Table 2. Power-supply LEDs
Power-supply LEDs
AC
DC
Off
Off
Off
Off
Off
On
Off
On
On
Off
On
Off or
Flashing
On
On
On
On

Server power features

20
System x3650 M2 Type 7947: Installation and User's Guide
Downloaded from
www.Manualslib.com
Error
Description
Off
No ac power to
the server or a
problem with the
ac power source
On
No ac power to
the server or a
problem with the
ac power source
and the power
supply had
detected an
internal problem
Off
Faulty power
supply
On
Faulty power
supply
Off
Power supply not
fully seated,
faulty system
board, or faulty
power supply
On
Faulty power
supply
Off
Normal operation
On
Power supply is
faulty but still
operational
When the server is connected to a power source but is not turned on, the operating
system does not run, and all core logic except for the integrated management
module (IMM) is shut down; however, the server can respond to requests from the
IMM, such as a remote request to turn on the server. The power-on LED flashes to
indicate that the server is connected to power but is not turned on.
Turning on the server
Approximately 3 minutes after the server is connected to power, the power-control
button becomes active, and one or more fans might start running to provide cooling
while the server is connected to power. You can turn on the server and start the
operating system by pressing the power-control button.
The server can also be turned on in any of the following ways:
manuals search engine
Action
1. Check the ac power to the server.
2. Make sure that the power cord is
connected to a functioning power
source.
3. Turn the server off and then turn the
server back on.
4. If the problem remains, replace the
power supply.
1. Replace the power supply.
2. Make sure that the power cord is
connected to a functioning power
source.
Replace the power supply.
Replace the power supply.
1. Reseat the power supply.
2. If the 240V failure LED on the system
board is lit, have the system board
replaced (trained service technician
only).
3. If the 240V failure LED on the system
board is not lit, replace the power
supply.
Replace the power supply.
Replace the power supply.
Notes
This is a normal
condition when no
ac power is present.
This happens only
when a second
power supply is
providing power to
the server.
Typically indicates
that a power supply
is not fully seated.