Thank you for purchasing the Smart Wireless Oxygen in Air Sensor. We pride ourselves on producing high quality products that meet with the demands of the busy classroom environment. If you have any problems using this sensor, please read this documentation in full before contacting the Data Harvest support team.
1170 - Wireless Oxygen In Air Sensor Manual Pack Contents This product is supplied with the following items: · 1 x Smart Wireless Oxygen in Air Sensor · 1 x USB Connecting Lead · 1 x Nalgene Bottle Additional Accessories...
1170 - Wireless Oxygen In Air Sensor Manual Operational Overview The diagram below shows the specific parts of the sensor. Read further to explore the functionality of each part of the sensor. 1.Sensor End Cap 2.Status Indicator 3.On/Off Switch 4.USB Port 5.Unique ID Number...
Page 6
· Press and hold down the On/Off button for at least 8 seconds until the status LED gives a flash of blue light, then release. · If the sensor fails to respond, contact Product Support at Data Harvest. Please provide details of: The computer platform it is being used with and the EasySense2 app’s version number.
1170 - Wireless Oxygen In Air Sensor Manual Connectivity The sensor is both USB and Bluetooth compatible. Install the EasySense2 app, if it is not already on your device. For details of how to operate the EasySense2 app, please refer to the EasySense2 documentation.
1170 - Wireless Oxygen In Air Sensor Manual Charging the Sensor The Smart Wireless sensors are fitted with a rechargeable lithium-ion battery and can be charged via the USB port. Use the supplied USB lead to connect the sensor either directly to a USB port on your computer, a powered USB hub or a USB mains charger that outputs 5 V at 500 mA or more.
The sensor can be calibrated in the EasySense2 App. Firmware Updates Occasionally Data Harvest may release updated firmware which will contain improvements or new features. Updates will take place when you connect your sensor to the EasySense2 app. You will be given the option to decline an update.
1170 - Wireless Oxygen In Air Sensor Manual Usage Information Please read the following guidelines carefully before using this sensor · The sensor is an electrochemical sensor, in effect it is like a battery, it will need replacing at approximately 5 years. The exact duration of the sensor will depend upon storage temperature and correct storage.
1170 - Wireless Oxygen In Air Sensor Manual Practical Investigations The Oxygen In Air Sensor can be used to investigate a number of scientific experiments such as: · Monitoring human respiration in inhaled and exhaled air · Exhaled breath before and after exercise ·...
Page 12
1170 - Wireless Oxygen In Air Sensor Manual Explore Science Practicals See our Smart Wireless Sensors in action with a range of practical experiments. This is the best way to get started with the new Bluetooth sensors! View video playlist...
1170 - Wireless Oxygen In Air Sensor Manual Sensor Specifications Please read the following table for sensor specifications. Feature Detail Measurement Ranges O2: 0 to 100 % Temperature: -40 to 85̊ C Pressure: 30 to 110 kPa Humidity: 0 to 100 %RH Resolution O2: 0.1%...
Postage Charges · In the event of a fault developing, the product must be returned in suitable packaging to Data Harvest for repair or replacement at no expense to the user other than postal charges. · There will be no postal charge for the return of repaired goods to any mainland UK address (for other areas, additional shipping charges may apply).
Waste Electrical and Electronic Equipment Legislation Data Harvest Group Ltd is fully compliant with WEEE legislation and is pleased to provide a disposal service for any of our products when their life expires. Simply return them to us clearly identified as ‘life expired’...
1170 - Wireless Oxygen In Air Sensor Manual Troubleshooting If you experience any problems with your product, please try the following troubleshooting tips before contacting the Data Harvest support team. Feature Detail If the sensor loses Bluetooth connection and Loss of Bluetooth Connectivity will not reconnect try: Closing and reopening the EasySense 2 app.
3. When the sensor is connected to a computer, the computer should be turned on and not in sleep or standby mode or the battery may drain instead of charge. 4. Data Harvest products are designed for educational use and are not intended for use in industrial, medical or commercial applications.
1170 - Wireless Oxygen In Air Sensor Manual Contact Information To contact Data Harvest directly, please use any of the following channels Traditional Communications Data Harvest Group Ltd. 1 Eden Court, Eden Way, Leighton Buzzard, Bedfordshire, LU7 4FY United Kingdom...
1170 - Wireless Oxygen In Air Sensor Manual PDF Translations The PDF formatted download of this manual is by default provided in the English (United Kingdom) language. If an alternative translation is available, it will be listed here. We have for your convenience included a webpage translation feature to the online documentation which will allow you to translate and print individual pages of this documentation.