hit counter script
Whirlpool WED94HEAC Installation Instructions Manual
Whirlpool WED94HEAC Installation Instructions Manual

Whirlpool WED94HEAC Installation Instructions Manual

Installation guide
Hide thumbs Also See for WED94HEAC:

Advertisement

ELECTRIC DRYER INSTALLATION INSTRUCTIONS
W10508904B
W10508905B - SP

Table of Contents

DRYER SAFETY ......................................................................... 2
INSTALLATION REQUIREMENTS ............................................. 3
Tools and Parts ...................................................................... 3
LOCATION REQUIREMENTS .................................................... 4
ELECTRICAL REQUIREMENTS ................................................ 5
INSTALL LEVELING LEGS ......................................................... 6
ELECTRICAL INSTALLATION ................................................... 7
Power Supply Cord Connection ........................................... 8
Direct Wire Connection ....................................................... 10
VENTING ................................................................................... 12
Venting Requirements ......................................................... 12
Plan Vent System ................................................................. 13
Install Vent System .............................................................. 14
CONNECT VENT ...................................................................... 16
LEVEL DRYER .......................................................................... 17
COMPLETE INSTALLATION CHECKLIST .............................. 17
DOOR REVERSAL (OPTIONAL) .............................................. 17
Para una version de estas instrucciones en español, visite www.Whirlpool.com
INSTALLATION NOTES
_________________________________
Date of purchase:
Date of installation:
________________________________________
Installer:
___________________________________
Model number:
___________________________________
Serial number:
_______________________________
1

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool WED94HEAC

  • Page 1: Table Of Contents

    CONNECT INLET HOSE (STEAM MODEL ONLY)....15 CONNECT VENT ..............16 LEVEL DRYER ................17 COMPLETE INSTALLATION CHECKLIST ......17 DOOR REVERSAL (OPTIONAL) ..........17 Para una version de estas instrucciones en español, visite www.Whirlpool.com INSTALLATION NOTES _________________________________ Date of purchase: _______________________________...
  • Page 2: Dryer Safety

    DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
  • Page 3: Installation Requirements

    INSTALLATION REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before starting installation. Parts supplied (all models): Tools needed: Flat-blade screwdriver #2 Phillips screwdriver Leveling legs (4) Parts supplied (steam models): Wire stripper (direct wire Tin snips (new vent installations) installations) “Y”...
  • Page 4: Location Requirements

    DRYER DIMENSIONS LOCATION REQUIREMENTS Front view: 27" Check code requirements. Some codes limit, or do not permit, (686 mm) installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. " (968 mm) "* (18 mm) * Approx.
  • Page 5: Electrical Requirements

    Installation spacing for recessed area ELECTRICAL REQUIREMENTS or closet installation All dimensions show recommended and minimum spacing It is your responsibility: allowed. To contact a qualified electrical installer. ■ Additional spacing should be considered for ease of ■ To be sure that the electrical connection is adequate and ■...
  • Page 6: Install Leveling Legs

    If your outlet looks like this: INSTALL LEVELING LEGS Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R.
  • Page 7: Electric Installation

    ELECTRIC INSTALLATION For power supply cord installations: For direct wire installations: Before you start: disconnect power. Remove terminal block cover Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R). Go to Power Supply Cord Connection. Power supply cord 3-wire receptacle (NEMA Type 10-30R).
  • Page 8: Power Supply Cord Connection

    Power Supply Cord Connection 4-Wire Power Supply Cord Connection IMPORTANT: A 4-wire connection is required for mobile homes Power supply cord strain relief: and where local codes do not permit the use of 3-wire connections. Attach power supply cord strain relief 4-wire receptacle (NEMA 4-prong plug type 14-30R)
  • Page 9 Connect ground wire Remove center screw Connect ground wire (F) (green or bare) of power supply cord Remove center terminal block screw (B). under green external ground conductor screw (A). Tighten screw. Connect neutral wire Connect remaining wires Connect neutral wire (white or center) (C) of power supply cord under center terminal block screw (B).
  • Page 10: Direct Wire Connection

