(1xxx) System Power Control Network (SPCN) Reference Codes
The system power control network (SPCN) detected a failure.
1. Look at the four rightmost characters of the SRC (data display for function 11-3).
These four characters are the unit reference code.
2. Find the unit reference code in the following table.
Reference
Description/Action
Code
(Perform all actions before exchanging Failing
Items)
00A0
SPCN BATs in process.
No action required. This reference code is logged
for information only. If this reference code is
present for more than 1 minute, go to "MAP 1540:
Minimum Configuration" on page 117.
00A1
Regulator 1 has been turned off by system.
No action required. This reference code is logged
for information only.
00A2
Regulator 2 has been turned off by system.
No action required. This reference code is logged
for information only.
00A3
Regulator 3 has been turned off by system.
No action required. This reference code is logged
for information only.
00A4
Regulator 4 has been turned off by system.
No action required. This reference code is logged
for information only.
00A5
Regulator 5 has been turned off by system.
No action required. This reference code is logged
for information only.
00A6
Regulator 6 has been turned off by system.
No action required. This reference code is logged
for information only.
00AA
Download in process.
No action required. This reference code is logged
for information only.
Failing Item
Chapter 5. Error Code to FRU Index
1xxx
189