hit counter script

Current Derating Depending On The Pulse Frequency - Siemens Sinamics PM250 Hardware Installation Manual

Table of Contents

Advertisement

Technical specifications
7.4 Power-dependent data
7.4.1

Current derating depending on the pulse frequency

Article number
6SL3225-...
-0BE25-5AA0
-0BE27-5AA0
-0BE31-1AA0
-0BE31-5AA0
-0BE31-8AA0
-0BE32-2AA0
-0BE33-0AA0
-0BE33-7AA0
-0BE34-5AA0
-0BE35-5AA0
-0BE37-5AA0
60
LO base
LO baseload output current [A] at a pulse frequency of...
load
4 kHz
6 kHz
power
7.5
18.0
12.5
11
25.0
18.1
15
32.0
24.7
18.5
38.0
32.3
22
45.0
38.3
30
60.0
51.0
37
75.0
63.8
45
90.0
76.5
55
110
93.5
75
145
123
90
178
151
8 kHz
10 kHz
12 kHz
11.9
10.6
9.20
17.1
15.2
13.3
23.4
20.8
18.2
26.6
22.8
19.0
31.5
27.0
22.5
42.0
36.0
30.0
52.5
45.0
37.5
63.0
54.0
45.0
77.0
--
102
--
125
--
Hardware Installation Manual, 01/2016, A5E36265179B-AA
14 kHz
16 kHz
7.90
6.60
11.4
9.50
15.6
12.8
17.1
15.2
20.3
18.0
27.0
24.0
33.8
30.0
40.5
36.0
--
--
--
--
--
--
--
--
--
PM250 Power Module