Bico Parameters (Connectors/Binectors) - Siemens SINAMICS G120 List Manual

Cu250s-2 control units
Hide thumbs Also See for SINAMICS G120:

Advertisement

p1230[0...n]
p1476[0...n]
p1477[0...n]
p1492[0...n]
p1501[0...n]
p1502[0...n]
p1545[0...n]
p2080[0...15]
p2081[0...15]
p2082[0...15]
p2083[0...15]
p2084[0...15]
p2103[0...n]
p2104[0...n]
p2105[0...n]
p2106[0...n]
p2107[0...n]
p2108[0...n]
p2112[0...n]
p2116[0...n]
p2117[0...n]
p2144[0...n]
p2148[0...n]
p2200[0...n]
p2220[0...n]
p2221[0...n]
p2222[0...n]
p2223[0...n]
p2235[0...n]
p2236[0...n]
p2286[0...n]
p2290[0...n]
p2508[0...3]
p2509[0...3]
p2510[0...3]
p2511[0...3]
p2512[0...3]
p2514[0...3]
p2549
p2550[0...n]
p2551
p2552
p2553
p2554
p2568
p2569
p2570
p2575
p2577
p2582
p2589
p2590
p2591
p2595
p2596
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
BI: DC braking activation / DC brake act
BI: Speed controller hold integrator / n_ctrl integ stop
BI: Speed controller set integrator value / n_ctrl integ set
BI: Droop feedback enable / Droop enable
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
BI: Freeze moment of inertia estimator / J_estim freeze
BI: Activates travel to a fixed stop / TfS activation
BI: Binector-connector converter status word 1 / Bin/con ZSW1
BI: Binector-connector converter status word 2 / Bin/con ZSW2
BI: Binector-connector converter status word 3 / Bin/con ZSW3
BI: Binector-connector converter status word 4 / Bin/con ZSW4
BI: Binector-connector converter status word 5 / Bin/con ZSW5
BI: 1st acknowledge faults / 1st acknowledge
BI: 2nd acknowledge faults / 2nd acknowledge
BI: 3rd acknowledge faults / 3rd acknowledge
BI: External fault 1 / External fault 1
BI: External fault 2 / External fault 2
BI: External fault 3 / External fault 3
BI: External alarm 1 / External alarm 1
BI: External alarm 2 / External alarm 2
BI: External alarm 3 / External alarm 3
BI: Motor stall monitoring enable (negated) / Mot stall enab neg
BI: RFG active / RFG active
BI: Technology controller enable / Tec_ctrl enable
BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
BI: Technology controller fixed value selection bit 1 / Tec_ctrl sel bit 1
BI: Technology controller fixed value selection bit 2 / Tec_ctrl sel bit 2
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
BI: Technology controller motorized potentiometer raise setpoint / Tec_ctrl mop raise
BI: Technology controller motorized potentiometer lower setpoint / Tec_ctrl mop lower
BI: Hold technology controller integrator / Tec_ctr integ hold
BI: Technology controller limiting enable / Tec_ctrl lim enab
BI: LR activate reference mark search / Ref_mark act
BI: LR activate measuring probe evaluation / MT_eval act
BI: LR selecting measuring probe evaluation / MT_eval select
BI: LR measuring probe evaluation edge / MT_eval edge
BI: LR pos. actual value preprocessing activate corr. value (edge) / ActVal_prepCorrAct
BI: LR activate position actual value setting / s_act setting act
BI: LR enable 1 / Enable 1
BI: LR enable 2 / Enable 2
BI: LR setpoint signal fixed / Mess setp fixed
BI: LR signal travel to fixed stop active / Signal TfS act
BI: LR signal fixed stop reached / Signal fixed stop
BI: LR signal traversing command active / Sig trav_cmnd act
BI: EPOS STOP cam activation / STOP cam act
BI: EPOS STOP cam minus / STOP cam minus
BI: EPOS STOP cam plus / STOP cam plus
BI: EPOS jerk limiting activation / Jerk limit act
BI: EPOS modulo correction activation / Modulo corr act
BI: EPOS software limit switch activation / SW lim sw act
BI: EPOS jog 1 signal source / Jog 1 S_src
BI: EPOS jog 2 signal source / Jog 2 S_src
BI: EPOS jogging incremental / Jog incr
BI: EPOS referencing start / Ref start
BI: EPOS set reference point / Set ref_pt

2.4 BICO parameters (connectors/binectors)

2 Parameters
709