APPLICATION
The TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat provides electronic control of 24 Vac heating
and cooling systems.
See Table 1 for a description.
Feature
Powering Methods
System Types
Changeover
System Setting
Fan Setting
Fan Speeds
Remote Setback
Fan Ramping
Algorithm
MERCURY NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.
Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of an old control.
Table 1. TB7100A Thermostat Description.
• Battery only
• 24 Vac only
• 24 Vac with battery backup
• Conventional (1 Heat, 1 Cool stages)
• Heat Pump (up to 2 Heat,1 Cool stages)
• 2 Pipe Fan Coil
• 2 Pipe Fan Coil with Auxiliary Heat
• 4 Pipe Fan Coil
• PTAC (up to 2 Heat, 1 Cool)
Manual or automatic changeover selectable
Heat-Off-Cool-Auto
Auto, On
Low, Medium, High
Remote Setback Input for occupancy sensor or DDC setback
VersaSpeed™ Fan Ramping Algorithm for automatic fan speed selection (fan coil and PTAC
applications)
INSTALLATION INSTRUCTIONS
Description
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a
hazardous condition.
2. Check ratings given in instructions and on the
product to ensure the product is suitable for your
application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
62-0273-05

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell TB7100A1000 MultiPRO

  • Page 1 TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat APPLICATION The TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat provides electronic control of 24 Vac heating and cooling systems. See Table 1 for a description. Feature Powering Methods • Battery only • 24 Vac only •...
  • Page 2: Wiring

    TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. Select Thermostat Location Select a location for the thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at average temperature.
  • Page 3 If thermostat is configured for a heat pump in the Installer Setup, configure changeover valve for cool (O-factory setting) or heat (B). Sensor wires must have a cable separate from the thermostat control cable. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT WALLPLATE M22266 Table 2. Terminal Designation Descriptions. Description...
  • Page 4 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Conventional System Wiring (HOT) 24 VAC COMPRESSOR CONTACTOR FAN RELAY HEAT RELAY POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL.
  • Page 5 OPTIONAL INDOOR REMOTE SENSOR OR REMOTE SETBACK. WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE. Fig. 12. Typical hookup of single-stage heat pump with auxiliary heat (2H/1C). TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Fan Coil System Wiring (HOT) INDOOR TEMPERATURE SENSOR/REMOTE...
  • Page 6 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT PTAC System Wiring (HOT) 24 VAC CHANGEOVER VALVE COMPRESSOR CONTACTOR LOW FAN RELAY POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS OPTIONAL.
  • Page 7: Power The Thermostat

    1. Install two AA alkaline batteries on the back of the thermostat as marked. See Fig. 22. BATTERIES (2) BACK OF THERMOSTAT Fig. 22. Installing batteries. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT 2. Locate and remove the tab labeled Remove. See IMPORTANT REMOVE M27432 Fig.
  • Page 8: Advanced Settings

    TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT SETTING CALENDAR AND TIME This thermostat is designed to, under normal use, automatically keep current time and day in memory for up to ten years once the calendar is set. There are two ways...
  • Page 9: Configure Installer Setup

    (CPH) for first stage cooling/compressor 0240 CPH for first stage heat 0270 CPH for Em Heat 0280 Continuous Backlight TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT IMPORTANT Table 4. Installer Setup Menu. All Settings 20—21 00-99 1-12 1-31 (Month Dependent) 0—Non-Programmable 4—Programmable 1—1H/1C Conv...
  • Page 10 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Installer Setup Installer Setup Default Number Name Setting 0300 Changeover 0310 Deadband 3°F (2°C) 0320 Temperature Indication Scale 0330 Daylight Saving 0340 Remote Temp Sensor/Remote Setback/ Changeover Input 0340 Remote Temp (Non- Sensor/Remote program...
  • Page 11 Ramp Rate 0690 Temperature Control Cool 0695 Recovery Cool Ramp Rate TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 4. Installer Setup Menu. (Continued) All Settings 0—Inactive 1—Reset back to Auto after 2 hours 2—Reset back to Auto after 4 hours 0–12 hours...
  • Page 12 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Installer Setup Installer Setup Default Number Name Setting 0700 Temperature Display Offset 0710 Restore Factory Defaults 0720 Screen Display INSTALLER TESTS Test 1 Installer Test Cool Test 2 Installer Test Test 3 Installer Test...
  • Page 13 The thermostat will have a priority when choosing a system mode (heat or cool). When ISU 340 TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT has a 2 pipe changeover sensor enabled, the thermostat screen system mode will lock on heat or cool (whatever the changeover sensor is communicating to the thermostat).
  • Page 14: System Settings

    TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT System Settings Heat—Thermostat controls the heating system. Off—Both heating and cooling systems are off. Fan is turned off. Cool—Thermostat controls the cooling system. Auto—Thermostat automatically changes between heat and cool operation, depending on indoor temperature.
  • Page 15 Wait is in the display. Compressor minimum off timer is active. TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 6. Troubleshooting. (Continued) Possible Cause Set Changeover Valve (Installer Setup Number 0190) to match the changeover required by the installed heat pump.
  • Page 16: Specifications

    TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT SPECIFICATIONS Electrical Ratings: Voltage Terminal (50/60 Hz) W (Heating) 20 - 30 Vac Y (Cooling) 20 - 30 Vac G (Fan) 20 - 30 Vac Temperature Setting Range: Heating: 40°F to 90°F (4.5°C to 32°C).