INTRODUCTION This manual is issued specifically for the data processing racks of the TA3840 or EMx40 system. It contains instructions detailed for the installation of this system. To use it in an optimal way, we advise you TO READ CAREFULLY THESE INSTRUCTIONS and to respect them throughout the life of the equipment.
Page 4
The safety instructions given in this manual are merely given for guidance purposes to protect you and all those using and working on our equipments. Honeywell Marine cannot foresee all dangerous situations that might arise. This is why the owner and/or the operator is responsible for the operating safety of the system.
4-20 mA analog inputs board ....................17 Multifunction board ........................20 TA3840S CPU board (optional) ....................21 Configuration ..........................21 TA3840R CPU board (optional) ....................22 7. COMMISSIONING ........................22 8. APPENDIX B - TA3840 SYSTEM / RETURN FOR REPAIR FORM ........... 23...
Take care not to damage the front panel with LCD screen and keyboard of the communication unit and remote display unit (if present). Storage There is no particular requirement. The storage temperature of the TA3840 system is 0 °C to +70 °C. 2. SYSTEM DESCRIPTION...
3. INSTALLATION OF THE RACKS If the racks are not pre-mounted in a cabinet supplied by Honeywell Marine, they must be installed in a standard 19" frame. ● Introduce each rack in its housing. ● Fix it with the 4 screws provided for this purpose (flat screwdriver).
Page 8
If the rack is delivered in a cabinet by Honeywell Marine, connecting points 1, 2 and 4 are pre-wired. Connect the supply cable 24 Vdc to the terminal block, respecting the polarity. WARNING : The TA3840C is powered by 24 Vdc.
Page 9
Imperatively connect all cable shielding to the grounding bar. Connect a metal braid between the grounding bar and the metallic frame in which the racks are installed. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
25 to 48 49 to 72 73 to 96 If the rack is delivered in a cabinet by Honeywell Marine, connecting points 1 and 4 are pre-wired. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks...
Page 11
Imperatively connect all cable shielding to the grounding bar. Connect a metal braid between the grounding bar and the metallic frame in which the racks are installed. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
● Check the On/Off switch on the front panel is in "Off" position. If the rack is delivered in a cabinet by Honeywell Marine, connecting points 1 and 2 are pre-wired. Connect the mains supply cable to the terminal block (neutral and phase wires) using wires max. 3 x 2.5 mm².
Page 13
RS485 Þ connect the cable, respecting the identification of A, B and ground wires. The CPU board must be configured according to the transmitter type (refer to "Configuration of the boards" chapter). Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
Connect the dry contact output for alarms (data and system). The jumpers of the remote display unit electronic board are factory pre-set and must not be moved. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
(option), or multifunction boards (option) TA3840C A/D - Data collection unit Only the items 1 and 3 are present. The front panel is blind. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
4 communication ports. JP2/ JP6/ JP10/ JP12 JP13 JP16 JP14/ ● Position the jumpers according to the communication type for relevant port. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
A series of jumpers (JP) placed on the electronic board is used to select the transmitter type and channel numbers. They are factory pre-set and must not be moved. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
Page 18
17 to 24 25 to 32 33 to 40 41 to 48 The jumper's position is given with the connector of the electronic board on the right side. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
Page 19
Addresses Close Close Close Close Open Open Open Open Close Close Open Open Close Close Open Open JP10 Close Open Close Open Close Open Close Open Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
- JP1 must be placed down for 2 wires transmitters. The jumper position is given with the connector of the electronic board on the right side. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
The jumper's position is given with the connector of the electronic board on the right side. ● ST3 is factory pre-set and must not be moved. Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
TA3840C rack and radar transmitters commissioning are carried out using the COM3840 software. System use is described in the chapter "Operation in normal mode" of the technical manual MT5008E Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
8. APPENDIX B - TA3840 SYSTEM / RETURN FOR REPAIR FORM Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
Page 24
Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
Page 25
Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
Page 26
Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...
Page 27
92266 FONTENAY AUX ROSES (France) Bourges, le 15 mars 2013 L. MAUDUIT Responsable Technique dûment autorisé à signer Bourges, March 15 , 2013 Technical Manager with legally effective signature Doc No: MI5008E – Revision 7 – ENG Data Processing Racks TA3840 Installation Manual...