THR-2R INSTALLATION AND OPERATING INSTRUCTIONS
FOR OPERATING A LATCHING SOLENOID VALVE, MANUALLY OR WITH A THERMOSTAT FUNCTION
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT
INTRODUCTION
This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for gas heating
appliances. The system is operated manually from the transmitter. The system operates on radio frequencies (RF) within a 20' range
using non-directional signals. The system operates on one of 1,048,576 security codes that are programmed into the transmitter at the
factory; the remote receiver's code must be matched to that of the transmitter prior to initial use.
f i r e - p a r t s . c o m
Review COMMUNICATION SAFETY SECTION under TRANSMITTER section under REMOTE RECEIVER section. This signal safety
feature shuts down the fireplace system when a potentially unsafe condition exists.
TRANSMITTER
ON
BUTTON
ON
MODE
BUTTON
OFF
MODE
OFF
BUTTON
SET
SET
BUTTON
FRONT
ON
OFF
MODE
SET
MULIT-FUNCTION WIRELESS REMOTE CONTROL SYSTEM
ATTEMPT TO INSTALL OR OPERATE
This remote control SYSTEM offers the user a battery-operated remote control to
WALL CLIP
power a latching solenoid such as those used with gas valves used in some
SLOT
heater rated gas logs, gas fireplaces and other gas heating appliances.
The solenoid circuit uses the battery power from the receiver to operate a
solenoid. The circuit has reversing polarity software which reverses the positive
(+) and negative (-) output of the receiver's battery power to drive a latching
solenoid ON/OFF. The SYSTEM is controlled by the remote transmitter.
The transmitter operates on a (2) 1.5V AAA batteries.
It is recommended that ALKALINE batteries always be used for longer battery life
and maximum operational performance.
BATTERY
COMPARTMENT
Before using the transmitter, install the (2) AAA transmitter batteries into the
battery compartment. (Use caution that batteries are installed in the proper
direction)
BACK
1
2
ON
3
OFF
MODE - Changes unit from manual mode to thermostat mode.
SET
4
KEY SETINGS
- Operates unit to on position, Manually operated solenoid ON.
- Operates unit to off position, Manually operated solenoid OFF.
- Sets temperature in thermostat mode.
Page 1 of 7
REV. 1/25/08