Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
Fire-Lite Alarms MS-9050UDC
Honeywell Fire-Lite Alarms MS-9050UDC Manuals
Manuals and User Guides for Honeywell Fire-Lite Alarms MS-9050UDC. We have
2
Honeywell Fire-Lite Alarms MS-9050UDC manuals available for free PDF download: Manual, Wiring Manual
Honeywell Fire-Lite Alarms MS-9050UDC Manual (216 pages)
Addressable Fire Alarm Control Panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 2.75 MB
Table of Contents
Table of Contents
4
Product Description
12
Features and Options
12
Specifications
13
Current Availability
14
Controls and Indicators
15
Circuits
15
Digital Alarm Communicator/Transmitter
16
Components
17
Intelligent Addressable Detectors: Newer Series
17
Intelligent Addressable Modules: Newer Series
17
Series Intelligent Addressable Devices
17
Device Accessories
17
Optional Modules
18
Accessories
18
PK-CD Programming Utility
18
Dress Panel
18
Trim Ring
18
Battery Box
19
Battery Charger
19
CHG-120F Battery Charger
19
ANN-BUS Devices
20
ANN-BUS Wiring
20
Calculating Wiring Distance for ANN-BUS Modules
20
Wiring Configuration
22
Powering ANN-BUS Devices from Auxiliary Power Supply
23
ANN-BUS Device Addressing
23
Remote Fire Annunciator
24
Specifications
24
Installation
24
Mounting
24
Opening/Closing Annunciator
24
Wiring ANN-80 to FACP
25
ANN-S/PG Serial/Parallel Interface Module
27
Specifications
27
PRN-6F Printer Installation
27
Connecting PRN-6F Printer
28
Setting Printer Options
28
ANN-I/O LED Driver Module
29
ANN-I/O Board Layout
29
Specifications
29
ANN-I/O Connection to FACP
30
ANN-I/O Module LED Wiring
31
ANN-LED Annunciator Module
32
ANN-LED Board Layout
32
Specifications
32
ANN-LED Connection to FACP
33
ANN-RLY Relay Module
34
ANN-RLY Board Layout
34
Specifications
34
Mounting/Installation
34
ANN-RLY Connection to FACP
35
Getting Started
35
Telephone Requirements and Warnings
36
Telephone Circuitry
36
Digital Communicator
36
Telephone Company Rights and Warnings
37
For Canadian Applications
38
Installation
39
Mounting Backbox
39
Mounting Chassis/Transformer/Main Circuit Board
40
Power
43
AC Power and Earth Ground Connection
43
Battery Power
43
Relays
44
Notification Appliance Circuits
44
Configuring Nacs
45
UL Power-Limited Wiring Requirements
46
Digital Communicator
47
Optional Modules/Accessories Installation
48
4XTMF Transmitter Module Installation
48
Programming
51
Programming Data Entry
51
User Programming
52
Initial Power-Up
53
Programming Screens Description
53
Programming and Passwords
53
Master Programming Level
55
Autoprogram
56
Point Program
57
Detector Programming
57
Add Detector
57
Delete Detector
58
Edit Detector
58
Module Programming
67
Add Module
67
Delete Module
68
Edit Module Screen for Monitor Module
68
Edit Module Screen for Control Modules
77
Zone Setup
84
Enable
84
Disable
85
Zone 17, 18 and 19
85
Zones Installed
86
Zones Enabled
86
Zones Disabled
86
Zone Type
86
Zones Available
88
Loop Setup
88
Style
88
Loop Protocol
88
System Setup
89
Trouble Reminder
90
Banner
90
Time-Date
91
Time
91
Date
92
Clock Format
92
Daylight Savings Time
92
Timers
93
PAS (Positive Alarm Sequence) Delay
93
Presignal Delay
94
Waterflow Delay
94
AC Loss Delay
95
NAC (Notification Appliance Circuit)
95
Enabled
96
Type
97
Silenceable
97
Auto Silence
98
Coding (Only for Nacs Not Programmed as Sync Strobe Type)
98
Zone
100
Silence Inhibited
100
Sync Type
100
Relays
101
Canadian Option
102
Waterflow Silenceable
102
Verify Loop
102
History
103
View Events
103
Erase History
103
Walktest
104
Option Modules
105
Ann-Bus
106
ANN-BUS Enabled
106
Modules Installed
106
Auto-Configure
116
ANN-S/PG (Print) Options Screen
116
Options Screen
117
Onboard DACT
118
Onboard DACT Enable
118
Primary Phone
118
Secondary Phone
119
Central Station
120
Trouble Call Limit (Dialer Runaway Prevention)
121
Manual Dial Mode
133
Password Change
134
Clear Program
135
Program Check
136
Maintenance Programming Level
138
Disable Point
139
History
140
Program Check
