Sign In
Upload
Manuals
Brands
IBM Manuals
Server
866561Y - Eserver xSeries 250
IBM 866561Y - Eserver xSeries 250 Manuals
Manuals and User Guides for IBM 866561Y - Eserver xSeries 250. We have
1
IBM 866561Y - Eserver xSeries 250 manual available for free PDF download: Hardware Maintenance Manual
IBM 866561Y - Eserver xSeries 250 Hardware Maintenance Manual (294 pages)
Models 1RY, 2RY
Brand:
IBM
| Category:
Server
| Size: 8.28 MB
Table of Contents
About this Manual
5
Important Safety Information
5
Online Support
6
IBM Online Addresses
6
Table of Contents
7
General Checkout
11
General Information
13
Features and Specifications
13
Server Features
15
Reliability, Availability, and Serviceability
16
Controls and Indicators
17
Information LED Panel
19
Diagnostics
21
Diagnostic Tools Overview
21
Post
22
POST Beep Codes
22
POST Error Messages
22
Event/Error Logs
22
Small Computer System Interface Messages
22
Solving Serveraid Problems
23
Serveraid Controller Messages
23
Serveraid Startup Messages
23
Serveraid ISPR, BCS, and ECS POST Error Codes
28
Rebuilding a Defunct Drive
32
Steps for Recovering from Defunct Drives
33
Rebuilding a Hot-Swap Drive
33
Recovering from an Incomplete Format of a Physical
33
Drive
33
Recovering from a Failure in a Failover-Environment
34
Replacing a Non-Hot-Plug Controller in a Failover Pair
34
Diagnostic Programs and Error Messages
34
Pair
34
Text Messages
35
Starting the Diagnostic Programs
35
Viewing the Test Log
36
Diagnostic Error Message Tables
37
Light Path Diagnostics
37
Power Supply Leds
37
Diagnostic Panel Leds
38
Light Path Diagnostics
39
Power Checkout
41
Temperature Checkout
41
Recovering BIOS
42
Replacing the Battery
42
Diagnosing Errors
44
Troubleshooting the Ethernet Controller
44
Network Connection Problems
44
Ethernet Controller Troubleshooting Chart
45
Ethernet Controller Messages
46
Novell Netware or Intranetware Server ODI Driver
47
Messages
47
NDIS 4.0 (Windows NT) Driver Messages
49
UNIX Messages
49
Configuring the Server
53
Using the Configuration/Setup Utility Program
53
Starting the Configuration/Setup Utility Program
53
Choices Available from the Configuration/Setup Main
54
Menu
54
Using Passwords
58
Power-On Password
58
Administrator Password
58
Using the Scsiselect Utility Program
59
Starting the Scsiselect Utility Program
59
Choices Available from the Scsiselect Menu
60
Installing Options
63
Major Components of the Netfinity 7600
63
Component Locations
64
I/O Board Component Locations
64
Processor Board Component Locations
65
Processor Board Leds
65
Processor Board Connectors
66
Processor Board Jumpers
67
Memory Board Component Locations
68
Memory Board Connectors
68
Memory Board LED Locations
70
Before You Begin
70
Working Inside the Server with the Power on
71
Removing the Server Top Cover and Bezel
71
Removing the Top Cover
72
Removing the Media-Bay Bezel
72
Removing the Front Trim Bezel
73
Working with Adapters
73
Adapter Considerations
74
Installing a Hot-Plug Adapter
74
Installing Internal Drives
76
Internal Drive Bays
77
Installing a Hot-Swap Hard Disk Drive
78
Installing a 5.25-Inch Removable-Media Drive
80
Installing Memory-Module Kits
81
Installing a Microprocessor Kit
83
Installing a Hot-Swap Power Supply
86
Replacing a Hot-Swap Fan
88
Completing the Installation
89
Installing the Front Trim Bezel
89
Installing the Media-Bay Bezel
89
Installing the Top Cover
90
Reconfiguring the Server
91
Connecting External Options
91
Input/Output Ports
91
Parallel Port
92
Viewing or Changing the Parallel-Port Assignments
92
Parallel Port Connector
93
Video Port
93
Keyboard Port
94
Auxiliary-Device (Pointing Device) Port
95
Ultra2 SCSI Ports
95
SCSI Cabling Requirements
96
Setting SCSI Ids
96
SCSI Connector Pin-Number Assignments
96
Serial Ports
97
Viewing or Changing the Serial-Port Assignments
97
Serial-Port Connectors
98
Universal Serial Bus Ports
98
USB Cables and Hubs
98
USB-Port Connectors
99
Ethernet Port
99
Configuring the Ethernet Controller
99
Failover for Redundant Ethernet
99
Ethernet Port Connector
102
Advanced System Management Ports
102
Cabling the Server
103
Installing the Server in a Rack
103
Netfinity Manager
105
Managing Your IBM Netfinity Server with Netfinity
105
Manager
106
Netfinity Manager Documentation
106
Netfinity Manager System Requirements
106
Netfinity Manager for OS/2 System Requirements
106
Netfinity Manager for Windows 95 and Windows 98 System Requirements
107
Netfinity Manager for Windows NT System
107
Requirements
107
Netfinity Manager for Windows 95 and Windows
107
System Requirements
107
Starting the Netfinity Manager Installation Program
108
Netfinity Manager Database Support
115
DB2 Database Support
115
System Requirements
115
Installing and Configuring the Database
115
Activating the Database
116
Granting and Revoking Database Privileges
117
Deleting the Database
119
Lotus Notes Database Support
119
System Requirements
119
Installing the Database
120
Browsing the Netfinity Manager Lotus Notes
121
Database
121
ODBC Database Support
121
System Requirements
121
ODBC Database Configuration
122
Creating the Netfinity Manager Tables
122
Supported and Certified Databases
124
Starting Netfinity Manager
125
Netfinity Manager Service Manager
126
Netfinity Manager Service Descriptions
127
Advanced System Management
128
Alert Manager
128
Alert on LAN Configuration
128
Capacity Management
128
Cluster Manager
128
Critical File Monitor
128
DMI Browser
129
ECC Memory Setup
129
Event Scheduler
129
File Transfer
129
Power-On Error Detect
129
Predictive Failure Analysis
129
Process Manager
129
RAID Manager
129
Remote Session
130
Remote System Manager
130
Remote Workstation Control
130
Screen View
130
Security Manager
130
Serial Connection Control
130
Service Configuration Manager
130
Software Inventory
131
System Diagnostics Manager
131
System Information Tool
131
System Monitor
131
System Partition Access
131
System Profile
131
Update Connector Manager
131
Web Manager Configuration
132
Delaying Netfinity Manager Startup on OS/2 Systems
132
Getting more Information about Netfinity Manager
132
Systems
132
Installation Options
133
Automated Installation
133
Customized Installation
135
FRU Information (Service Only)
137
Diagnostic Switch Card
137
Disconnecting the Shuttle
138
Front LED Card Assembly
138
I/O Legacy Board
139
Memory Card Removal
140
PCI Switch Card
142
Power Backplane Assembly
142
Processor/Pci Backplane
143
Removing the Shuttle
145
SCSI Backplane Assembly
145
SCSI Daughter Card
146
Installing and Configuring Serveraid Controllers
149
Features and Connector Locations of Serveraid-4H
149
Controller
149
Controller Features
149
Connector Locations
149
SCSI Channel Connectors
150
Features and Connector Locations of Serveraid-4L
151
Controller
151
Controller Features
151
Connector Locations
151
SCSI Channel Connector
151
Features and Connector Locations of Serveraid-4M
153
Controller
153
Controller Features
153
Connector Locations
153
SCSI Channel Connectors
153
Using a Serveraid-4X Controller in a Server with Hot
155
Plug PCI Features
155
Using Windows NT 4.0 with Hot-Plug PCI Features
155
Step 1: Installing and Cabling a Serveraid Controller
156
Installing the Serveraid Controller
156
Connecting External Devices
160
Step 2: Updating BIOS and Firmware Code
161
Step 3: Configuring Serveraid Controllers
161
Using the Serveraid Manager Program
162
