hit counter script
Siemens SIMATIC ET 200SP Manual
Hide thumbs Also See for SIMATIC ET 200SP:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC ET 200SP

  • Page 2 ___________________ CPU 1510SP F-1 PN Preface (6ES7510-1SJ00-0AB0) ___________________ Documentation guide ___________________ SIMATIC Product overview ___________________ Wiring ET 200SP CPU 1510SP F-1 PN Interrupts, error messages, ___________ diagnostics and system (6ES7510-1SJ00-0AB0) alarms ___________________ Manual Technical specifications ___________________ Dimension drawing 12/2014 A5E35264953-AA...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
  • Page 5: Table Of Contents

    Table of contents Preface ..............................4 Documentation guide ..........................6 Product overview ............................ 8 Operating principle ........................8 Properties ..........................9 Differences between F-CPU 1510SP F-1 PN and standard CPU 1510SP-1 PN ....12 Operating and display elements ..................... 14 2.4.1 Front view of the module with BusAdapter ................
  • Page 6: Documentation Guide

    Documentation guide The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require. Basic information The system manual describes in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200SP.
  • Page 7 Documentation guide Manual Collection ET 200SP The Manual Collection contains the complete documentation on the SIMATIC ET 200SP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet (http://support.automation.siemens.com/WW/view/en/84133942). My Documentation Manager The My Documentation Manager is used to combine entire manuals or only parts of these to your own manual.
  • Page 8: Product Overview

    Product overview Operating principle The CPU includes the operating system and executes the user program. The user program is located on the SIMATIC memory card and is processed in the CPU work memory. The PROFINET interfaces available on the CPU enable simultaneous communication with PROFINET devices, PROFINET controllers, HMI devices, programming devices, other controllers and additional systems.
  • Page 9: Properties

    Product overview 2.2 Properties Intelligent DP slave (I-slave) To use the ET 200SP as an intelligent DP slave (I-slave), you need the CPU and the optional communication module, CM DP. As an I-slave, ET 200SP is connected via PROFIBUS DP to the higher-level DP master and exchanges data with it.
  • Page 10 The CPU is delivered without a BusAdapter. You can find the article numbers of the supported BusAdapters in the "Accessories/spare parts" section of the ET 200SP Distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293) system manual. The PROFINET interface supports PROFINET IO RT (Realtime) and IRT (Isochronous Realtime) in addition to PROFINET basic functionality. PROFINET IO communication or real-time settings can be configured on the interface.
  • Page 11 You can find additional information on the topic of "Protection" in the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). ● The CPU 1510SP F-1 PN supports the following functions: – Safety mode – Firmware update –...
  • Page 12: Differences Between F-Cpu 1510Sp F-1 Pn And Standard Cpu 1510Sp-1 Pn

    Product overview 2.3 Differences between F-CPU 1510SP F-1 PN and standard CPU 1510SP-1 PN Differences between F-CPU 1510SP F-1 PN and standard CPU 1510SP-1 PN Areas of application CPU 1510SP F-1 PN is mainly used for the protection of personnel and machinery and burner controls.
  • Page 13 Product overview 2.3 Differences between F-CPU 1510SP F-1 PN and standard CPU 1510SP-1 PN Web server CPU 1510SP F-1 PN shows you the following on the start page of the web server: ● Safety mode activated/deactivated ● Collective signature ● Last fail-safe change ●...
  • Page 14: Operating And Display Elements

    Product overview 2.4 Operating and display elements Operating and display elements 2.4.1 Front view of the module with BusAdapter The figure on the left shows the CPU 1510SP-1 PN including a plugged BA 2xRJ45 BusAdapter. The figure on the right shows a separate view of the BA 2xRJ45 BusAdapter. ①...
  • Page 15: Mode Switch

    Product overview 2.5 Mode switch Mode switch Use the mode switch to set the CPU operating mode. The following table shows the position of the switch and the corresponding meaning. Table 2- 2 Mode switch settings Position Meaning Explanation RUN mode The CPU is executing the user program.
  • Page 16: Profienergy