    Direct Wire Connection 4-Wire Direct Wire Connection IMPORTANT: A 4-wire connection is required for mobile homes Direct wire strain relief and where local codes do not permit 3-wire connections. Attach direct wire strain relief Prepare your 4-wire cable for direct connection Direct wire cable must have 5 ft.
  • Page 11 Connect ground wire Remove center screw Connect ground wire (green or bare) (F) of direct wire cable Remove center terminal block screw (B). under green external ground conductor screw (A). Tighten screw. Connect neutral wire Connect remaining wires Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B), hook facing right.
  • Page 12: Venting

    Optional External Ground for 3-Wire Connect external ground wire Connection Power Supply Cord Shown) IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting. Prepare to connect neutral ground wire and neutral wire Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground.
  • Page 13: Plan Vent System

    Rigid metal vent: Clamps: Use clamps to seal all joints. ■ Recommended for best drying performance and to avoid ■ Exhaust vent must not be connected or secured with screws crushing and kinking. ■ or other fastening devices that extend into interior of duct Flexible metal vent: and catch lint.
  • Page 14: Install Vent System

    Determine vent path: Select route that will provide straightest and most direct ■ path outdoors. Plan installation to use fewest number of elbows and turns. ■ When using elbows or making turns, allow as much room ■ as possible. Bend vent gradually to avoid kinking. ■...
  • Page 15: Connect Inlet Hose (Steam Model Only)

    Attach short hose and Connect vent to exhaust hood “Y” connector Fig. B Fig. A If space permits, attach the female end of the “Y” connector to the cold water faucet. See figure A. Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4"...
  • Page 16: Connect Vent

    CONNECT VENT Attach long hose to dryer fill valve and tighten coupling Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood.
  • Page 17: Level Dryer

    LEVEL DRYER COMPLETE INSTALLATION CHECKLIST Level dryer Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped. Check that you have all of your tools. Place Dispose of/recycle all packaging materials. level here Be sure the water faucets are on.
  • Page 18: Door Reversal (Optional)

    DOOR REVERSAL (OPTIONAL) Move the door strike The following instructions are for models with a round and square-shaped doors. Tools needed: Min. 8" long TORX #2 Phillips screwdriver ® † T25 screwdriver Reverse door swing round-shaped door - single handle Remove door from dryer Using a TORX T25 screwdriver, remove the 2 screws securing the door strike to the door frame of the dryer.
  • Page 19 Remove outer window assembly Reverse outer window assembly from trim ring Handle Using a Phillips screwdriver, remove the 2 screws from the outer window retainer and rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with arrows in the figure A above.
  • Page 20 Rotate and reassemble outer window Remove hinge and latch assembly to trim ring Latch Bottom of door Notches Hinge Using a TORX T25 screwdriver, remove the 3 TORX screws ® securing the latch plate and latch backing plate and the 5 screws holding the hinge assembly in place.
  • Page 21 Reverse door swing round-shaped door - double handle Reinstall inner door assembly Remove door from dryer Bottom of door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from the dryer door before proceeding.
  • Page 22 Remove inner door from outer door Reinstall hinge and latch on opposite sides Using a TORX T25 screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX screws removed earlier and the hinge assembly with the 5 screws on the opposite Position the door with the inside of the door facing up.
  • Page 23: Reverse Door Swing Square-Shaped Door

    Reinstall door on dryer Move the door strike Using a TORX T25 screwdriver, remove the 2 screws securing Using a TORX T25 screwdriver, remove the 4 screws on the ® the door strike to the door frame of the dryer. Remove the dryer.
  • Page 24 Using a TORX T25 screwdriver, reinstall the latch plate and the door hinge to the dryer. hinge assembly on the opposite sides from which they were removed. W10508904B ©2012 Whirlpool Corporation. All rights reserved. 08/12 Used under license in Canada. Printed in U.S.A. W10508905B - SP ©2012 Whirlpool Corporation.

This manual is also suitable for:

Wed94heawWed96heacWed96heauWed96heawWed72hedw

Table of Contents