Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
LA240HSV2
Art Cool™ Single Zone Inverter
Outdoor Unit (ODU)‐LAU240HSV2
Performance:
Cooling:
Capacity (Btu/h)
SEER
EER
SEER ‐ Seasonal Energy Efficiency Ratio EER ‐ Energy Efficiency Ratio
Heating:
Capacity (Btu/h)
HSPF
HSPF ‐ Heating Seasonal Performance Factor
Cooling Nominal Test Conditions:
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Electrical:
Outdoor Unit:
Power Supply (V¹/Hz/Ø)
MOP (A)
MCA (A)
Cooling Rated Amps (A)
Heating Rated Amps (A)
Compressor (A)
Fan Motor (A)
MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity
Indoor Unit:
Power Supply (V¹/Hz/Ø)
Cooling Power Input (kW)
Heating Power Input (kW)
Piping:
Liquid Line (in, OD)
Vapor Line (in, OD)
Additional Refrigerant (oz/ft)
Max Pipe Length (ft)²
Piping Length (no add'l refrigerant, ft)
Max Elevation (ft)
Features:
•Chaos wind
•4‐Way auto swing
•Condensate Sensor
•24‐Hour on/off mer
Connection
•Auto restart
•Energy saving
•Auto changeover
•Inverter (variable speed
•Built‐in low ambient
compressor)
standard, down to 14°F
(cooling mode)
Optional Accessories (sold separately):
7‐Day Programmable Controller (Black) ‐ PQRCVSL0
7‐Day Programmable Controller (White) ‐ PQRCVSL0QW
Dry Contact for third party thermostat ‐ PQDSBNGCM1
PI485 ‐ PMNFP14A0
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com
For:
GC:
Mech:
(Project Manager)
Indoor Unit (IDU)‐LAN240HSV2
22,000
20.0
10.8
27,600
10.0
Heating Nominal Test Conditions:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
208‐230/60/1
17.0
17.0
14.6
0.75
208‐230/60/1
2.04
1.67
3/8
5/8
0.38
•Jet cool/Jet heat
•Plasma air purifying
system
•Self‐cleaning indoor coil
•Sleep mode
•Ultra quiet opera on
File
Resubmit
Approval
Other
Operating Range:
Outdoor Unit:
Cooling (°F DB)
Heating (°F DB)
Indoor Unit:
Cooling (°F DB)
Heating (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control
Refrigerant Charge (lbs)
ODU Sound Pressure Max (±3 dB(A))³
IDU Sound Pressure (H/M/L) (±3 dB(A))³
ODU Net Unit Weight (lbs)
30
ODU Shipping Weight (lbs)
19
IDU Net Unit Weight
IDU Shipping Weight (lbs)
Heat Exchanger Coating
Communication Cable (No x AWG)⁴
AWG ‐ American Wire Gage
Fan:
ODU Type
IDU Type
Fan Speeds (Fan/Cooling/Heating)
Quantity (ODU + IDU)
Motor/Drive
ODU Max Air Flow Rate (CFM)
IDU Max Air Flow H/M/L (CFM)
Dehumidification (pts/hr)
Notes:
98
1.Acceptable opera ng voltage: 187V ‐ 253V.
25
2.Piping lengths are equivalent.
3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
49
4.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must
comply with applicable local and national code.
5.See Engineering Manual for sensible and latent capaci es.
6.Power wiring cable size must comply with the applicable local and na onal code.
7.The indoor unit comes with a dry helium charge.
8.This data is rated 0 above sea level, with 24.6 of refrigerant line and a 0 level difference
between outdoor and indoor units.
9.Must follow installa on instruc ons in the applicable LG installa on manual.
Standard Features:
•Limited Five Year Compressor Warranty
•Limited Three Year Func onal Parts Warranty
Tag #:
Brushless Digitally Controlled/Direct
DFS‐SB‐AA‐030‐US 012H29
14‐118
5‐75
64‐90
61‐86
R410A
EEV
3.97
53
45/40/35
133
142
38
42
GoldFin™
4 x 18
Propeller
Cross Flow
5/6/6
1 + 1
2,119
600/510/420
5.5
Page 1 of 3