Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
Notifier AFP-100
User Manuals: Honeywell Notifier AFP-100 Control Panel
Manuals and User Guides for Honeywell Notifier AFP-100 Control Panel. We have
1
Honeywell Notifier AFP-100 Control Panel manual available for free PDF download: Wiring Manual
Honeywell Notifier AFP-100 Wiring Manual (80 pages)
Intelligent Control Panel SLC
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.84 MB
Table of Contents
Table of Contents
5
Section 1: Introduction
8
About this Manual
8
UL 864 Compliance
8
1: Products Subject to AHJ Approval
8
Reference Documentation
9
SLC Overview
11
Polling Protocols
11
1: Available Protocols
11
2: Protocol Use
12
Devices
12
1: Monitor/Zone Interface Module
12
2: Control Modules
12
3: Isolator Modules
12
4: Relay Modules
13
5: Multiple Input/Output Modules
13
6: Transponders
13
7: Plug-In Detector Bases
13
8: Intelligent Detectors
13
9: Addressable Manual Pull Stations
14
10: Wireless Interface
14
11: ACPS-610 Addressable Charger/Power Supply
14
12: ACPS-2406 Addressable Charger/Power Supply
14
13: AMPS-24 Addressable Power Supply
14
SLC Capacity
15
SLC Performance
15
LED Operation
15
Section 2: Wiring Requirements
16
Recommended SLC Wiring
16
Two-Wire SLC - Style 4 (Class B)
17
1: Measuring Loop Resistance
17
2: Measuring Total Wire Length
18
Four-Wire SLC Style 6 & 7 (Class A)
18
1: Measuring Loop Resistance
18
2: Measuring Total Wire Length
19
Control Panel Terminal Blocks
19
1: NFS2-3030 and NFS-3030 with LCM-320, LEM-320
19
2: NFS2-640 with Loop Expander Modules, NFS-320 and NFS-320SYS
20
3: NFS-640 with Loop Expander Modules
20
4: Afp-100
20
5: Afp-200
20
6: Afp-300/Afp-400
21
7: AM2020/AFP1010 with LIB-200A or LIB-400
21
8: System 5000 with AIM-200
21
Section 3: Shielded Wire Termination
22
Overview
22
No Conduit
22
Full Conduit
22
Partial Conduit
23
Floating Shield
23
Section 4: SLC Circuits Without Isolators
24
Overview
24
NFPA Style 4 SLC
24
NFPA Style 6 SLC
25
Section 5: SLC Circuits with Isolators
26
Overview
26
Fault Isolator Modules
26
Isolator Detector Bases
27
1: How an Isolator Base Works
27
NFPA Style 4 SLC Using Isolator Modules
29
NFPA Style 6 SLC Using Isolator Modules
31
NFPA Style 7 SLC Using an Isolating Device
32
Section 6: Monitor Modules
33
Description
33
1: Addressable Monitor Module
33
2: Zone Interface Module
33
3: Miniature Monitor Module
34
4: FMM-4-20 4-20Ma Monitor Module
34
Setting an SLC Address for a Module
35
NFPA Style B IDC Using Monitor Modules
35
NFPA Style D IDC Using Monitor Modules
36
NFPA Style B IDC Using Zone Interface Modules
37
NFPA Style D IDC Using Zone Interface Modules
38
Section 7: Control Modules
40
Description
40
1: Setting an SLC Address
40
Wiring a NAC with Addressable Control Modules
40
1: Wiring a Solenoid with the FCM-1-REL
41
Wiring a Style y NAC (Two-Wire) with Addressable Control Modules
41
Wiring a Style Z NAC (Four-Wire) with Addressable Control Modules
42
Connecting a Releasing Device to the Addressable Control Module
43
Section 8: Relay Module
44
Description
44
1: Setting an SLC Address
44
Wiring the Addressable Relay Module (Form-C Relay)
44
Section 9: Multiple Input/Output Modules
45
Description
45
1: Fdm-1
45
2: Fdrm-1
45
Setting the SLC Address
45
Wiring the Dual Monitor Module
45
Wiring the Addressable Dual Monitor/Dual Relay Module
46
NFPA Style B IDC Wiring Using Dual Monitor Modules
46
Section 10: Intelligent Detectors, Intelligent Detector Bases, and Wireless Gateway
48
Description
48
1: Intelligent Detector Bases
48
2: Intelligent Aspiration Detectors
48
3: Wireless Gateway
48
Wiring a Detector Base
49
Wiring an Isolator Base
51
Wiring a Relay Base
51
Wiring a Sounder Base
52
Wiring and Programming Aspiration Detectors
52
Wiring the FWSG
54
1: SLC Connections
54
Power Connections: Powered by the SLC
55
1: Power Connections: External, Regulated +24 VDC Power Source
56
Section 11: Addressable Manual Pull Station
57
Description
57
1: Setting an SLC Address
57
Wiring a Manual Pull Station
57
Appendix A: Power Considerations
58
A.1: Supplying Power to 24 VDC Detectors and Nacs
58
A.2: Supervising 24 VDC Power
58
A.2.1: Using Type Codes with Built-In Power Supervision on the NFS2-3030, NFS-3030, NFS2-640, NFS-320 and NFS-320SYS
58
A.2.2: Power Supervision Relay
58
A.2.3: Using the Addressable Control Module Without Relay
60
Appendix B: SLC Surge Suppression
62
B.1: Introduction
62
B.2: Installation
62
B.2.1: Afp-100 & Afp-200
63
B.2.2: Afp-300, Afp-400
63
B.2.3: AM2020 & AFP1010(LIB-200A or LIB-400)
64
B.2.4: NFS2-3030, NFS-3030, NFS2-640, NFS-640, NFS-320, and NFS-320SYS
65
Appendix C: Terminal Conversion Charts for V-Type and H-Type Devices
67
C.1: Frm-1
67
C.2: FCM-1 and FZM-1
68
C.3: Fmm-1
68
C.4: Ftm-1
68
C.5: Fdm-1
69
Appendix D: Intelligent Detector Base Layouts for Legacy Devices
70
D.1: Wiring a Detector Base
70
D.2: Wiring an Isolator Base
71
D.3: Wiring a Relay Base
71
D.4: Wiring a Sounder Base
72
Appendix E: Canadian Versions of SLC Devices
73
Index
76
Advertisement
Advertisement
Related Products
Honeywell Notifier AFP-3030
Honeywell Notifier AFP-200
Honeywell Notifier AFP-300
Honeywell Notifier AFP-400
Honeywell Notifier AFP1010
Honeywell AQ252 Series
Honeywell Fire-Lite Alarms ACC-25/50
Honeywell Fire-Lite Alarms ACC-25/50ZS
Honeywell NOTIFIER AM1000
Honeywell AQ25742B
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL