CM PtP communication module

(6ES7137-6AA00-
SIMATIC
ET 200SP
CM PtP communication module
(6ES7137-6AA00-0BA0)
Manual
01/2013
A5E03790792-01
0BA0)

___________________
Preface
___________________
Documentation guide
___________________
Product overview
___________________
Connecting
___________________
Parameters/address space
___________________
Programming
___________________
Error and system messages
___________________
Technical specifications
___________________
Dimensional drawing
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC ET 200SP

  • Page 1 ___________________ CM PtP communication module Preface (6ES7137-6AA00- 0BA0) ___________________ Documentation guide ___________________ Product overview SIMATIC ___________________ Connecting ET 200SP ___________________ CM PtP communication module Parameters/address space (6ES7137-6AA00-0BA0) ___________________ Programming Manual ___________________ Error and system messages ___________________ Technical specifications ___________________ Dimensional drawing 01/2013 A5E03790792-01...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Note on IT security Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. We recommend that you inform yourself regularly on the IT security developments regarding your products. You can find information on this on the Internet (http://support.automation.siemens.com).
  • Page 4 Siemens accepts no liability for the use of the open source software over and above the intended program sequence, or for any faults caused by modifications to the software.
  • Page 5: Table Of Contents

    Table of contents Preface ..............................3 Documentation guide..........................7 Product overview ............................9 Properties............................9 Accessories..........................10 Functions............................11 Properties of the interfaces ......................13 2.4.1 Properties of the RS232 interface....................13 2.4.2 Properties of the RS422/485 interface..................15 Connecting .............................. 17 RS232 and RS422/485 interface of the communication module..........17 Installation guidelines........................18 Parameters/address space ........................
  • Page 6 Table of contents CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 7: Documentation Guide

    Table 1- 1 Documentation for the CM PtP communication module Topic Documentation Key content System description System Manual S7 -1500 Automation System Application planning • (http://support.automation.siemens.com/WW/vi Installation • ew/en/59191792) Connecting • System Manual ET 200SP distributed I/O system Addressing •...
  • Page 8 Documentation guide SIMATIC Manuals All current manuals for the SIMATIC products are available for download free of charge on the Internet (http://www.siemens.com/automation/service&support). CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 9: Product Overview

    Product overview Properties Order number 6ES7137-6AA00-0BA0 View of the module Figure 2-1 View of CM PtP (without BaseUnit) CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 10: Accessories

    Accessories and spare parts for ET 200SP can be found in the System Manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). Online catalog Additional order numbers for ET 200SP can be found on the Internet (http://www.siemens.com/industrymall) in the online catalog and online ordering system. CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 11: Functions

    Product overview 2.3 Functions Functions Introduction The communication module allows you to exchange data between your own and other programmable controllers or computers by means of a point-to-point connection, and to connect various devices from a variety of manufacturers. Functionality of the CM PtP The CM PtP communication module offers the following functionality: ●...
  • Page 12 Additional information Information on configuration and programming of the CM PtP communications module is available in the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) and in the information system of the TIA Portal. CM PtP communication module (6ES7137-6AA00-0BA0)
  • Page 13: Properties Of The Interfaces

    Product overview 2.4 Properties of the interfaces Properties of the interfaces Interfaces of the CM PtP The CM PtP has the following interfaces, which are connected by means of the associated BaseUnit (see RS232 and RS422/485 interface of the communication module (Page 17) for assignment): ●...
  • Page 14 Product overview 2.4 Properties of the interfaces RS232 signals The table below shows the meaning of the individual RS232 accompanying signals. Table 2- 1 Signals of the RS232 interface Signal Designation Meaning Transmit Data Transmit data; transmit cable logically held to "1" by communication module in idle state.
  • Page 15: Properties Of The Rs422/485 Interface

    Product overview 2.4 Properties of the interfaces 2.4.2 Properties of the RS422/485 interface Definition - RS422/485 interface The RS422/485 (X27) interface is a differential voltage interface for serial data transmission. Properties - RS422/485 interface The RS422/485 (X27) interface has the following properties and meets the following requirements: Type Differential voltage interface...
  • Page 16 Product overview 2.4 Properties of the interfaces CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 17: Connecting