    The majority of the energy is saved by the process; the PROFINET device itself only contributes a few watts of savings potential. Additional information ● See the PROFINET (http://support.automation.siemens.com/WW/view/en/68039307) function manual ● You will find more information on PROFIenergy in the PROFINET specification on the Internet (http://www.profibus.com).
  • Page 17: Profibus Dp

    Product overview 2.6 Functions 2.6.3 PROFIBUS DP With its optional PROFIBUS interface, CM DP, CPU 1510SP-1 PN supports the configuration of PROFIBUS networks in addition to PROFINET IO. PROFIBUS is the fieldbus network for the cell and field level. Physically, PROFIBUS is an electrical network based on a shielded two-wire cable or an optical network based on a fiber optic cable.
  • Page 18: Memory Reset

    Product overview 2.6 Functions Reference You will find additional information on "PROFIBUS DP" in the STEP 7 online help and in the PROFIBUS with STEP 7 (http://support.automation.siemens.com/WW/view/en/59193579) function manual. 2.6.4 Memory reset Apart from a few exceptions, a "memory reset" involves clearing all internal memories and then reading in the data on the SIMATIC memory card.
  • Page 19: Restoring The Factory Settings Of The Cpu

    Reference You can find additional information on the topic of "Memory reset" in the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). 2.6.5 Restoring the factory settings of the CPU The CPU can be reset to its factory state using "Reset to factory settings". The function deletes all information that was stored internally on the CPU.
  • Page 20 Product overview 2.6 Functions Procedure using the mode selector Make sure that there is no SIMATIC memory card in the CPU and that the CPU is in STOP mode (RUN/STOP LED lights up yellow). Reset to the factory settings as follows: 1.
  • Page 21 Reference You can find additional information on the topic of "Reset to factory settings" in the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293) and in the online help for STEP 7. CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0) Manual, 12/2014, A5E35264953-AA...
  • Page 22: Wiring

    Wiring This section provides information on the pin assignment of the individual interfaces and the block diagram of the CPU 1510SP-1 PN. 24 V DC supply voltage (X80) The connector for the supply voltage is plugged in when the CPU ships from the factory. The following figure shows the pin assignment for a 24 V DC supply voltage.
  • Page 23 Wiring PROFINET IO interface on the CPU (X1 P3) The table below shows the pin assignment of the PROFINET IO interface integrated in the CPU. The assignment corresponds to the Ethernet standard for an RJ45 plug. Table 3- 1 Pin assignment PROFINET IO interface on the CPU View Signal name Designation...
  • Page 24 Receive data + RD_N Receive data - Reference You can find additional information on the topics of "Connecting the CPU" and "Accessories/spare parts" in the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0) Manual, 12/2014, A5E35264953-AA...
  • Page 25 Wiring Assignment of the MAC addresses The MAC address is a globally unique device identifier that is assigned to each PROFINET device in the factory. Its 6 bytes are divided into 3 bytes for the manufacturer ID and 3 bytes for the device ID (serial number).
  • Page 26 Wiring Block diagram The following figure shows the block diagram of the CPU 1510SP-1 PN. ① Switch P1 R PROFINET interface X1 Port 1 ② Electronics P2 R PROFINET interface X1 Port 2 ③ Backplane bus interface PROFINET interface X1 Port 3 ④...
  • Page 27: Interrupts, Error Messages, Diagnostics And System Alarms

    The status and error displays of the CPU 1510SP-1 PN are described below. You will find additional information on "Interrupts" in the STEP 7 online help. You can find additional information on the topics of "Diagnostics" and "System alarms" in the Diagnostics (http://support.automation.siemens.com/WW/view/en/59192926) function manual. Status and error display of the CPU...
  • Page 28 Interrupts, error messages, diagnostics and system alarms 4.1 Status and error display of the CPU Meaning of the LED displays CPU 1510SP-1 PN features an LED for monitoring the supply voltage of the electronics (PWR) and three LEDs for displaying the current operating and diagnostics status. The following table shows the meaning of the various combinations of colors for the POWER, RUN/STOP, ERROR and MAINT LEDs.
  • Page 29 Interrupts, error messages, diagnostics and system alarms 4.1 Status and error display of the CPU Meaning of the LEDs of the interfaces: X1 P1 R, X1 P2 R and X1 P3 Each port has a LINK LED (LK1, LK2, LK3). The table below shows the various "LED scenarios"...
  • Page 30: Technical Specifications

