Networking
6.3 Network configuration
6.3.3

Networks with NCU connection to the company network

6.3.3.1

Configuration 2: NCU and TCU

The TCU is directly connected to the NCU via a crossed Ethernet cable. On X130, the NCU is
connected to a switch to the company network with a straight cable.
As in configuration 1, there is a direct Ethernet connection between a TCU and X120 of the
NCU. NCU and TCU are suitably preconfigured with IP addresses. The IP addresses used here
are not significant for further operation.
IP configuration: DHCP server on the company network
On the X130, the NCU is set to the address reference via DHCP. If the company network has a
DHCP server that provides the NCU with an IP address/configuration, the NCU is integrated in the
company network.
Depending on the infrastructure available or the level of network administration of the
company network, the following network parameters must be set for the NCU on X130:
• Computer name on the company network
• The address of a DNS server
• The address of a gateway (default router)
The IP address of the NCU on this connection is also assigned via the network administration.
If the company network offers a low level of administration, in the worst case scenario the
network has only one DHCP server that assigns the addresses from a predefined address
range, the NCU receives an IP address that is initially unknown.