Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
Fire-Lite Alarms ES-50X
Honeywell Fire-Lite Alarms ES-50X Manuals
Manuals and User Guides for Honeywell Fire-Lite Alarms ES-50X. We have
4
Honeywell Fire-Lite Alarms ES-50X manuals available for free PDF download: Manual, Wiring Manual
Honeywell Fire-Lite Alarms ES-50X Manual (168 pages)
Addressable Fire Alarm Control Panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 3.23 MB
Table of Contents
Table of Contents
5
Section 1: Product Description
13
Features and Options
13
Specifications
14
Controls and Indicators
15
Components
16
1: Intelligent Addressable Detectors
17
2: Intelligent Addressable Modules
17
3: Addressable Device Accessories
17
End-Of-Line Resistor Assembly
17
Power Supervision Relay
17
EOL-C(R/W) Mounting Plate
17
Optional Modules
17
Accessories
17
1: FS-Tools Programming Utility
17
2: Dress Panel
18
3: Trim Ring
18
4: Battery Box
18
5: Battery Charger
18
CHG-120F Battery Charger
18
6: W-GATE(A) Wireless Gateway
18
7: ANN-BUS Annunciators/Modules
19
Guidelines
19
And ANN-100 Remote Fire Annunciators
19
ANN-S/PG Serial/Parallel Interface Module
19
ANN-I/O LED Driver Module
19
ANN-LED Annunciator Module
19
ANN-RLY Annunciator Module
19
Getting Started
20
Telephone Requirements and Warnings
20
1: Telephone Circuitry
20
2: Telephone Company Rights and Warnings
20
3: for Canadian Applications
21
Section 2: Installation
22
Mounting the Backbox
22
Power
25
1: AC Power and Earth Ground Connection
25
2: Battery Power
25
3: Special Application DC Power Output Connection
26
Relays
26
Notification Appliance Circuits
26
1: Class B NAC Wiring
27
2: Class a NAC Wiring
27
Remote Synchronization Output
28
UL Power-Limited Wiring Requirements
29
IPOTS-COM Communicator
30
Wiring
30
Dip Switches
30
Optional Module Installation
31
1: Cell-Mod(C)/Cell-Cab-Fl
31
Installation
31
Wiring
31
2: 4XTMF Transmitter Module Installation
31
3: ANN-BUS Annunciators/Modules
33
ANN-BUS Wiring
33
ANN-BUS Device Addressing
36
Remote Fire Annunciator
36
Remote Fire Annunciator
38
ANN-S/PG Serial/Parallel Interface Module
39
ANN-I/O LED Driver Module
41
ANN-LED Annunciator Module
43
ANN-RLY Annunciator Module
45
4: Printer
46
Printer Configuration
46
5: W-GATE(A) Wireless Gateway
47
Section 3: Programming
48
User Programming
49
Programming Screens Description
49
Initial Power-Up
49
Users and Passwords
49
1: Administrator Role
50
Password Change-Administrator
50
Password Change- User
51
Assign Role
52
2: User Role
53
Master Programming Level
53
1=Autoprogram
54
2: Point Program
55
Detector Programming
55
Module Programming
61
3=Zone Setup
69
Enable
69
Disable
69
Special Purpose Zone
70
Zones Installed
70
Zones Enabled
70
Zones Disabled
71
Zone Type
71
Zones Available
71
4: Loop Setup
72
Class
72
Loop Protocol
72
Device Addressing
72
5: System Setup
72
Function Keys
73
Banner
73
Time-Date
74
Timers
75
NACS (Notification Appliance Circuits)
77
Relays
80
Canadian Option
81
Waterflow Silenceable
81
Auxiliary Power
81
Trouble Reminder
82
Language
82
Charger Enable
82
4XTMF Supervision
82
Remote Sync Enable
82
6: History
82
View Events
82
Erase History
83
7: Communicator
83
Communicator Installed
83
POTS Settings
83
IP Settings
84
Primary and Secondary Communication Paths
85
Trouble Report Limit (Dialer Runaway Prevention)
88
Report Style
88
Event Codes
88
8: Annunciators
91
ANN-BUS Setup
91
ANN-BUS Options
98
9: Password Change
100
Invalid Password
100
Incorrect Password/Timeout
100
10: Clear Program
101
11: Program Check
101
Maintenance Programming Level
102
1: Disable Point
102
2=History
102
3=Program Check
103
4: Walktest
104
5: System
104
6: Zone Setup
105
