SW4 -
ON = Only last minute warning tone will sound.
OFF = All progress tones will sound.
This enables the installer to disable all the progress tones (one per minute) except the last minute
shut down warning tone. This is beneficial for use in demo kits.
SW5 - ON = Enables the CENTRAL STATION DETECTION feature.
OFF = Disables the CENTRAL STATION DETECTION feature. This is recommended when the subscriber has
call waiting which cannot be disabled.
SW 6 - ON = Enables the AUTO TRIGGER FUNCTION.
OFF = Disables the AUTO TRIGGER FUNCTION. This is recommended when using a hard trigger from a control
panel.
SUMMARY OF SWITCH SETTINGS
SWITCH
1
2
3
5
3.3 WIRING AND PLACEMENT.
WIRE
BROWN
RED
ORANGE
YELLOW
BLUE
GRAY
BLACK
ON
FACTORY TEST
IMMEDIATE TURN ON
POSITIVE EDGE
ALL TONES ACTIVE
CENTRAL STATION DETECT
AUTO TRIP ON
CONNECTION
Negative supply input (GROUND)
(+
Positive supply input
Trigger input (see options)
Alarm active from control panel (Ground on alarm) see manual.
External siren input (-) (set P5 & P6, Section 6.1)
Common relay contact.
Normally open relay contact. Closed when audio active.
OFF
NORMAL
SET UP RING DETECT WINDOW
N E G A T I V E E D G E
LAST MINUTE TONE ONLY
D I S A B L E D
AUTO TRIP OFF
12 VDC)
4
P/N 1195 1 1 Rev. 2