hit counter script
Download Print this page
DeWalt DCW600N-XJ Manual
DeWalt DCW600N-XJ Manual

DeWalt DCW600N-XJ Manual

Plunge router

Advertisement

Quick Links

PLUNGE ROUTER
DCW600, DCW604
Congratulations!
You have chosen a D
WALT tool. Years of experience, thorough
E
product development and innovation make D
most reliable partners for professional power tool users.
Technical Data
Voltage
Type
Battery type
Power output
No-load speed
Router carriage
Router carriage stroke
Collet Size
Cutter Diameter, max
Weight (without battery pack)
Noise and/or vibration values (triax vector sum) according to EN60745-2-17:
(emission sound pressure level)
L
PA
L
(sound power level)
WA
K (uncertainty for the given sound
level)
Vibration emission value a
=
h
Uncertainty K =
The vibration and/or noise emission level given in this
information sheet has been measured in accordance with
a standardised test given in EN60745 and may be used to
compare one tool with another. It may be used for a preliminary
assessment of exposure.
WARNING: The declared vibration and/or noise emission
level represents the main applications of the tool. However
if the tool is used for different applications, with different
accessories or poorly maintained, the vibration and/or
noise emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration and/
or noise should also take into account the times when the
tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure
level over the total working period.
Identify additional safety measures to protect the
operator from the effects of vibration and/or noise such
as: maintain the tool and the accessories, keep the
hands warm (relevant for vibration), organisation of
work patterns.
EC-Declaration of Conformity
Machinery Directive
WALT one of the
E
Plunge Router
DCW600
DCW604
DCW600, DCW604
V
18
18
WALT declares that these products described under
D
DC
E
1
1
Technical Data are in compliance with:
2006/42/EC, EN60745-1:2009 +A11:2010, EN60745-2-17:2010.
Li-Ion
Li-Ion
These products also comply with Directive 2014/30/EU and
W
930
930
2011/65/EU. For more information, please contact D
rpm
16000–
16000–
the following address or refer to the back of the manual.
25500
25500
The undersigned is responsible for compilation of the technical
1 column
2 columns
file and makes this declaration on behalf of D
mm
55
55
mm
8
8
30
30
kg
1.54
2.40
Markus Rompel
Vice-President Engineering, PTE-Europa
WALT, Richard-Klinger-Straße 11,
D
E
dB(A)
73
73
D-65510, Idstein, Germany
dB(A)
84
84
15.03.2019
dB(A)
3
3
m/s
4.7
4.7
2
Definitions: Safety Guidelines
m/s
2.7
2.7
2
The definitions below describe the level of severity for each
signal word. Please read the manual and pay attention to
these symbols.
WARNING: To reduce the risk of injury, read the
instruction manual.
DANGER: Indicates an imminently hazardous
situation which, if not avoided, will result in death or
serious injury.
WARNING: Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.
CAUTION: Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury.
NOTICE: Indicates a practice not related to
personal injury which, if not avoided, may result in
property damage.
Denotes risk of electric shock.
Denotes risk of fire.
ENGLISH
WALT at
E
WALT.
E
33

Advertisement

loading

Summary of Contents for DeWalt DCW600N-XJ

  • Page 1 ENGLISH PLUNGE ROUTER DCW600, DCW604 Congratulations! EC-Declaration of Conformity You have chosen a D WALT tool. Years of experience, thorough Machinery Directive product development and innovation make D WALT one of the most reliable partners for professional power tool users. Technical Data Plunge Router DCW600 DCW604...
  • Page 2 ENGLISH Batteries Chargers/Charge Times (Minutes) Weight (kg) DCB104 DCB107 DCB112 DCB113 DCB115 DCB118 DCB132 DCB119 Cat # DCB546 18/54 6.0/2.0 1.05 DCB547 18/54 9.0/3.0 1.46 135* 135* DCB548 18/54 12.0/4.0 1.44 DCB181 0.35 DCB182 0.61 60/40** 60/40** DCB183/B 0.40 DCB184/B 0.62 75/50** 75/50**...
  • Page 3 ENGLISH h ) Do not let familiarity gained from frequent use of contacts eyes, additionally seek medical help. Liquid tools allow you to become complacent and ignore ejected from the battery may cause irritation or burns. tool safety principles. A careless action can cause severe e ) Do not use a battery pack or tool that is damaged or injury within a fraction of a second.
  • Page 4 ENGLISH Electrical Safety • ALWAYS remove the battery before making adjustments or changing bits. The electric motor has been designed for one voltage only. • Keep hands clear of bits when motor is running to Always check that the battery pack voltage corresponds to the prevent personal injury.
  • Page 5 ENGLISH To remove the battery pack from the charger, push the power supply when there is no battery pack in the cavity. battery release button  2  on the battery pack. Unplug charger before attempting to clean NOTE: To ensure maximum performance and life of lithium-ion •...
  • Page 6 ENGLISH drywall screws (purchased separately) at least 25.4 mm long battery pack. Do not use a battery pack or charger that with a screw head diameter of 7–9 mm, screwed into wood to has received a sharp blow, been dropped, run over or an optimal depth leaving approximately 5.5 mm of the screw damaged in any way (i.e., pierced with a nail, hit with exposed.
  • Page 7 ENGLISH Transporting the FLEXVOLT Battery Do not expose to water. The D WALT FLEXVOLT battery has two modes: Use and Transport. Use Mode: When the FLEXVOLT battery stands alone or is in Have defective cords replaced immediately. WALT 18V product, it will operate as an 18V battery. When the FLEXVOLT battery is in a 54V or a 108V (two 54V batteries) Charge only between 4 ˚C and 40 ˚C.
  • Page 8 ENGLISH 1 Li-Ion battery pack (C1, D1, L1, M1, P1, S1, T1, X1, Y1 models) DO NOT use under wet conditions or in the presence of flammable liquids or gases. 2 Li-Ion battery packs (C2, D2, L2, M2, P2, S2, T2, X2, Y2 models) DO NOT let children come into contact with the tool.
  • Page 9 ENGLISH the Motor from the Plunge Base (if needed). 1. Open the locking lever  (fixed base) or   (plunge base).  12   40  2. Clean and insert the round shank of the desired router bit 2. Using a hex wrench turn locking lever adjustment screw   24 ...
  • Page 10 ENGLISH Installing a Plunge Base Parallel Fence with 4. Attach hose adaptor to dust extraction system attachment. When using dust extraction system attachment, be aware of Guide Rods, DCW604 Only (Fig. H) the placement of the dust extraction system. Be sure the dust A parallel fence with guide rods may be included with your extraction system is stable and its hose will not interfere with plunge base unit.
  • Page 11 ENGLISH 2. Open the plunge base locking lever   40  WARNING: Do not change the turret stop while the router is running. This will place your hands too near the 3. Making sure the spindle lock button is facing front, insert the cutter head.
  • Page 12 ENGLISH Cutting with the Fixed Base (Fig. C) Variable Speed Control (Fig. A) This router is equipped with a variable speed dial   4  with 7 Set up the router to use the fixed base by following the speeds between 16000 and 25500 RPM. Adjust the speed by instructions in the Assembly and Adjustments section.
  • Page 13 ENGLISH Cleaning WARNING: Blow dirt and dust out of the main housing with dry air as often as dirt is seen collecting in and around the air vents. Wear approved eye protection and approved dust mask when performing this procedure. WARNING: Never use solvents or other harsh chemicals for cleaning the non-metallic parts of the tool.

This manual is also suitable for:

Dcw604Dcw600