Section 4: Operating Instructions
107
Panel Control Buttons
107
1: Acknowledge
107
2: Alarm Silence
107
3: Drill/Hold 2 Sec
107
4: Reset
107
5: Function Keys F1-F4
107
LED Indicators
107
Normal Operation
108
Trouble Operation
108
Alarm Operation
109
CO Alarm Operation
110
Supervisory Operation
110
Process Monitor Operation
111
Hazard/Tornado Condition Operation
111
Medical Alert Condition Operation
111
NAC Operation
112
Programmed Zone Operation
112
Disable/Enable Operation
112
Waterflow Circuits Operation
112
Detector Functions
112
Time Functions: Real-Time Clock
112
Synchronized NAC Operation
112
Coded Operation
113
Presignal
113
Positive Alarm Sequence
113
Special System Timers
114
1: Silence Inhibit Timer
114
2: Autosilence Timer
114
3: Trouble Reminder
114
4: Waterflow Retard Timer
114
5: Alarm Verification (None or One Minute)
114
6: Control Module Delay Timer
114
Walktest
114
Read Status
115
1=System Point
115
2=Zones
116
3: Trouble Reminder
116
4: Timers
117
5: Nacs
117
6: Relays
117
7: Program Check
117
8: History
117
9: Annunciators
118
10: Communicator
118
11: Print
119
Chamber Value
120
Drift Compensation
120
Maintenance Alert
120
12: Time-Date
121
13: Battery Charger
121
14: 4XTM Supervision
121
15: Remote Sync
121
Section 5: Central Station Communications - POTS Transmission
122
Transmittal Priorities
122
Section 6: FS-Tools Upload/Download
124
FS-Tools Up/Download
124
Transferring a Program
124
1: Security Features
125
Secret Code Verification
125
Time-Out at Control Panel
125
Error Checking
125
Central Station Data Protection
125
Section 7: USB Upload/Download
126
USB Upload/Download
126
Section 8: Firmware Upgrade
128
Firmware Upgrade
128
Section 9: Power Supply Calculations
130
Overview
130
Calculating the AC Branch Circuit
130
Calculating the System Current Load
130
2: How to Calculate System Current Load
130
Calculating the Battery Size
132
1: NFPA Battery Requirements
132
2: Selecting and Locating Batteries
132
Appendix A: Software Zones
133
A.1: Correlations
133
Appendix B: Default Programming
138
Appendix C: NFPA Standard-Specific Requirements
139
C.1: MBT-1 Municipal Box Trip - Silenceable
142
Appendix D: Wire Requirements
143
D.1: NAC Wiring
144
Appendix E: HVAC Control
145
E.1: Control Module Operation
145
E.1.1: Hvac Shutdown
145
E.2: Monitor Module Operation
146
E.2.1: Hvac Restart
146
E.2.2: Hvac Ovrride
146
Appendix F: Ademco Contact ID Format Event Code Descriptions
147
F.1: Transmission Format between DACT and Receiver
147
F.2: Ademco Contact ID Typical Printout
147
Appendix G: Central Station Points
152
Appendix H: NFPA Requirements
153
Appendix I: Open/Short/Ground Trip Values
154
Appendix J: Canadian Application
155
Index
158
Slide-In Labels
163
Advertisement
Honeywell Fire-Lite Alarms ES-50X Manual (162 pages)
Addressable Fire Alarm Control Panel
Brand:
Honeywell
| Category:
Control Panel
| Size: 3.23 MB
Table of Contents
Table of Contents
5
Section 1: Product Description
12
Features and Options
12
Specifications
13
Controls and Indicators
14
Components
15
1: Intelligent Addressable Detectors
16
2: Intelligent Addressable Modules
16
3: Addressable Device Accessories
16
End-Of-Line Resistor Assembly
16
Power Supervision Relay
16
EOL-C(R/W) Mounting Plate
16
Optional Modules
16
Accessories
16
1: FS-Tools Programming Utility
16
2: Dress Panel
17
3: Trim Ring
17
4: Battery Box
17
5: Battery Charger
17
CHG-120F Battery Charger
17
6: W-GATE Wireless Gateway
17
7: ANN-BUS Annunciators/Modules
18
Guidelines
18
And ANN-100 Remote Fire Annunciators
18
ANN-S/PG Serial/Parallel Interface Module
18
ANN-I/O LED Driver Module
18
ANN-LED Annunciator Module
18
ANN-RLY Annunciator Module
18
Getting Started
19
Telephone Requirements and Warnings
19
1: Telephone Circuitry
19
2: Telephone Company Rights and Warnings
19
3: for Canadian Applications
20
Section 2: Installation
21
Mounting the Backbox
21
Power
24
1: AC Power and Earth Ground Connection
24
2: Battery Power
24
3: Special Application DC Power Output Connection
25
Relays
25
Notification Appliance Circuits
25
1: Class B NAC Wiring
26
2: Class a NAC Wiring
26
Remote Synchronization Output
27
UL Power-Limited Wiring Requirements
28
IPOTS-COM Communicator
29
Wiring
29
Dip Switches
29
Optional Module Installation
30
1: Cell-Mod(C)/Cell-Cab-Fl
30
Installation
30
Wiring
30
2: 4XTMF Transmitter Module Installation
30
3: ANN-BUS Annunciators/Modules
32
ANN-BUS Wiring
32
ANN-BUS Device Addressing
35
Remote Fire Annunciator
35
Remote Fire Annunciator
37
ANN-S/PG Serial/Parallel Interface Module
38
ANN-I/O LED Driver Module
40
ANN-LED Annunciator Module
42
ANN-RLY Annunciator Module
44
4: Printer
45
Printer Configuration
45
5: W-GATE Wireless Gateway
46
Section 3: Programming
47
User Programming
48
Initial Power-Up
48
Programming Screens Description
49
Programming and Passwords
49
Master Programming Level
50
1=Autoprogram
50
2=Point Program
50
Detector Programming
51
Module Programming
57
3=Zone Setup
65
Enable
65
Disable
65
Special Purpose Zone
66
Zones Installed
66
Zones Enabled
66
Zones Disabled
67
Zone Type
67
Zones Available
67
4: Loop Setup
68
Class
68
Loop Protocol
68
Device Addressing
68
5: System Setup
68
Function Keys
69
Banner
69
Time-Date
70
Timers
71
NACS (Notification Appliance Circuits)
73
Relays
76
Canadian Option
77
Waterflow Silenceable
77
Auxiliary Power
77
Trouble Reminder
78
Language
78
Charger Enable
78
4XTMF Supervision
78
Remote Sync Enable
78
6: History
78
View Events
78
Erase History
79
7: Communicator
79
Communicator Installed
79
POTS Settings
79
IP Settings
80
Primary and Secondary Communication Paths
81
Trouble Report Limit (Dialer Runaway Prevention)
84
Report Style
84
Event Codes
84
8: Annunciators
87
ANN-BUS Setup
87
ANN-BUS Options
94
9: Password Change
96
Invalid Password
96
10: Clear Program
97
11: Program Check
97
Maintenance Programming Level
98
1: Disable Point
98
2=History
99
3=Program Check
99
4: Walktest
100
5: System
101
6: Zone Setup
102
Section 4: Operating Instructions
103
Panel Control Buttons
103
1: Acknowledge
103
2: Alarm Silence
103
3: Drill/Hold 2 Sec
103
4: Reset
103
5: Function Keys F1-F4
103
LED Indicators
103
Normal Operation
104
Trouble Operation
104
Alarm Operation
105
CO Alarm Operation
106
Supervisory Operation
106
Process Monitor Operation
107
Hazard/Tornado Condition Operation
107
Medical Alert Condition Operation
107
NAC Operation
108
Programmed Zone Operation
108
Disable/Enable Operation
108
Waterflow Circuits Operation
108
Detector Functions
108
Time Functions: Real-Time Clock
108
Synchronized NAC Operation
108
Coded Operation
109
Presignal
109
Positive Alarm Sequence
109
Special System Timers
110
1: Silence Inhibit Timer
110
2: Autosilence Timer
110
3: Trouble Reminder
110
4: Waterflow Retard Timer
110
5: Alarm Verification (None or One Minute)
110
6: Control Module Delay Timer
110
Walktest
110
Read Status
111
1=System Point
111
2=Zones
112
3: Trouble Reminder
112
4: Timers
113
5: Nacs
113
6: Relays
113
7: Program Check
113
8: History
113
9: Annunciators
114
10: Communicator
114
11: Print
115
Chamber Value
116
Drift Compensation
116
Maintenance Alert
116
12: Time-Date
117
13: Battery Charger
117
14: 4XTM Supervision
117
15: Remote Sync
117
Section 5: Central Station Communications - POTS Transmission
118
Transmittal Priorities
118
Section 6: FS-Tools Upload/Download
120
FS-Tools Up/Download
120
Transferring a Program
120
1: Security Features
121
Secret Code Verification
121
Time-Out at Control Panel
121
Error Checking
121
Central Station Data Protection
121
Section 7: USB Upload/Download
122
USB Upload/Download
122
Section 8: Firmware Upgrade
124
Firmware Upgrade
124
Section 9: Power Supply Calculations
125
Overview
125
Calculating the AC Branch Circuit
125
Calculating the System Current Load
125
2: How to Calculate System Current Load
125
Calculating the Battery Size
127
1: NFPA Battery Requirements
127
2: Selecting and Locating Batteries
127
Appendix A: Software Zones
128
A.1: Correlations
128
Appendix B: Default Programming
133
Appendix C: NFPA Standard-Specific Requirements
134
C.1: MBT-1 Municipal Box Trip - Silenceable
137
Appendix D: Wire Requirements
138
D.1: NAC Wiring
139
Appendix E: HVAC Control
140
E.1: Control Module Operation
140
E.1.1: Hvac Shutdown
140
E.2: Monitor Module Operation
141
E.2.1: Hvac Restart
141
E.2.2: Hvac Ovrride
141
Appendix F: Ademco Contact ID Format Event Code Descriptions
142
F.1: Transmission Format between DACT and Receiver
142
F.2: Ademco Contact ID Typical Printout
142
Appendix G: Central Station Points
147
Appendix H: NFPA Requirements
148
Appendix I: Open/Short/Ground Trip Values
149
Appendix J: Canadian Application
150
Index
153
Slide-In Labels
157
50X and ES-50XC Fire Alarm Control Panels Operating Instructions
159
Honeywell Fire-Lite Alarms ES-50X Wiring Manual (80 pages)
Intelligent Control Panel, SLC
Brand:
Honeywell
| Category:
Control Panel
| Size: 3.06 MB
Table of Contents
Table of Contents
5
Section 1: Introduction
8
Scope
8
1: Reference Documentation
8
Overview
10
Polling Protocols
10
1: Available Protocols
10
2: Protocol Use
10
Devices
10
1: Isolator Modules
10
2: Monitor Modules
10
3: Control Modules
11
4: Relay Modules
11
5: Multiple Input/Output Modules
11
6: Intelligent Detectors
11
Manual Pull Station
12
8: Wireless Gateway
12
9: 300 Series Addressable Devices
12
10: 900 Series Addressable Devices
12
SLC Capacity
12
SLC Performance
12
Surge Suppression
13
LED Operation
13
Section 2: Wiring Requirements
14
Wire Sizing
14
1: CLIP (Classic Loop Interface Protocol) Mode
14
2: Litespeed Mode
14
Measuring Resistance & Length
14
1: Two-Wire SLC - Class B
14
2: Four-Wire SLC Class a and Class X
15
Shield Wire Termination
16
Control Panel Terminal Blocks
17
1: Ms-9200
17
2: Ms-9600, Ms-9600Ls, & Ms-9600Udls
17
3: MS-9200UDLS (Software Version 3.0)
18
4: MS-9200UD & MS-9200UDLS (Versions 1 and 2)
18
5: Ms-9050Ud
18
6: Es-50X
19
7: Es-200X
19
Section 3: SLC Circuits Without Isolators
20
Overview
20
NFPA Class B SLC
20
NFPA Class a SLC
21
Section 4: SLC Circuits with Isolators
22
Fault Isolator Devices
22
1: Isolating an SLC Branch
22
2: Wiring an Isolator Module
22
NFPA Class B SLC Using Isolator Modules
24
NFPA Class a SLC Using Isolator Modules
26
NFPA Class X SLC Using Isolator Modules
27
Section 5: Monitor Modules
28
Descriptions
28
1: Addressable Monitor Modules
28
2: Zone Interface Modules
30
3: Dual Monitor Module
32
4: Mini Monitor Module
32
Installation
32
1: Setting an SLC Address for a Single Point Module
33
2: Setting an SLC Address for a Multi-Point Module
33
MMF-300 Wiring Diagrams
34
1: Wiring a NFPA Class B IDC with an MMF-300
34
2: Wiring a NFPA Class a IDC with an MMF-300
35
3: MMF-300 Wiring for Emergency Alarm System Applications
36
MMF-300-10 Wiring Diagrams
37
1: Wiring a NFPA Class B IDC with an MMF-300-10
37
2: Wiring a NFPA Class a IDC with an MMF-300-10
38
MDF-300 Wiring Diagrams
39
1: Wiring a NFPA Class B IDC with an MDF-300
39
MMF-302 Wiring Diagrams
40
1: Wiring a NFPA Class B IDC with an MMF-302
40
2: Wiring a NFPA Class a IDC with an MMF-302
41
MMF-302-6 Wiring Diagrams
42
1: Wiring a NFPA Class B IDC with an MMF-302-6
42
2: Wiring a NFPA Class a IDC with an MMF-302-6
43
Section 6: Control Modules
44
Description
44
CMF-300 Installation
44
1: Setting an SLC Address for a CMF-300 Module
44
2: Wiring a Notification Appliance Circuit (NAC) with a CMF-300
44
Wiring a CMF-300 Module
44
1: Wiring a Class B NAC (Two-Wire) with Addressable Control Modules
44
2: Wiring a Class a NAC (Four-Wire) with Addressable Control Modules
45
CMF-300-6 Installation
46
1: Cabinet Installation
46
2: Setting an SLC Address for an CMF-300-6 Module
46
3: Setting Nacs as Class B or Class a
46
4: Disabling Unused Module Addresses
46
5: Short Circuit Protection
46
6: Features Not Supported
46
7: Circuit Board Information
47
Wiring a CMF-300-6 Module
48
1: Wiring a Class B NAC (Two-Wire)
48
2: Wiring a Class a NAC (Four-Wire)
49
Section 7: Relay Modules
50
Description
50
CRF-300 Installation & Wiring
50
1: Setting an SLC Address for a CRF-300 Module
50
2: Wiring a CRF-300 Module (Form-C Relay)
50
CRF-300-6 Circuit Board Information
51
CRF-300-6 Installation & Wiring
52
1: Cabinet Installation
52
2: Setting an SLC Address for a CRF-300-6 Module
52
3: Disabling Unused Module Addresses
52
4: Wiring a CRF-300-6 Module (Form-C Relay)
52
Section 8: Multiple Input/Output Modules
53
Description
53
CDRM-300 Installation & Wiring
53
1: Setting an SLC Address for a CDRM-300 Module
53
2: Wiring a CDRM-300 Module (Form-C Relay)
53
Section 9: Intelligent Detector Bases and Wireless Gateway
54
Description
54
Setting the Detector Address
54
Wiring a Detector Base
55
Wiring an Isolator Base
56
Wiring a Relay Base
56
Wiring a Sounder Base
57
Wiring the W-GATE
57
1: SLC Connections
58
2: W-GATE Powered by the SLC
58
3: W-GATE Powered by a Regulated, External +24VDC Power Source
59
Section 10: Addressable Beam Detectors
60
Description
60
Installation and Wiring
60
1: Setting an SLC Address for a Beam Detector
60
2: Wiring a Beam Detector
60
Section 11: Addressable Manual Pull Station
62
Description
62
Installation
62
1: Setting an SLC Address
62
2: Wiring a Manual Pull Station
62
Appendix A: Power Considerations
63
A.1: Supplying Power to 24 VDC Detectors and Nacs
63
A.1.1: Resistance and Size
63
A.2: Supervising 24 VDC Power
64
Appendix B: Surge Suppression
65
B.1: Introduction
65
B.2: Installation
65
B.2.1: Wiring Diagram for MS-9200
66
B.2.2: Wiring Diagram for MS-9600, MS-9600LS, MS-9600UDLS, MS-9200UD, MS-9200UDLS, and MS-9050UD
67
B.2.3: Wiring Diagram for ES-50X and ES-200X
68
Appendix C: Terminal Conversion Charts for New & Legacy Devices
69
C.1: Crf-300
69
C.2: CMF-300 and MMF-302
69
C.3: Mmf-300
70
C.4: Mdf-300
71
Appendix D: Intelligent Detector Base Layouts for Legacy Devices
72
D.1: B350LP or B501 Detector Base
72
D.2: B224BI Isolator Base
73
D.3: B224RB Relay Base
73
D.4: B501BH(-2) and B501BHT(-2) Sounder Bases
74
Appendix E: Canadian Versions of SLC Devices
75
Index
77
Advertisement
Honeywell Fire-Lite Alarms ES-50X Manual (4 pages)
Intelligent Addressable Fire Alarm Control Panels
Brand:
Honeywell
| Category:
Control Panel
| Size: 0.27 MB
Advertisement
Related Products
Honeywell ESSER IQ8Control M
Honeywell Fire-Lite Alarms ES-50XC
Honeywell Fire-Lite Alarms ES-200X
Honeywell Fire-Lite Alarms ES-200XC
Honeywell Fire-Lite Alarms ES-1000X
Honeywell Fire-Lite Alarms ES-1000XC
Honeywell Fire-Lite Alarms ES-1000XI
Honeywell FIRE-LITE ALARMS ES-50XI
Honeywell Fire-Lite Alarms ES-200XI
Honeywell TrolaTemp MABS EZ-4
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL