Sign In
Upload
Manuals
Brands
GE Manuals
Medical Equipment
LOGIQ V5
User Manuals: GE LOGIQ V5 Urology Ultrasound System
Manuals and User Guides for GE LOGIQ V5 Urology Ultrasound System. We have
2
GE LOGIQ V5 Urology Ultrasound System manuals available for free PDF download: Basic Service Manual, Service Manual
GE LOGIQ V5 Basic Service Manual (305 pages)
Brand:
GE
| Category:
Medical Equipment
| Size: 38.27 MB
Table of Contents
Certified Electrical Contractor Statement - for USA Only
14
Damage in Transportation
14
Omission and Errors
15
Service Safety Considerations
16
Copyrights
17
Legal Notes
17
Proprietary to GE
17
Trademarks
17
Table of Contents
19
Chapter 1 - Introduction
25
Overview
26
Contents in this Chapter
26
Manual Overview
27
Contents in this Manual
27
Overview
27
Typical Users of the Proprietary Service Manual
28
Purpose of Operator Manual(S)
28
LOGIQ V3/V5/V5 Expert Models Covered by this Manual
29
Important Conventions
30
Conventions Used in Book
30
Standard Hazard Icons
32
Product Icons
34
Labels Locations
35
Rating Plate Location
35
Safety Considerations
40
Contents in this Section
40
Introduction
40
Human Safety
40
Mechanical Safety
43
Electrical Safety
46
Dangerous Procedure Warnings
48
Lockout/Tagout (LOTO) Requirements
49
Returning Probes and Repair Parts
50
EMC, EMI and ESD
51
Electromagnetic Compatibility (EMC)
51
CE Compliance
51
Electrostatic Discharge (ESD) Prevention
52
Customer Assistance
53
Contact Information
53
Phone Numbers for Customer Assistance
54
System Manufacturer
54
Authorized Representative
55
Factory Site
55
Chapter 2 - Site Preparations
57
Overview
58
Contents in this Chapter
58
General Ultrasound System Requirements
59
Contents in this Section
59
Ultrasound System Environmental Requirements
59
Electrical Requirements
62
EMI Limitations
65
Probes Environmental Requirements
67
Time and Manpower Requirements
67
Facility Needs
68
Contents in this Section
68
Purchaser Responsibilities
69
Required Facility Needs
70
Desirable Features
71
Minimal Floor Plan Suggestion
72
Recommended Floor Plan Suggestion
73
Networking Setup Requirements
74
Chapter 3 - System Setup
77
Overview
78
Contents in this Chapter
78
Setup Reminders
79
Average Setup Time
79
Setup Warnings
79
Receiving and Unpacking the Equipment
82
Purpose of this Section
82
Contents in this Section
82
Warnings for Receiving and Unpacking
82
LOGIQ V3/V5/V5 Expert Transportation Box Label
83
Unpacking the LOGIQ V3/V5/V5 Expert
84
Packing the Equipment
88
Preparing for Setup
89
Verify Customer Order
89
Physical Inspection
89
EMI Protection
89
Completing the Setup
90
Purpose of this Section
90
Contents in this Section
90
System Specifications
90
Completing the Setup
91
Electrical Specifications
92
Connecting Cables
93
Peripherals/Accessories Connector Panel
94
Connections on the I/O Rear Panel
96
Connecting Probes
96
Powering the System
96
System Configuration
97
Purpose of this Section
97
LOGIQ V3/V5/V5 Expert Configuration
97
Peripherals Installation
102
Overview
102
Furnished Materials
103
Peripherals Installation Instructions
105
Option Setup
120
Software Option Installation Procedure
120
Paperwork after Setup
123
Contents in this Section
123
User's Manual(S)
123
Product Locator Installation Card
123
Chapter 4 - General Procedures and Functional Checks
125
Overview
126
Purpose of this Chapter
126
Contents in this Chapter
126
Special Equipment Required
126
General Procedures
127
Overview
128
Power On/Boot up
129
Power off
132
Check System Date and Time
134
Manufacturer
135
Removable Media
135
Functional Checks
145
Overview
145
Contents in this Section
145
Preparation
145
Basic Controls
146
Control Panel
146
LOGIQ V5/LOGIQ V3 Softmenu Key Tour
147
Control Panel
148
Performance Tests
149
Mode (B Mode) Checks
150
Mode Screen Example
150
Preparations
150
Adjust the 2D Mode Controls
150
Image Quality Check (IQC) Preset for Service
151
M Mode Checks
153
M-Mode Screen Example
153
Preparations
153
Adjust the M Mode Controls
153
Color Mode Checks
154
Select Color 2D Mode
154
Adjust the Color Mode Controls
155
Select Color M Mode
156
PW Doppler Mode Checks
158
Adjust the PW Doppler Mode Controls
159
Tissue Velocity Imaging (TVI) Checks
160
Adjust the TVI Controls
161
Basic Measurements
162
Probe/Connectors Check
163
ECG Check
165
Cineloop Check
166
Preparation
166
Adjust the Cineloop Controls
166
Back End Processor Checks
166
Operator Panel Test
167
Peripheral Checks
167
Turn off Power to LOGIQ V3/V5/V5 Expert
167
Mechanical Functions Checks
167
Application Turnover Check List
169
Software Configuration Checks
169
Site Log
170
My Trainer
171
Overview
171
Chapter 5 - Components and Functions (Theory)
175
Overview
176
Contents in this Chapter
176
Block Diagram and Theory
177
Block Diagram
177
Introduction
178
Chapter 6 - Service Adjustments
181
Overview
182
Contents in this Chapter
182
LCD Monitor Adjustments
183
Purpose of this Section
183
Chapter 7 - Diagnostics/Troubleshooting
189
Overview
190
Contents in this Chapter
190
Gathering Trouble Data
191
Overview
191
Collect Vital System Information
191
Collect a Trouble Image with Logs
192
Screen Capture
193
Capturing a Screen
194
Capturing a Screen with Service Dongle
197
Global Service User Interface (GSUI)
200
Enter Global Service User Interface
200
Control Frame
203
Common Diagnostics
204
Network and Insite II Configuration
217
Network Configuration
217
Chapter 8 - Replacement Procedures
223
Overview
224
Warnings and Important Information
225
Warnings
225
Returning/Shipping Probes and Repair Parts
226
Loading the Software
227
Purpose of this Section
227
Customer Provided Prerequisite
227
Data Management - Moving All Images
227
Backing up the Patient Archive and System Configurations
228
Restoring up the Patient Archive and System Configurations
228
Recording Important Settings and Parameters
229
Loading the System Software
230
Rewrite the Serial Number
244
Chapter 9 - Renewal Parts
253
Overview
254
Contents in this Chapter
254
List of Abbreviations
255
Renewal Parts Lists
256
Operator Console Assy
256
Probe
257
Peripheral
257
Power Cord
260
Manuals
261
Chapter 10 - Care and Maintenance
265
Overview
266
Contents in this Chapter
266
Warnings
267
Why Do Maintenance
268
Periodic Maintenance Inspections
268
Keeping Records
268
Quality Assurance
269
Maintenance Task Schedule
270
How Often Should Maintenance Tasks be Performed
270
Tools Required
272
Standard GE Tool Kit
272
Tool Kit
274
Special Tools, Supplies and Equipment Used for Maintenance
275
System Maintenance
276
Preliminary Checks
276
Functional Checks
277
Physical Inspection
279
Optional Diagnostic Checks
280
Probe Maintenance
281
Electrical Safety Tests
283
Safety Test Overview
283
Leakage Current Limits
285
Outlet Test - Wiring Arrangement
287
Grounding Continuity
288
Chassis Leakage Current Test
289
Probe Leakage Current Test
291
When There's too Much Leakage Current
294
AC/DC Fails
294
Chassis Fails
294
Probe Fails
295
Peripheral Fails
295
Still Fails
295
New Unit
295
ECG Fails
295
Inspection Paperwork
296
Ultrasound Inspection Forms
296
Electrical Safety Tests Log
298
Advertisement
GE LOGIQ V5 Service Manual (170 pages)
Brand:
GE
| Category:
Medical Equipment
| Size: 2.72 MB
Table of Contents
Table of Contents
15
Part Number
12
Diagnostics/Troubleshooting
21
CHAPTER 1 Introduction
25
Overview
25
Purpose of Chapter 1
25
Purpose of Service Manual
25
LOGIQ V5/LOGIQ V3 Models Covered by this Manual
26
Purpose of Operator Manual(S)
26
Typical Users of the Basic Service Manual
26
Important Conventions
29
Conventions Used in Book
29
Standard Hazard Icons
30
Product Icons
31
Safety Considerations
34
Human Safety
34
Introduction
34
Mechanical Safety
34
Electrical Safety
35
Label Locations
35
Dangerous Procedure Warnings
36
Returning/Shipping Probes and Repair Parts
37
Lockout/Tagout (LOTO) Requirements
38
EMC, EMI, and ESD
39
CE Compliance
39
Electromagnetic Compatibility (EMC)
39
Electrostatic Discharge (ESD) Prevention
39
Customer Assistance
40
Contact Information
40
Factory Site
41
System Manufacturer
41
CHAPTER 2 Site Preparations
43
Overview
43
Purpose of Chapter 2
43
General Console Requirements
44
Console Environmental Requirements
44
Electrical Requirements
44
EMI Limitations
46
Scan Probe Environmental Requirements
47
Facility Needs
48
Purchaser Responsibilities
48
Required Features
49
Minimal Floor Plan Suggestion
50
Recommended Floor Plan Suggestion
51
Suggested Floor Plan, Ultrasound System, and Echopac PC in same Room
52
Networking Pre-Installation Requirements
53
CHAPTER 3 System Setup
55
Overview
55
Purpose of Chapter 3
55
Setup Reminders
56
Average Installation Time
56
Installation Warnings
57
Safety Reminders
58
Receiving and Unpacking the Equipment
59
Moving into Position
63
Product Locator Installation Card
63
Preparing for Installation
64
EMI Protection
64
Physical Inspection
64
Verify Customer Order
64
Completing the Installation
65
Power on / Boot up
65
Power Off/ Shutdown
66
Transducer Connection
66
System Configuration
67
Electrical Specifications
67
On-Board Optional Peripherals
67
System Specifications
67
Connecting Cables
68
Peripherals/Accessories Connector Panel
68
Available Probes
78
Software/Option Configuration
78
Connectivity Installation Worksheet
79
Loading Base Image Software
80
Software Version Check out
81
Functional Check-Out
81
Paperwork
82
Product Locator Installation
82
User Manual(S)
82
CHAPTER 10 Care & Maintenance
83
Overview
83
CHAPTER 4 Functional Checks
84
General Procedure
84
Power Off/ Shutdown
85
Archiving and Loading Presets
87
Adjusting the Display Monitor
88
System Features
89
B Mode Checks
92
M Mode Controls
96
Doppler Mode Checks
98
Color Flow Mode Checks
101
Basic Measurements
104
Probe/Connectors Usage
105
Using Cine
106
Backup and Restore Database, Preset Configurations and Images
107
Software Configuration Checks
114
Overview
117
CHAPTER 5 Components and Functions (Theory)
118
Block Diagram
118
Common Service Platform
119
Overview
121
Monitor Adjustments
122
Overview
123
CHAPTER 7 Diagnostics/Troubleshooting
124
Gathering Trouble Data
124
Collect a Trouble Image with Logs
125
Screen Captures
126
Capturing a Screen
127
Reset the Store Key to Customer's Functionality
128
Common Diagnostics
129
Network Configuration
130
Overview
133
CHAPTER 8 Replacement Procedures
134
Disassembly/Re-Assembly
134
Footrest
135
Loading Base Image Software
136
Overview
139
CHAPTER 9 Renewal Parts
140
Renewal Parts Lists
140
Operator Console Assy
141
CRU Parts List
142
Manuals
143
Probes
147
Overview
149
Why Do Maintenance
150
Tools Required
152
Special Tools, Supplies and Equipment
154
Input Power
155
Outlet Test -Wiring Arrangement - USA & Canada
156
Grounding Continuity
157
Chassis Leakage Current Test
158
Isolated Patient Lead (Source) Leakage–Lead to Lead
159
Probe Leakage Current Test
161
When There's too Much Leakage Current
163
Advertisement
Related Products
GE LOGIQ V1
GE Vivid P3
GE Vivid q
GE Voluson Expert 18
GE Voluson Expert 20
GE Voluson Expert 22
GE Voluson Expert 18 Series
GE Voluson Expert 20 Series
GE VividE95
GE Vscan Air
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL