DCS302 GENERAL INFORMATION GENERAL The DCS302 is a dual cylinder scale designed specifically for the water and wastewater industry. The scale base and weighing surfaces are made of Type 2 PVC plastic and are guaranteed for five years against environmental damage.
Page 3
Make wiring connections as shown on pages 13 and 14 of the "EI-2000 Dual Channel Weight & Level Display/Transmitter Operating Manual" for the "DCS302 Dual Cylinder Scale". 6. Follow instructions in the Operating Manual for startup and calibration of the EI-2000.
Page 7
TEST PROCEDURES DCS302 DUAL CYLINDER LOAD CELL SCALE 1. After assembly a known weight of 250 lbs. is alternately placed on each platform and removed two times in order to flex the components of the scale base. 2. Upon loading the scale for the third time, the display of the EI-2000 indicator allowed to stabilize.
Page 11
DCS-302 Load Cell Replacement Remove four screws holding the lid. Disconnect the load cell that needs to be replaced from the terminal block. Loosen the strain relief on the bottom of the divider plate and pull the wire through. Load cells and adjustment bolt pictured below for reference. Note how high the bolt is above the nut on your scale.
Page 12
Use pliers to hold the bolt under the load cell and remove the nut. Don’t let the bolt fall through the deck or you will need to unbolt the scale from the floor to retrieve it. Loosen the setscrew holding the load cell. Remove the cell. Check the new load cell.