    Connecting RS232 and RS422/485 interface of the communication module Pin assignment Table 3- 1 RS232 connection Terminal assignment of the Designation Input/output Meaning communication module BaseUnit TXD Transmit Data Output Transmit data RXD Receive Data Input Receive data RTS Request To Send Output Request to send CTS Clear To Send...
  • Page 18: Installation Guidelines

    Ensure the power supply is disconnected before you wire the communication module. Additional information Information on connecting the modules can be found in the ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293) system manual. Installation guidelines To take into consideration The general installation guidelines must be taken into consideration (see function manual EMC/EMI compatible installation of control systems (http://support.automation.siemens.com/WW/view/en/59193566)).
  • Page 19: Parameters/Address Space

    Additional information The device manual of the communication module is supplemented by the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) and the TIA Portal information system. There you will find information on the following topics: ● Operating modes ●...
  • Page 20: Address Space

    Parameters/address space 4.3 Address space Address space Address space of the communication module The input addresses of the communications module total 8 bytes. The input addresses are automatically assigned for each communications module when you specify the device configuration in STEP 7 (TIA Portal). Output addresses are not required. Hardware identification (not freely configurable) The hardware identification (HW ID) is automatically assigned for each communications module when you specify the device configuration in STEP 7 (TIA Portal).
  • Page 21: Programming

    Programming Overview of the instructions Communication between the CPU, the communication module and a communication partner takes place by means of special instructions and protocols that support the corresponding communication modules. The instructions process the exchange of data between the CPU and the communication module.
  • Page 22 The instructions are part of STEP 7 (TIA Portal). The instructions are available in the "Instructions" task card under Communication > Communication processor. Additional information Additional information on programming the communication modules can be found in the function manual CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093). CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 23: Error And System Messages

    Error and system messages LED displays of the communication module The figure below shows the LED displays of the CM PtP communication module. ① LED display DIAG ② LED display TX ③ LED display RX ④ LED display PWR Figure 6-1 View of CM PtP (without BaseUnit) CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 24 Evaluate the diagnostics data and eliminate the error. Flashes 1) Information on communication module startup and diagnostics is available in the CM PtP - Configurations for point-to-point connections (http://support.automation.siemens.com/WW/view/en/59057093) function manual Meaning of the TXD/RXD LED displays Meaning Solution Interface is transmitting...
  • Page 25: Technical Specifications

    Technical specifications Technical specifications of the CM PtP communication module 6ES7137-6AA00-0BA0 Product type designation ET 200SP CM PtP General information Yes: I&M 0 I&M data • Engineering with STEP 7 TIA Portal can be configured/integrated V12.0 / V12.0 as of version STEP 7 can be configured/integrated as of V5.5 SP2 or higher with a GSD file version...
  • Page 26 Technical specifications 6ES7137-6AA00-0BA0 Interfaces 1. Interface Interface hardware RS 232 • RS 422 • RS 485 • Interface hardware RS 232 115.2 kbps Transmission rate, max. • 15 m Max. cable length • RS-232 accompanying signals RTS, CTS, DTR, DSR, RI, DCD RS 485 115.2 kbps Transmission rate, max.
  • Page 27 Technical specifications 6ES7137-6AA00-0BA0 Modbus RTU slave Address area 1 to 247, extended 1 to 65,535 Frame buffer 4 kbyte Buffer memory for frames • Number of frames which can be buffered • Interrupts/diagnostics/status information Interrupts Diagnostic interrupt • Hardware interrupt •...
  • Page 28 73 mm Height • 58 mm Depth • Weights 30 g Weight, approx. • Additional general technical specifications for SIMATIC ET 200SP can be found in the system manual S7-1500 Automation System (http://support.automation.siemens.com/WW/view/en/59191792). CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...
  • Page 29: Dimensional Drawing

    Dimensional drawing In this appendix, you will find the dimensional drawing of the communication module, inserted into a BaseUnit and mounted on a DIN rail. You have to consider the dimensions during installation in control cabinets, control rooms, etc (BaseUnit: 6ES7193-6BP00-0xA0). Figure A-1 Dimensional drawing of the CM PtP communication module CM PtP communication module (6ES7137-6AA00-0BA0)
  • Page 30 Dimensional drawing CM PtP communication module (6ES7137-6AA00-0BA0) Manual, 01/2013, A5E03790792-01...

Table of Contents