardware change and
the possibility of errors during data entry.
If you can stop your system approximately 15 minutes, use Upgrade. The
hardware changes are put into the CDF automatically, quickly, and are less
error prone.
Chapter 5. Integration Procedures
5-7