hit counter script
Sony SNC-CH135 Release Notes
Hide thumbs Also See for SNC-CH135:

Advertisement

Quick Links

SNC-CH135/CH140/CH180/CH240/CH280
SNC-DH140/DH140T/DH180
SNC-DH240/DH240T/DH280
Release Note
Ver. 1.88
June 29, 2018
Sony Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Sony SNC-CH135

  • Page 1 SNC-CH135/CH140/CH180/CH240/CH280 SNC-DH140/DH140T/DH180 SNC-DH240/DH240T/DH280 Release Note Ver. 1.88 June 29, 2018 Sony Corporation...
  • Page 2 • Update: Major Improvements, Known Issues 2010/09/22 1.26 • First release for SNC-CH280/DH280 ・Add: New Function, Improved Function 2011/03/04 1.31 ・Update: Known Issues ・First release for SNC-CH135 2011/04/01 1.32.01 2011/04/28 1.34 Bug Fix • Add new Function, Improved Function 2011/08/22 1.50 •...
  • Page 3 2014/11/10 1.85 • Add Improved Function 2016/12/22 1.86 • Add New function for Ver. 1.86 • Add New function for Ver. 1.87 2017/04/25 1.87 • Add: New Function and Corrected Problem 2018/06/29 1.88 • Update: Known issues (37.12) Sony Corporation...
  • Page 4 17.2. Support ONVIF Profile which includes Audio only ........... 12 17.3. Several Time Zone settings will be available by using ONVIF command ..12 17.4. No update of Port number after changing HTTP’s port setting by using ONVIF Sony Corporation...
  • Page 5 20. Newly Added Functions in Ver. 1.75 ................14 20.1. Motion detection / Camera tampering detection / Audio detection support (SNC-CH135) ........................14 20.2. CGI command setting for WS-Discovery ............14 21. Function changed and Problems corrected in Ver. 1.75 ..........15 21.1.
  • Page 6: Table Of Contents

    32.1. Assigning the IP address to the camera by ARP commands ......20 33. Functional Restrictions ....................21 33.1. Audio Upload Tool ....................21 33.2. Camera tampering detection alarm (SNC-CH135 does not support) ....21 33.3. VMF function (SNC-CH135 does not support) ........... 21 33.4. SSL ........................21 33.5.
  • Page 7 37.9. Long-time Viewing with Smartphone Viewer ............ 26 37.10. Simultaneous pressing of multiple buttons with Smartphone Viewer .... 27 37.11. Camera tampering detection and Audio detection setting by SNC toolbox (SNC-CH135) ........................27 37.12. MPEG4 image may not be displayed in RTSP streaming ......... 27 Sony Corporation...
  • Page 8 Microsoft Internet Explorer Ver. 11.0 ( Windows 8.1 Desktop Mode only) Firefox Ver. 50.1 (Plug-in free viewer only) Google Chrome Ver. 55.0 (Plug-in free viewer only) • CPU Intel Core 2 Duo、2 GHz or higher (SNC-CH135/CH140/CH180/DH140/DH140T/ DH180) Intel Core 2 Duo、2.33 GHz or higher (SNC-CH240/CH280/DH240/DH240T/DH280) • Memory...
  • Page 9 This version supports Internet Explorer 11 (IE11) in Desktop User Interface Mode on Windows 8.1. But it does not support IE11 launching from Start Screen in Windows 8.1 and it has no evaluations of IE11 for Windows 7. Sony Corporation...
  • Page 10 (SNC-CH240/DH240/DH240T/CH280/DH280) Frame rate settings of Image size from ‘1280x720’ up to ‘1920x1080’ had been limited incorrect values in H.264 codec by using ONVIF command. (There has been no concern with CGI command.) This version improved this problem. Sony Corporation...
  • Page 11 17. Function changed and Problems corrected in Ver. 1.79 17.1. Erase unnecessary data in OSD with Focus indicator and so on Some parts of previous indications data had remained in OSD with Focus or Zoom indicator. This version improved this problem. (Problem from Ver. 1.77) Sony Corporation...
  • Page 12 (Problem from Ver. 1.31) Caution  The old data recorded in the media cannot be transformed into new format.  Depending on media, it has possibilities to produce a condition unrecordable for about 1 second infrequently under using this version. Sony Corporation...
  • Page 13 ONVIF Profile S is supported. Conformance to Profile S is validated with ONVIF Device Test Tool Version 12.06. 19. Function changed and Problems corrected in Ver. 1.77 19.1. Improvement of streaming video performance over SSL The frame rate of SSL streaming video is improved. Sony Corporation...
  • Page 14 20. Newly Added Functions in Ver. 1.75 20.1. Motion detection / Camera tampering detection / Audio detection support (SNC-CH135) SNC-CH135 has not ever supported Motion detection, Camera tampering detection, and audio detection. From this version these functions are available. 20.2. CGI command setting for WS-Discovery The following CGI command disables WS-Discovery protocol for ONVIF connection.
  • Page 15 Video capture used to always be done in 30fps. From this version it is possible to capture video in 25fps besides 30fps by setting menu and CGI command. For details on CGI command, refer to the CGI Command Manual. Sony Corporation...
  • Page 16 (Problem from Ver. 1.50) 24.4. Streaming problem in Smartphone viewer When HTTP port number is set to a number other than 80(default) in the Network menu, the streaming data could not be received in the Smartphone viewer. This problem has been Sony Corporation...
  • Page 17: Smartphone Viewer