141
Walktest
142
System
143
Zone Setup
144
Operating Instructions
147
Panel Control Buttons
147
Acknowledge/Step
147
Alarm Silence
147
Drill/Hold 2 Sec
147
Reset
147
Status Indicators and Leds
148
Normal Operation
149
Trouble Operation
149
Alarm Operation
151
Supervisory Operation
152
Process Monitor Operation
153
Hazard/Tornado Condition Operation
153
Medical Alert Condition Operation
153
NAC Operation
153
Programmed Zone Operation
154
Disable/Enable Operation
154
Waterflow Circuits Operation
154
Detector Functions
154
Time Functions: Real-Time Clock
154
Synchronized NAC Operation
155
Coded Operation
155
Presignal
155
Positive Alarm Sequence
156
Special System Timers
157
Silence Inhibit Timer
157
Autosilence Timer
157
Trouble Reminder
157
Waterflow Retard Timer
157
Alarm Verification (None or One Minute)
158
Walktest
158
Read Status
159
System Point
160
Zones
161
Power
162
Trouble Reminder
163
Timers
163
Nac
164
Relays
164
Program Check
165
History
165
Ann-Bus
166
Phone Line
167
Central Station
167
Service Terminal
168
Print
168
Time-Date
170
Central Station Communications
171
Transmittal Priorities
174
Local/Remote Site Upload/Download
176
Remote Download
176
Transferring a Program
177
Security Features
178
Power Supply Calculations
179
Overview
179
Calculating the AC Branch Circuit
179
Calculating the System Current Draw
180
Overview
180
How to Use Table 7.3 on Page 181 to Calculate System Current Draw
180
Calculating the Battery Size
182
NFPA Battery Requirements
182
Selecting and Locating Batteries
182
Software Zones
183
Correlations
183
Default Programming
188
NFPA Standard-Specific Requirements
189
Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts
193
Municipal Box Trip - Silenceable
194
FACP with Keltron
195
Wire Requirements
196
NAC Wiring
197
HVAC Control
198
Control Module Operation
198
Hvac Shutdn
198
Monitor Module Operation
198
Hvac Restart
198
Hvac Ovrride
199
Ademco Contact ID Format Event Code Descriptions
200
Transmission Format between DACT and Receiver
200
Ademco Contact ID Typical Printout
200
Canadian Application
205
ANN-LED Annunciator Installation for Canadian Applications
205
AC Power Connections for Canadian Applications
206
Advertisement
Honeywell Fire-Lite Alarms MS-9050UDC Wiring Manual (80 pages)
Intelligent Control Panel, SLC
Brand:
Honeywell
| Category:
Control Panel
| Size: 3.06 MB
Table of Contents
Table of Contents
5
Section 1: Introduction
8
Scope
8
1: Reference Documentation
8
Overview
10
Polling Protocols
10
1: Available Protocols
10
2: Protocol Use
10
Devices
10
1: Isolator Modules
10
2: Monitor Modules
10
3: Control Modules
11
4: Relay Modules
11
5: Multiple Input/Output Modules
11
6: Intelligent Detectors
11
Manual Pull Station
12
8: Wireless Gateway
12
9: 300 Series Addressable Devices
12
10: 900 Series Addressable Devices
12
SLC Capacity
12
SLC Performance
12
Surge Suppression
13
LED Operation
13
Section 2: Wiring Requirements
14
Wire Sizing
14
1: CLIP (Classic Loop Interface Protocol) Mode
14
2: Litespeed Mode
14
Measuring Resistance & Length
14
1: Two-Wire SLC - Class B
14
2: Four-Wire SLC Class a and Class X
15
Shield Wire Termination
16
Control Panel Terminal Blocks
17
1: Ms-9200
17
2: Ms-9600, Ms-9600Ls, & Ms-9600Udls
17
3: MS-9200UDLS (Software Version 3.0)
18
4: MS-9200UD & MS-9200UDLS (Versions 1 and 2)
18
5: Ms-9050Ud
18
6: Es-50X
19
7: Es-200X
19
Section 3: SLC Circuits Without Isolators
20
Overview
20
NFPA Class B SLC
20
NFPA Class a SLC
21
Section 4: SLC Circuits with Isolators
22
Fault Isolator Devices
22
1: Isolating an SLC Branch
22
2: Wiring an Isolator Module
22
NFPA Class B SLC Using Isolator Modules
24
NFPA Class a SLC Using Isolator Modules
26
NFPA Class X SLC Using Isolator Modules
27
Section 5: Monitor Modules
28
Descriptions
28
1: Addressable Monitor Modules
28
2: Zone Interface Modules
30
3: Dual Monitor Module
32
4: Mini Monitor Module
32
Installation
32
1: Setting an SLC Address for a Single Point Module
33
