hit counter script
Raritan Crown Head Installation, Operation And Maintenance Instructions

Raritan Crown Head Installation, Operation And Maintenance Instructions

Centrifugal discharge automatic marine toilet

Advertisement

Quick Links

CENTRIFUGAL DISCHARGE SERIES AUTOMATIC MARINE TOILET
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING:
Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improperinstallation.
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
injury or death to personnel that may result from improper installation operation of this product.
WARNING:
HAZARD OF SHOCK OR FIRE
Always use recommended fuse, circuit breaker and wire size.
Motors and relays used with this product are "Ignition Protected". They are not however, ex-
plosion-proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
WARNING:
HAZARD OF FLOODING - Always shut off seacock(s) before leaving the boat unattended.
Whenever possible hose connections should be secured using two (2) all-stainless steel hose
clamps. Integrity of clamps, hoses and fittings should be checked periodically.
INTRODUCTION
The Crown Head is a powerful centrifugal
macerating toilet that thoroughly breaks down waste
in preparation for treatment or holding and requires
little maintenance. It can be ordered with a 90 degree
or straight discharge, a white marine-size bowl or
household-style bowl available in either white or
almond.
OPERATION
CAUTION: The Crown Head motor is designed
to be used as a toilet and is not rated for
continuous duty.
The Crown Head does not require special toilet
paper, however, hard objects or stringy substances
(paper towels, femine hygene products, filter
cigarettes, etc.) must not be thrown into the toilet as
they will cause damage.
A. Momentary Operation Using Push-button
Switch (#PBS) - not included: Depress button
and hold. Water should appear in the bowl within
one to four seconds. Flush as necessary.
B. Timer-Controlled Operation Using Raritime
Module (#RTC - See instructions supplied) -
not included: Depress button and release. Water
should appear in the bowl within one to four
seconds. Unit will run for a preset time (0 to 30)
seconds.
crown head
DO NOT run this system dry (without water).
DO NOT run continuously for more than 30 seconds.
MAINTENANCE
1. Refill the Concentrate reservoir when empty;
occasionally check that it has not run dry.
Concentrate helps minimize the need for
cleaning.
Use only Raritan Concentrate as an additive in
the Concentrate tank. Other products may cause
damage to the internal parts of the toilet.
2. Using C.P. a bio-enzymatic toilet bowl cleaner
(available from Raritan Engineering) will keep
the bowl clean and fresh smelling.
Do not use any chemical that contains ammonia,
ethyl acetate, phosphoric acid or concentrated
chlorine bleach as a cleaner. These may cause
damage to the toilet.
Fig. #1 CROWN HEAD - Overall Dimensions
14 3/8"(36.5)Household-style
13"(33cm)
Marine-size
17 3/8"
(44.1cm)
Household-style
17"
(43.2cm)
Marine-size
6 1/4"
(15.9cm)
10 7/8" (27.6cm)
11 7/8" (30.2cm)
1
20"(50.8cm) Household-style
17"(43.2cm) Marine-size
1/2" (1.3cm)
(approx.)
8 9/16"
(21.9cm)
13 7/8" (34.2cm)
2"
(5.1cm)

Advertisement

Table of Contents
loading

Summary of Contents for Raritan Crown Head

  • Page 1 FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product. Equipment damage, injury to personnel or death could result from improperinstallation. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment, injury or death to personnel that may result from improper installation operation of this product.
  • Page 2: System Components

    NOTE: Holding tanks, seacocks and treatment Place the supplied rubber mounting strips between systems need to be independently winterized, the base plate of the Crown Head and the deck, stored and recommissioned (see manufacturer’s allowing air to circulate under the motor to prevent instructions).
  • Page 3 Specification Table for (a longer hose [#CH42] is required, contact Raritan proper wire gauge and circuit breaker/fuse sizes. Technical Support). 12, 24 and 32 VDC Crown Head Units: Wire as per Fig. #4. (For momentary push button switch PLUMBING operation.)
  • Page 4: System Start-Up

    (Allowable Height of Toilet Above Waterline): 3 Ft. From Base of Toilet Duty Cycle: 30 Seconds On; 120 Seconds Off ONBOARD FRESHWATER USE: If you would like to retrofit your current Crown Head for use with pressurized freshwater please contact Raritan Technical Support.
  • Page 5: Troubleshooting

    TROUBLESHOOTING WARNING: HAZARD OF ELECTRIC SHOCK - Before beginning any work on the Crown Head, be sure that all power to the unit has been turned off and that the seacocks are in the CLOSED or OFF position. NOTE: The following information reflects the most probable causes and solutions to problems although not every possible cause and solution is provided.
  • Page 6 CROWN HEAD PARTS LIST (Quantities are one unless otherwise indicated) Before ordering, locate required part on exploded parts view to be sure you are ordering the correct part for your CROWN HEAD. Part No. Description Part No. Description 1118 Lockwasher (4)
  • Page 8: Limited Warranty

    1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW 2nd Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a sales slip or other document which establishes proof of purchase.

Table of Contents