Page 1
INSTALLATION AND USER MANUAL pag.25 O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice. Edition 2003.06 No reproduction, however partial, is permitted. Via Cave, 7/9 25050 Provaglio d’Iseo (Brescia) Italy Tel.: +39.030.9830611 Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:contatti@omfb.it...
1. RADAR II Midi transmitter (to control 2- and 4-channel systems) 2. RADAR NEW TXF transmitter (to control 2- to 12-channel systems) The OMFB RADAR II system is completely modular, and up to 10 different configurations may be obtained by combining the above components appropriately.
“RADAR II” USER MANUAL 101-050 1.3 RADAR II 2-channel receiver, trailer configuration Emergency Button Start Button Manual control buttons 1.4 RADAR II 4-channel receiver Emergency Button Start Button Manual control buttons channels 1,2 Manual control buttons channels 3,4 pag.28 O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice.
“RADAR II” USER MANUAL 101-050 1.5 RADAR II Midi transmitter To control configurations with 2, 2+2, or 4 channels. Transmitting LED Function buttons EMERGENCY STOP/Emergency push-button pag.29 O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice.
A, B or C receiver pag.30 O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice. Edition 2003.06 No reproduction, however partial, is permitted. Via Cave, 7/9 25050 Provaglio d’Iseo (Brescia) Italy Tel.: +39.030.9830611 Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:contatti@omfb.it...
USER MANUAL 101-050 1.7 Product Markings and certification RADAR II radio remote controls meets the rules set forth in the following harmonised technical standards: • EN 300 220 - 3:2000 for Effective Use of Spectrum; • EN 301 489 - 3:2000 for Electromagnetic Compatibility;...
Page 8
Compliance is shown by product marking: 03 1732 Compliance of RADAR II radio remote controls with the ECE/ONU Reg. No 10 Add. 9 requirements is certified by the Notified Body NSAI4 by releasing the approval number for the product marking: E24 10R-020012.
2. O RDERING CODES FOR RADIO REMOTE CONTROLS AND SPARE PARTS 2.1 Ordering codes The “RADAR II” Radio Remote Control may be supplied in the following models: • With RADAR II Midi transmitter: - 10105050050: 2 channel radio remote control...
“RADAR II” USER MANUAL 101-050 3. T ECHNICAL SPECIFICATIONS 3.1 RADAR II Midi transmitter apparatus (Regarding the RADAR NEW TXF transmitter, consult the enclosed manual) POWER SUPPLY Battery type 6LR61 9 V ABSORBED CURRENT Max 12-15 mA SPURIOUS EMISSIONS (vs. BASIC)
4. E LECTRICAL SPECIFICATIONS 4.1 Power supply RADAR II radio remote controls may be powered with a voltage between 10V and 28V in direct current. The power supply line (+12/24V batt and ground) should lead to the receiver directly from the main source (battery or stabilized power source), with cables adequately sized for the load to be carried (cross-section of at least 1 mm^2), also using a safety fuse.
The typical device configuration of OMFB radio remote controls is to control systems made up of electric pumps and solenoid valves. The OMFB Radar II receiver is equipped with a series of 4 microswitches, shown in the figure: each microswitch allows the installer to set, for each individual output, the function as double-acting or single-acting, thus it allows the installer to define whether or not the AUX output must be enabled parallel with each individual output.
• 1 AUX output (see 4.3 for more informa- tion) with a maximum absorption of 8 A. Radar II 2 CH RIM Receiver • 2 outputs to activate electrical devices (such as solenoid valves or relays), with a maximum absorption of 8 A each. The...
(8 A on one output and 8 A on the AUX output). Where the loads are actually close to this limit, we suggest checking with the OMFB staff to determine whether the type of load may create problems: the information to report includes: type of load (coil, solenoid valve, remote switch, etc.), electrical specifications...
Do not drill any holes in the box, under penalty of voiding the product warranty. pag.40 O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice. Edition 2003.06 No reproduction, however partial, is permitted. Via Cave, 7/9 25050 Provaglio d’Iseo (Brescia) Italy Tel.: +39.030.9830611 Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:contatti@omfb.it...
5.5 Installing multiple side-by-side receivers In the RADAR II 2CH+2CH, 6 CH, 8 CH, 10 CH and 12 CH configurations, which involve multiple receivers installed side by side, these must be installed at a minimum distance of 30 mm from one another.
O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice. Edition 2003.06 No reproduction, however partial, is permitted. Via Cave, 7/9 25050 Provaglio d’Iseo (Brescia) Italy Tel.: +39.030.9830611 Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:contatti@omfb.it...
Page 19
O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice. Edition 2003.06 No reproduction, however partial, is permitted. Via Cave, 7/9 25050 Provaglio d’Iseo (Brescia) Italy Tel.: +39.030.9830611 Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:contatti@omfb.it...
“RADAR II” USER MANUAL 101-050 8.2 Functional testing procedure of the RADAR II receiver unit Functional test procedure for RADAR II receiver unit Start Power up the receiver unit Request a return indicating "Possible problems on the power supply line"...
• The battery connection is intact and ensures electrical contact; pag.46 O.M.F.B. S.p.A. Hydraulic Components We reserve the right to make any changes without notice. Edition 2003.06 No reproduction, however partial, is permitted. Via Cave, 7/9 25050 Provaglio d’Iseo (Brescia) Italy Tel.: +39.030.9830611 Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:contatti@omfb.it...
Page 23
IS IT POSSIBLE TO DISABLE THE AUXILIARY SIGNAL WHEN ONE OF THE TWO OR FOUR OUTPUTS IS ACTIVATED? Yes, but this operation may be carried out only by the engineers of OMFB SpA Hydraulic Components, by placing the request directly together with the order, or as a subsequent alteration, referring to “Single-acting”.