2: Setting an SLC Address for a Multi-Point Module
33
MMF-300 Wiring Diagrams
34
1: Wiring a NFPA Class B IDC with an MMF-300
34
2: Wiring a NFPA Class a IDC with an MMF-300
35
3: MMF-300 Wiring for Emergency Alarm System Applications
36
MMF-300-10 Wiring Diagrams
37
1: Wiring a NFPA Class B IDC with an MMF-300-10
37
2: Wiring a NFPA Class a IDC with an MMF-300-10
38
MDF-300 Wiring Diagrams
39
1: Wiring a NFPA Class B IDC with an MDF-300
39
MMF-302 Wiring Diagrams
40
1: Wiring a NFPA Class B IDC with an MMF-302
40
2: Wiring a NFPA Class a IDC with an MMF-302
41
MMF-302-6 Wiring Diagrams
42
1: Wiring a NFPA Class B IDC with an MMF-302-6
42
2: Wiring a NFPA Class a IDC with an MMF-302-6
43
Section 6: Control Modules
44
Description
44
CMF-300 Installation
44
1: Setting an SLC Address for a CMF-300 Module
44
2: Wiring a Notification Appliance Circuit (NAC) with a CMF-300
44
Wiring a CMF-300 Module
44
1: Wiring a Class B NAC (Two-Wire) with Addressable Control Modules
44
2: Wiring a Class a NAC (Four-Wire) with Addressable Control Modules
45
CMF-300-6 Installation
46
1: Cabinet Installation
46
2: Setting an SLC Address for an CMF-300-6 Module
46
3: Setting Nacs as Class B or Class a
46
4: Disabling Unused Module Addresses
46
5: Short Circuit Protection
46
6: Features Not Supported
46
7: Circuit Board Information
47
Wiring a CMF-300-6 Module
48
1: Wiring a Class B NAC (Two-Wire)
48
2: Wiring a Class a NAC (Four-Wire)
49
Section 7: Relay Modules
50
Description
50
CRF-300 Installation & Wiring
50
1: Setting an SLC Address for a CRF-300 Module
50
2: Wiring a CRF-300 Module (Form-C Relay)
50
CRF-300-6 Circuit Board Information
51
CRF-300-6 Installation & Wiring
52
1: Cabinet Installation
52
2: Setting an SLC Address for a CRF-300-6 Module
52
3: Disabling Unused Module Addresses
52
4: Wiring a CRF-300-6 Module (Form-C Relay)
52
Section 8: Multiple Input/Output Modules
53
Description
53
CDRM-300 Installation & Wiring
53
1: Setting an SLC Address for a CDRM-300 Module
53
2: Wiring a CDRM-300 Module (Form-C Relay)
53
Section 9: Intelligent Detector Bases and Wireless Gateway
54
Description
54
Setting the Detector Address
54
Wiring a Detector Base
55
Wiring an Isolator Base
56
Wiring a Relay Base
56
Wiring a Sounder Base
57
Wiring the W-GATE
57
1: SLC Connections
58
2: W-GATE Powered by the SLC
58
3: W-GATE Powered by a Regulated, External +24VDC Power Source
59
Section 10: Addressable Beam Detectors
60
Description
60
Installation and Wiring
60
1: Setting an SLC Address for a Beam Detector
60
2: Wiring a Beam Detector
60
Section 11: Addressable Manual Pull Station
62
Description
62
Installation
62
1: Setting an SLC Address
62
2: Wiring a Manual Pull Station
62
Appendix A: Power Considerations
63
A.1: Supplying Power to 24 VDC Detectors and Nacs
63
A.1.1: Resistance and Size
63
A.2: Supervising 24 VDC Power
64
Appendix B: Surge Suppression
65
B.1: Introduction
65
B.2: Installation
65
B.2.1: Wiring Diagram for MS-9200
66
B.2.2: Wiring Diagram for MS-9600, MS-9600LS, MS-9600UDLS, MS-9200UD, MS-9200UDLS, and MS-9050UD
67
B.2.3: Wiring Diagram for ES-50X and ES-200X
68
Appendix C: Terminal Conversion Charts for New & Legacy Devices
69
C.1: Crf-300
69
C.2: CMF-300 and MMF-302
69
C.3: Mmf-300
70
C.4: Mdf-300
71
Appendix D: Intelligent Detector Base Layouts for Legacy Devices
72
D.1: B350LP or B501 Detector Base
72
D.2: B224BI Isolator Base
73
D.3: B224RB Relay Base
73
D.4: B501BH(-2) and B501BHT(-2) Sounder Bases
74
Appendix E: Canadian Versions of SLC Devices
75
Index
77
Advertisement
Related Products
Honeywell Fire-Lite Alarms MS-9050UD
Honeywell Fire-Lite Alarms MS-9050UDE
Honeywell Fire-Lite Alarms MS-9200
Honeywell Fire-Lite Alarms MS-9200E
Honeywell Fire-Lite Alarms MS-9600
Honeywell Fire-Lite Alarms MS-9600LS
Honeywell Fire-Lite Alarms MS-9600LSC
Honeywell Fire-Lite Alarms MS-9600UDLS
Honeywell Fire-Lite Alarms MS-9600UDLSE
Honeywell Fire-Lite Alarms MS-9200UD
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL