hit counter script

Data Harvest 1207 Manual

Wireless uv sensor

Advertisement

Quick Links

1207 – Wireless UV Sensor
Revision: 0 | DS182
© Copyright Data Harvest Group Ltd - All Rights Reserved - Freely photocopiable for use within the purchaser's
establishment

Advertisement

Table of Contents
loading

Summary of Contents for Data Harvest 1207

  • Page 1 1207 – Wireless UV Sensor Revision: 0 | DS182 © Copyright Data Harvest Group Ltd - All Rights Reserved - Freely photocopiable for use within the purchaser’s establishment...
  • Page 2: Table Of Contents

    1207 – Wireless UV Sensor Table of contents Introduction ...................... 3 Pack Contents ....................5 Operational Overview ..................6 Connectivity ...................... 8 Charging the Sensor ................... 9 Firmware Updates .................... 10 Usage Information .................... 11 Practical Investigations ..................12 Sensor Specifications ..................14 Limited Warranty .....................
  • Page 3: Introduction

    Thank you for purchasing the Smart Wireless UV Sensor. We pride ourselves on producing high quality products that meet with the demands of the busy classroom environment. If you have any problems using this sensor, please read this documentation in full before contacting the Data Harvest support team.
  • Page 4 1207 – Wireless UV Sensor The Ultraviolet Sensor measures UV light intensity as irradiance in W/m2. There are other ways that UV intensity and exposure are measured. e.g. 1. The Ultraviolet Index (UVI), which is a measure of the solar ultraviolet (UV) intensity at the Earth's surface relevant to the effect on human skin.
  • Page 5: Pack Contents

    1207 – Wireless UV Sensor Pack Contents This product is supplied with the following items: · 1 x Smart Wireless UV Sensor · 1 x USB Connecting Lead 5 / 20 | Revision: 0 | DS182...
  • Page 6: Operational Overview

    1207 – Wireless UV Sensor Operational Overview The diagram below shows the specific parts of the sensor. Read further to explore the functionality of each part of the sensor. 1.Sensor End Cap 2.Status Indicator 3.On/Off Switch 4.USB Port 5.Unique ID Number...
  • Page 7 · Press and hold down the On/Off button for at least 8 seconds until the status LED gives a flash of blue light, then release. · If the sensor fails to respond, contact Product Support at Data Harvest. Please provide details of:  The computer platform it is being used with and the EasySense2 app’s version number.
  • Page 8: Connectivity

    1207 – Wireless UV Sensor Connectivity The sensor is both USB and Bluetooth compatible. Install the EasySense2 app, if it is not already on your device. For details of how to operate the EasySense2 app, please refer to the EasySense2 documentation.
  • Page 9: Charging The Sensor

    1207 – Wireless UV Sensor Charging the Sensor The Smart Wireless sensors are fitted with a rechargeable lithium-ion battery and can be charged via the USB port. Use the supplied USB lead to connect the sensor either directly to a USB port on your computer, a powered USB hub or a USB mains charger that outputs 5 V at 500 mA or more.
  • Page 10: Firmware Updates

    1207 – Wireless UV Sensor Firmware Updates Occasionally Data Harvest may release updated firmware which will contain improvements or new features. Updates will take place when you connect your sensor to the EasySense2 app. You will be given the option to decline an update.
  • Page 11: Usage Information

    1207 – Wireless UV Sensor Usage Information Ordinary glass can cut off some UV that has a wavelength less than 300 nm.  An appropriate UV light source would be within the UV-A band because it’s the least hazardous UV ...
  • Page 12: Practical Investigations

    1207 – Wireless UV Sensor Practical Investigations The Smart Wireless UV Sensor can be used to investigate a number of scientific experiments such as: Using the Slow range:  Absorption of ultraviolet by different types of clothing (not related to colour) ...
  • Page 13 1207 – Wireless UV Sensor Explore Science Practicals See our Smart Wireless Sensors in action with a range of practical experiments. This is the best way to get started with the new Bluetooth sensors! View video playlist 13 / 20 | Revision: 0 | DS182...
  • Page 14: Sensor Specifications

    1207 – Wireless UV Sensor Sensor Specifications Please read the following table for sensor specifications. Feature Detail Slow response ranges: Measurement Ranges 0 - 500 mW/m2, Resolution: <0.2 mW/m2 0 - 5 W/m2, Resolution: <0.002 W/m2 0 - 50 W/m2, Resolution: <0.02 W/m2 Fast response ranges: 0 - 500 mW/m2, Resolution: <0.2...
  • Page 15: Limited Warranty

    Postage Charges  In the event of a fault developing, the product must be returned in suitable packaging to Data Harvest for repair or replacement at no expense to the user other than postal charges.  There will be no postal charge for the return of repaired goods to any mainland UK address (for other areas, additional shipping charges may apply).
  • Page 16: Compliance

    Waste Electrical and Electronic Equipment Legislation Data Harvest Group Ltd is fully compliant with WEEE legislation and is pleased to provide a disposal service for any of our products when their life expires. Simply return them to us clearly identified as ‘life expired’...
  • Page 17: Troubleshooting

    1207 – Wireless UV Sensor Troubleshooting If you experience any problems with your product, please try the following troubleshooting tips before contacting the Data Harvest support team. Feature Detail If the sensor loses Bluetooth connection and Loss of Bluetooth Connectivity will not reconnect try: Closing and reopening the EasySense 2 app.
  • Page 18: Notices

    2. When the sensor is connected to a computer, the computer should be turned on and not in sleep or standby mode or the battery may drain instead of charge. 3. Data Harvest products are designed for educational use and are not intended for use in industrial, medical or commercial applications.
  • Page 19: Contact Information

    1207 – Wireless UV Sensor Contact Information To contact Data Harvest directly, please use any of the following channels Traditional Communications Data Harvest Group Ltd. 1 Eden Court, Eden Way, Leighton Buzzard, Bedfordshire, LU7 4FY United Kingdom Tel: +44 (0) 1525 373666...
  • Page 20: Pdf Translations

    1207 – Wireless UV Sensor PDF Translations The PDF formatted download of this manual is by default provided in the English (United Kingdom) language. If an alternative translation is available, it will be listed here. We have for your convenience included a webpage translation feature to the online documentation which will allow you to translate and print individual pages of this documentation.

Table of Contents