Technical Data
Voltage
Type
Battery type
Power output
No-load speed
Router carriage
Router carriage stroke
Collet Size
Cutter Diameter, max
Weight (without battery pack)
Noise and/or vibration values (triax vector sum) according to EN60745-2-17:
(emission sound pressure level)
L
PA
L
(sound power level)
WA
K (uncertainty for the given sound
level)
Vibration emission value a
=
h
Uncertainty K =
The vibration and/or noise emission level given in this
information sheet has been measured in accordance with
a standardised test given in EN60745 and may be used to
compare one tool with another. It may be used for a preliminary
assessment of exposure.
WARNING: The declared vibration and/or noise emission
level represents the main applications of the tool. However
if the tool is used for different applications, with different
accessories or poorly maintained, the vibration and/or
noise emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration and/
or noise should also take into account the times when the
tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure
level over the total working period.
Identify additional safety measures to protect the
operator from the effects of vibration and/or noise such
as: maintain the tool and the accessories, keep the
hands warm (relevant for vibration), organisation of
work patterns.
EC-Declaration of Conformity
Machinery Directive
WALT one of the
E
Plunge Router
DCW600
DCW604
DCW600, DCW604
V
18
18
WALT declares that these products described under
D
DC
E
1
1
Technical Data are in compliance with:
2006/42/EC, EN60745-1:2009 +A11:2010, EN60745-2-17:2010.
Li-Ion
Li-Ion
These products also comply with Directive 2014/30/EU and
W
930
930
2011/65/EU. For more information, please contact D
rpm
16000–
16000–
the following address or refer to the back of the manual.
25500
25500
The undersigned is responsible for compilation of the technical
1 column
2 columns
file and makes this declaration on behalf of D
mm
55
55
mm
8
8
30
30
kg
1.54
2.40
Markus Rompel
Vice-President Engineering, PTE-Europa
WALT, Richard-Klinger-Straße 11,
D
E
dB(A)
73
73
D-65510, Idstein, Germany
dB(A)
84
84
15.03.2019
dB(A)
3
3
m/s
4.7
4.7
2
Definitions: Safety Guidelines
m/s
2.7
2.7
2
The definitions below describe the level of severity for each
signal word. Please read the manual and pay attention to
these symbols.
WARNING: To reduce the risk of injury, read the
instruction manual.
DANGER: Indicates an imminently hazardous
situation which, if not avoided, will result in death or
serious injury.
WARNING: Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.
CAUTION: Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury.
NOTICE: Indicates a practice not related to
personal injury which, if not avoided, may result in
property damage.
Denotes risk of electric shock.
Denotes risk of fire.
ENGLISH
WALT at
E
WALT.
E
33