Project planning information for indirect heating
7 .2 Radiant tubes
For ECOMAX . .C
Burners ECOMAX..C are intended for use with ceramic
radiant tubes SER-C.
See Technical Information SER-C.
Standard combinations:
Radiant tube
Burner
SER-C 100/088
ECOMAX 0C
SER-C 142/128
ECOMAX 1C
SER-C 162/148
ECOMAX 2C
SER-C 202/188
ECOMAX 3C
In special cases, a ceramic burner ECOMAX..C can be
installed in a metallic radiant tube. Here, external forces
on the ceramic burner due to the radiant tube being de-
formed must be excluded, however.
ECOMAX · Edition 10.17
Segmented flame tube
SICAFLEX 100/088/084
SICAFLEX 142/127/123
SICAFLEX 162/147/143
SICAFLEX 202/186/182
For ECOMAX . .M
Metallic radiant tubes are available in a variety of di-
mensions in either centrifugal casting or in welded
form. The efficiency of the burner ECOMAX..M is deter-
mined by the inside diameter d
the vicinity of the burner. The following dimensions are
recommended:
radiant tube inside
Burner
diameter d
ECOMAX 1M
ECOMAX 2M
ECOMAX 3M
ECOMAX 4M
ECOMAX 5M
If the inside diameter of the radiant tube is considerably
larger than that of the burner, a flue gas guide tube FGT
set should also be used.
Depending on the geometry, additional adapter flanges
may be required for radiant tubes.
of the radiant tubes in
i
Radiant tube inside
Min.
diameter d
as of which a
i
flue gas guide tube FGT
i
set is recommended
[mm]
[mm]
128
140
147
164
185
202
248
266
280
298
49