    25.3. Smartphone viewer This is a viewer for smart phones to display an image or perform the PTZ operation by accessing from a smart phone. The user manual and support information for this function are at the following site. http://www.sony.net/ipela/snc Sony Corporation...
  • Page 18: Problems Corrected In Ver. 1.50

    “Auto”, there was a case where the infrared illuminator did not work in the Night mode. This problem has been fixed. (Problem since Ver. 1.31) 28. Newly Added Functions in Ver. 1.32.01 28.1. Supported models In this version, SNC-CH135 is supported. Sony Corporation...
  • Page 19: Newly Added Functions In Ver. 1.31

    Volume display of recording data (1 Stream) with Search cgi Size of the recording data is represented in kbyte unit.  On-Recording display of recording data with Search cgi Currently recording data and recorded data are distinguished as Recording and Recorded respectively. Sony Corporation...
  • Page 20: Changed Or Improved Functions In Ver. 1.31

    32. Changed or improved Functions in Ver. 1.26 32.1. Assigning the IP address to the camera by ARP commands The function that ARP commands assign an IP address to the camera is now selectable either ON or OFF. Please refer to CGI manual for details. Sony Corporation...
  • Page 21: Functional Restrictions

    When Proxy Server is set, Audio Upload Tool may be unable to connect to the target camera. Please disable the Proxy Server if this problem occurs. 33.2. Camera tampering detection alarm (SNC-CH135 does not support) When no motion detection setting is configured, please configure the motion detection area to the whole screen, or the performance of camera tampering detection will drop in some cases.
  • Page 22: Edge Storage

    Bandwidth control function for JPEG streaming is effective for TCP connection only. 33.9. Motion detection area setting When a detection area has 180 degrees or more interior angles by CGI command setting, motion detection function may not work correctly. Please set every interior angle under 180 Sony Corporation...
  • Page 23: Major Improvements At Ver. 1.32.01

    If pan/tilt operation was repeated during motion detection, there was a case where motion detection did not operate. This problem has been fixed. (Problem since Ver. 1.00) 35.5. Event file An abnormal frame existed in the event file. This problem has been fixed. (Problem since Ver. 1.22) Sony Corporation...
  • Page 24 (Problem from Ver. 1.10.01) 36.4. Bit-rate of MPEG-4 There was the problem that actual bit rate might become higher than selected bit-rate when the image codec was set to "MPEG-4". This problem has been corrected. (Problem from Ver. 1.10.01) Sony Corporation...
  • Page 25 36.7. Image size settings over limitation (SNC-CH240/DH240/DH240T) There was the problem that the video streaming might stop when irregular combination of resolutions on image 1 and image2 was selected. This problem has been corrected. (Problem from Ver. 1.10.01) Sony Corporation...
  • Page 26 At that time, please use the last character of folder name excluding number. 37.9. Long-time Viewing with Smartphone Viewer If a large image size is set for the video codec of the camera, the viewer may stop if the Sony Corporation...
  • Page 27 (SNC-CH135) SNC toolbox cannot set camera tampering detection and audio detection functions for SNC-CH135. Please set these functions by the setting menu. 37.12. MPEG4 image may not be displayed in RTSP streaming When viewing RTSP streaming with MPEG4 setting, image may not be displayed on some viewers.

Table of Contents