    Technical specifications Technical specifications 6ES7510-1SJ00-0AB0 Product type designation CPU 1510SP F-1 PN General information Hardware version FS01 Firmware version V1.7 Engineering with STEP 7 TIA Portal can be configured/integrated V13 SP1 as of version Configuration control Via data record Operator controls Mode selector Supply voltage Type of supply voltage...
  • Page 31 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 Buffering Maintenance-free CPU processing time For bit operations, typ. 72 ns For word operations, typ. 86 ns For fixed-point arithmetic, typ. 115 ns For floating-point arithmetic, typ. 461 ns CPU blocks Number of elements (total) 2000;...
  • Page 32 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 IEC counters Number Unlimited (only limited by work memory) Retentivity Configurable • S7 timers Number 2048 Retentivity Configurable • IEC timers Number Unlimited (only limited by work memory) Retentivity Configurable • Data areas and their retentivity Total retentive data area (including timers, coun- 128 KB;...
  • Page 33 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 Number of IO controllers Integrated Via CM Rack Modules per rack, max. 64; CPU + 64 modules + server module (configu- ration width max. 1 m) Rack, number of rows, max. PtP CM Number of PtP CMs The number of PtP CMs that can be connected is only limited by number of the available slots.
  • Page 34 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 2. interface Interface hardware Number of ports • Yes; via CM DP module RS 485 • Protocols SIMATIC communication • PROFIBUS DP master • PROFIBUS DP slave • Interface hardware RJ45 (Ethernet) 100 Mbps Autonegotiation Autocrossing Industrial Ethernet status LED...
  • Page 35 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 Number of IO devices that can be activat- • ed/deactivated simultaneously, max. Number of IO devices per tool changer, max. • Minimum value of update time also depends on Update times • the configured communication share for PROFINET IO, on the number of IO devices and the amount of configured user data.
  • Page 36 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 Open IE communication TCP/IP 64 KB Data length, max. • Several passive connections per port, support- • ISO-on-TCP (RFC1006) 64 KB Data length, max. • 1472 bytes Data length, max. • DHCP SNMP LLDP Web server HTTP Yes;...
  • Page 37 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 S7 signaling functions Number of stations that can be registered for sig- naling functions, max. Block-related alarms Number of configurable interrupts, max. 5000 Number of simultaneously active interrupts in interrupt pool Number of reserved user interrupts •...
  • Page 38 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 Supported technology objects Motion Speed-controlled axis • 6; max. number of speed-controlled axes (re- – Number of speed-controlled axes, max. quirement: no other motion technology objects have been created) Positioning axis • 6; max. number of positioning axes (requirement: –...
  • Page 39 Technical specifications 5.1 Technical specifications 6ES7510-1SJ00-0AB0 Configuration Programming Programming language Yes; with fail-safe • Yes; with fail-safe • • • GRAPH • Know-how protection User program protection Copy protection Block protection Access protection Protection level: Write protection Yes; a specific write protection in each case for both standard and fail-safe Protection level: Read/write protection Protection level: Complete protection...
  • Page 40: Dimension Drawing

    Dimension drawing This section contains a dimension drawing of the module mounted on a mounting rail. Always observe the specified dimensions for installation in cabinets, control rooms, etc. Dimension drawing of the CPU 1510SP-1 PN Figure A-1 Dimension drawing 1510SP-1 PN CPU 1510SP F-1 PN (6ES7510-1SJ00-0AB0) Manual, 12/2014, A5E35264953-AA...

Table of Contents

Save PDF