Using Configuration Mode
164
Using Information Mode
172
Obtaining Serveraid Updates
172
Downloadable Files from the World Wide Web
173
Serveraid Device Driver Order on Windows 2000 and Windows NT 4.0
174
Using Utility Programs
175
Using the Serveraid Mini-Configuration Program
175
Viewing the Controller Status
176
Viewing the Configuration
176
Using the Advanced Configuration Functions
176
Using the IPSSEND Command-Line Program
178
Server Roll-Out Functions
178
Error-Recovery Functions
179
Problem-Isolation and Debug Functions
180
RAID Configuration Functions
183
Using the IPSMON Command-Line Program
183
Only)
183
Introduction to IBM Serveraid Cluster Solution
185
Solution
186
Checking the Ownership of a Physical Drive
187
Adding Logical Drives to a Cluster
187
Validating a Cluster
188
Viewing Merge Group Numbers and Other Cluster
190
Information
190
POST (ISPR) Error Codes and Procedures
190
Serveraid-4 Controller Error Codes/Messages
190
POST (ISPR) Error Codes
192
POST (ISPR) Error Procedures
192
Recovery Procedures for Defunct (DDD) Drives
194
Drive Replacement (Rebuilding a Defunct Drive)
194
Steps for Recovering from Defunct Drives
195
Rebuilding a Hot-Swap Drive
195
Recovering from an Incomplete Format of a Physical Drive
195
Recovering from a Failure in a Failover-Environment
196
Replacing a Non-Hot-Plug Controller in a Failover Pair
196
Guidelines for the Rebuild Operation
196
General Information about the Rebuild Operation
196
Automatically Rebuilding the Defunct Drive
197
Software and Physical Replacement
197
Using Serveraid Manager to Determine the Correct Order to Software Replace
197
Using and Understanding the Serveraid Monitor Log
198
Recovery from Serveraid Controller Failure
199
Recovery Procedures
199
Recovery Procedures for One Defunct Drive
200
More than One Defunct (DDD) Drive, All Logical Drives in Critical or OK State
200
More than One Defunct (DDD) Drive and One or more
200
Arrays Offline
200
Channel Record Table
201
Reference Information
202
Understanding RAID Technology
202
Stripe-Unit Size
203
Supported RAID Levels
203
Drive State Descriptions
212
Acronyms, Terms, and Definitions
220
Symptom-To-FRU Index
225
Beep Symptoms
225
No Beep Symptoms
228
Diagnostic Panel Leds
228
Diagnostic Error Codes
230
Error Symptoms
235
Power Supply LED Errors
235
POST Error Codes
236
Serveraid POST (ISPR) Error Codes
242
Serveraid POST (ISPR) Error Procedures
242
Serveraid
244
SCSI Error Codes
246
Temperature Error Messages
246
Fan Error Messages
247
Power Error Messages
247
System Shutdown
248
Power Related System Shutdown
248
Temperature Related System Shutdown
249
DASD Checkout
249
Host Built-In Self Test (BIST) Checkout
249
I2C Bus Fault Messages
249
Undetermined Problems
251
Parts Listing (Type 8665)
253
Part a
253
System
253
Part B
254
System
255
Keyboards
256
Power Cords
257
Related Service Information
259
Safety Information
259
General Safety
259
Electrical Safety
260
Safety Inspection Guide
261
Handling Electrostatic Discharge-Sensitive Devices
262
Grounding Requirements
263
Safety Notices (Multi-Lingual Translations)
263
Send Us Your Comments
289
Problem Determination Tips
290
Notices
290
Trademarks
291
Advertisement
Advertisement
Related Products
IBM 86607SU - Netfinity 5500 - 7SU
IBM 86604RU - Netfinity 5500 - 4RU
IBM 866251Y - Netfinity 5500 M20
IBM 86626RY - Netfinity 5500 M20
IBM 86625RY - Netfinity 5500 M20
IBM 86655RY - Netfinity 7600 - 8665
IBM 866631Y - Netfinity 7100 - 8666
IBM 8668 - Eserver xSeries 232
IBM 866011U - Netfinity 5500 - 8660
IBM 86601RU - Netfinity 5500 - 1RU
IBM Categories
Server
Desktop
Storage
Laptop
Monitor
More IBM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL