The Eagle Model 1241 requires the following hardware: 1. A communicator/control panel which has a Two Way trip connection or a control panel with an Eagle Model 1405 or Model 1406 Activation Module (when used in the line hold mode.) 2.
ON = 6 rings before answering. OFF = 10 rings before answering. If SW1 is in the NORMAL MODE (OFF) and ring detect is OFF (SW4 is OFF) then the operation of the Model 1241 is independent of SW2's setting.
Page 5
Eagle Model 1405 or 1406 activation module is required. When SW5 is in the OFF position a trigger input will activate a five (5) minute window. The 1241 will answer the phone line as soon as it sees one ring within this window. The system will ignore any invalid phone calls (see section 4.2).
TABLE 1: SUMMARY OF SWITCH SETTINGS. SWITCH FUNCTION OPERATION FACTORY TEST NORMAL 2 (SW1 ON) TIME OUT FAST TIME OUT NORMAL TIME OUT 2 (SW1 OFF) # RINGS 6 RING ANSWER 10 RING ANSWER ACTIVATE IN VOX (2-WAY) LISTEN ONLY RING DETECT FULL TIME ON FULL TIME OFF...
Page 7
14VDC. Consult factory for assistance with your equipment. ANS HGUP: This input is only used when it is desired to operate the 1241 as a Hands Free "Speaker Phone" in addition to its normal function. Connect GND and ANS HGUP to a Normally Open switch (if desired). Also used when using Model 1405 Activation Module.
3.5.3 QUANTITY OF MICROPHONES AND SPEAKERS. Microphones. The Model 1241 is designed to handle up to four microphones (one per input). If additional microphones are required they may be installed in a parallel configuration. If this is utilized, it is recommended to configure ALL used inputs the same (all single or all double).
FIVE MINUTE WINDOW. The Model 1241 has a call back mode which activates upon a trip. The window is initiated from the trip input. This sets up the system to answer an alarm which has just been reported by the digital communicator (SW5 is OFF). The operator will have 5 minutes in which to call back the system and have it answer within one ring.
Repeat if necessary. The Model 1241 provides five (5) minutes of Two Way. During Two Way, the module will generate a "beep" once every minute. Upon the fourth and final minute of Two Way the module will generate a two tone "beep bop" warning the central station that there is only one more minute of Two Way before the module automatically disconnects.
Page 11
To extend the Two Way shut down time (reset to 5 minutes), press and release at any time during the Two Way (before the module disconnects). Additionally, anytime a command is sent to the Model 1241 (a ) the module will automatically reset the five minute timer. The only time the...
P1 - DPDT relay connection. If the system to which the Model 1241 is connected is using an internal sounder (siren, bell or buzzer), it should be interrupted during Two Way. This will allow the central station maximum listen-in ability without interference. These connections may be made at either of two places.
Page 13
DIAGRAM 4: SIREN DRIVER CONNECTIONS. Orange Blue YELP-1&2 SWEP-2&3 EAGLE SECURITY GND (-) FROM CONTROL PANEL Red/Wht +12 VDC FROM CONTROL PANEL Relay 2 (COM) Relay 2 (N.C.) Relay 2 (N.O.)
Page 14
The Model 1402 provides three additional speaker outputs. If it is desired to connect more than four speakers to the Model 1241 or additional power is desired on each of the first four speakers, then the Model 1402 must be used.
Features and specifications subject to change without notification. ♦ Use of this equipment may be in violation of local laws. Please verify and obey all local laws. Eagle Security Products, Inc. does not assume any liability for the illegal use of this equipment.
LIMITED WARRANTY Eagle Security Products, Inc. Warrants that the products of its manufacture shall be free from defects in materials or workmanship to one year from the date of invoice if such goods have been properly installed, are subject to normal proper use, and have not been modified in any manner whatsoever. Upon return of the defective product to the nearest Eagle Security Products dealer, Eagle Security Products will, at its sole discretion, either repair or replace, at no cost to the customer, such goods as may be of defective material or workmanship.