hit counter script

Rasmussen THR-2R Installation And Operating Instructions Manual

Multi-function wireless remote control system for operating a latching solenoid valve, manually or with a thermostat function

Advertisement

THR-2R INSTALLATION AND OPERATING INSTRUCTIONS
FOR OPERATING A LATCHING SOLENOID VALVE, MANUALLY OR WITH A THERMOSTAT FUNCTION
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT
INTRODUCTION
This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for gas heating
appliances. The system is operated manually from the transmitter. The system operates on radio frequencies (RF) within a 20' range
using non-directional signals. The system operates on one of 1,048,576 security codes that are programmed into the transmitter at the
factory; the remote receiver's code must be matched to that of the transmitter prior to initial use.
f i r e - p a r t s . c o m
Review COMMUNICATION SAFETY SECTION under TRANSMITTER section under REMOTE RECEIVER section. This signal safety
feature shuts down the fireplace system when a potentially unsafe condition exists.
TRANSMITTER
ON
BUTTON
ON
MODE
BUTTON
OFF
MODE
OFF
BUTTON
SET
SET
BUTTON
FRONT
ON
OFF
MODE
SET
MULIT-FUNCTION WIRELESS REMOTE CONTROL SYSTEM
ATTEMPT TO INSTALL OR OPERATE
This remote control SYSTEM offers the user a battery-operated remote control to
WALL CLIP
power a latching solenoid such as those used with gas valves used in some
SLOT
heater rated gas logs, gas fireplaces and other gas heating appliances.
The solenoid circuit uses the battery power from the receiver to operate a
solenoid. The circuit has reversing polarity software which reverses the positive
(+) and negative (-) output of the receiver's battery power to drive a latching
solenoid ON/OFF. The SYSTEM is controlled by the remote transmitter.
The transmitter operates on a (2) 1.5V AAA batteries.
It is recommended that ALKALINE batteries always be used for longer battery life
and maximum operational performance.
BATTERY
COMPARTMENT
Before using the transmitter, install the (2) AAA transmitter batteries into the
battery compartment. (Use caution that batteries are installed in the proper
direction)
BACK
1
2
ON
3
OFF
MODE - Changes unit from manual mode to thermostat mode.
SET
4
KEY SETINGS
- Operates unit to on position, Manually operated solenoid ON.
- Operates unit to off position, Manually operated solenoid OFF.
- Sets temperature in thermostat mode.
Page 1 of 7
REV. 1/25/08

Advertisement

Table of Contents
loading

Summary of Contents for Rasmussen THR-2R

  • Page 1 THR-2R INSTALLATION AND OPERATING INSTRUCTIONS MULIT-FUNCTION WIRELESS REMOTE CONTROL SYSTEM FOR OPERATING A LATCHING SOLENOID VALVE, MANUALLY OR WITH A THERMOSTAT FUNCTION IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for gas heating appliances.
  • Page 2: Manual Function

    LCD - Liquid Crystal Display DISPLAY Indicates CURRENT room temperature . F OR Indicates degrees Fahrenheit or Celsius. FLAME Indicates burner/valve in operation. ROOM Indicates remote is in THERMOSTAT operation. TEMP Appears during manual operation. ROOM TEMP Appears when setting the desired temperature for thermostat operation.
  • Page 3 for 3 seconds and the LCD screen will flash the set temperature for 3 seconds, then the LCD screen will default to display the room temperature. TO CHANGE THE SET TEMPERATURE Press and hold the SET key until the desired set temperature is reached.
  • Page 4: Installation Instructions

    20 ft. This THR-2R-1 remote receiver is to be connected to a manual valve with a latching ON/OFF solenoid. Connect two 18 gauge stranded or solid wires from the remote receiver terminals to the latching solenoid. (See figure to the right) IMPORTANT NOTE: Operation of this control is dependent on which wire is attached to which terminal.
  • Page 5: General Information

    GENERAL INFORMATION COMMUNICATION – SAFETY – TRANSMITTER This remote control has a COMMUNICATION – SAFETY function built into its software. It provides an extra margin of safety when the TRANSMITTER is out of the normal 20 foot operating range of the receiver. The COMMUNICATION –...
  • Page 6 BATTERY LIFE Life expectancy of the alkaline batteries in the THR-2R- can be up to 12 months depending on use of the solenoid function. Replace all batteries annually. When the transmitter no longer operates the remote receiver from a distance it did previously (i.e., the transmitter's range has decreased) or the remote receiver does not function at all, the batteries should be checked.
  • Page 7: Specifications

    SPECIFICATIONS BATTERIES: Transmitter (2) 1.5 volt AAA t bateries Remote Receiver 6V - 4 ea. AA 1.5 Alkaline FCC ID No.'s: transmitter - K9LSP1001TH; Operating Frequency: 303.8 MHZ Canadian IC ID No.'s: transmitter – 2439A-SP1001TH; FCC REQUIREMENTS NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.

Table of Contents