hit counter script

Troubleshooting - Sealey BSCU170 Manual

Battery charger/power supply
Table of Contents

Advertisement

15. TROUBLESHOOTING

PROBLEM
NO DISPLAY AND THE LEDS ARE
NOT LIT.
DISPLAY READS 0.0 VOLTS.
AMPS READING ON DISPLAY READS
LESS THAN SELECTED CHARGE RATE
WHEN CHARGING A DISCHARGED
BATTERY.
THE BATTERY IS CONNECTED AND
THE CHARGER IS ON, BUT IS NOT
CHARGING.
CHARGER HAS SHUT DOWN OR WILL
NOT TURN ON WHEN PROPERLY
CONNECTED.
THE COOLING FAN IS MAKING A
RATTLING NOISE.
THE VOLTMETER READING IS LESS
THAN 10.5 VOLTS.
THE VOLTMETER READING IS
BETWEEN 10.5 AND 12.7V.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
POSSIBLE CAUSE
CHARGER IS NOT PLUGGED IN.
NO POWER AT THE RECEPTACLE.
CLAMPS ARE NOT MAKING A GOOD
CONNECTION TO THE BATTERY.
CONNECTIONS ARE REVERSED.
BATTERY IS DEFECTIVE (WILL NOT
ACCEPT A CHARGE).
EXTENSION CORD IS TOO LONG OR
WIRE GAUGE IS TOO SMALL.
WEAK CELL OR SULFATED PLATE IN
BATTERY.
THE CHARGER REACHED THE
MAXIMUM VOLTAGE AND IS
REDUCING THE CURRENT.
BATTERY IS SEVERELY DISCHARGED
(AUTOMATIC MODE ONLY).
THE CHARGER HAS BECOME TOO HOT
AND IT HAS SHUT DOWN.
THE FAN HAS A BUILD UP OF DIRT
AND GRIME, CAUSING IT TO BE
UNBALANCED.
THE BATTERY MAY BE BAD OR THE
CONNECTION AT THE CHARGER MAY
BE POOR.
THE BATTERY IS LOW.
01284 703534
sales@sealey.co.uk
Original Language Version
SOLUTION
PLUG THE CHARGER INTO AN AC
OUTLET.
CHECK FOR OPEN FUSE OR CIRCUIT
BREAKER SUPPLYING AC OUTLET.
CHECK FOR POOR CONNECTION TO
BATTERY AND FRAME. MAKE SURE
CONNECTION POINTS ARE CLEAN.
ROCK CLAMPS BACK AND FORTH FOR
A BETTER CONNECTION.
UNPLUG THE CHARGER AND
REVERSE THE CLIPS.
HAVE BATTERY CHECKED.
USE A SHORTER OR HEAVIER GAUGE
EXTENSION CORD.
A SULFATED BATTERY WILL
EVENTUALLY TAKE A NORMAL
CHARGE IF LEFT CONNECTED. IF THE
BATTERY WILL NOT TAKE A CHARGE,
HAVE IT CHECKED.
NO PROBLEM; THIS IS A NORMAL
CONDITION. CONTINUE TO CHARGE
THE BATTERY AND SEE BATTERY
PERCENT AND CHARGE TIME
SECTION, CHARGE RATE SUBSECTION
IF YOUR BATTERY DOES NOT HAVE 1
VOLT, YOU MUST PRESS AND HOLD
FOR FIVE SECONDS.
THE CHARGER HAS THERMAL
PROTECTION, AND IT WILL SHUT
DOWN IF IT GETS TOO HOT. UNPLUG
THE AC CORD AND LET THE CHARGER
COOL DOWN. MAKE SURE THERE IS
NOTHING OBSTRUCTING THE AIR
FLOW TO THE FANS, CLEAN THEM AS
SHOWN IN MAINTENANCE
INSTRUCTIONS
BLOW THE DIRT AND GRIME OFF THE
FAN BLADES USING COMPRESSED
AIR AS DESCRIBED IN
MAINTENANCE INSTRUCTIONS.
HAVE THE BATTERY CHECKED.
RECHARGE THE BATTERY.
www.sealey.co.uk
BSCU170 Issue:1 - 25/10/18

Advertisement

Table of Contents
loading