Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Preface Preface This guide describes the RUGGEDCOM WIN5237-IS. It describes the major features of the subscriber unit, installation, commissioning and important technical specifications. It is intended for use by subscriber unit installers and operators, and assumes readers have a working knowledge of WiMAX technologies and procedures.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
Introduction Introduction The RUGGEDCOM WIN5237-IS subscriber unit is part of the RUGGEDCOM WIN family, a line of mobile WiMAX broadband wireless access systems based on the IEEE 802.16e mobile WiMAX standard. The RUGGEDCOM WIN5237-IS is a high-performance, self-learning subscriber. It automatically detects the base station on the best signal available, allowing for plug-and-play installation and maintenance free operation.
The subscriber unit supports both IP convergence sublayer for wireless Internet service providers or Ethernet Convergence Sublayer, ideal for mission critical private networks. Section 1.2 Description The RUGGEDCOM WIN5237-IS features various ports, controls and indicator LEDs on the bottom panel for connecting, configuring and troubleshooting the subscriber unit. Feature Highlights...
Page 9
RUGGEDCOM WIN5237-IS Chapter 1 Installation Guide Introduction ETH/PWR RSSI W.LINK PWR RSSI W.LINK PWR Figure 1: RUGGEDCOM WIN5237-IS 1. RSSI LEDs 2. W.LINK LED 3. PWR LED 4. ETH/PWR Port 5. Chassis Ground RSSI LEDs Indicates the received signal strength. RSSI Level < -90 -85 to -90...
Section 2.5, “Grounding the Subscriber Unit”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM WIN5237-IS: Tools Greases • Wrench or socket set • Marine grease (for marine applications only) • Phillips screwdriver Tapes •...
WARNING! Safety hazard – risk of serious personal injury and/or damage to equipment. Installing the RUGGEDCOM WIN5237-IS can pose a serious safety hazard. Be sure to take precautions to avoid the following: • Exposure to high voltage lines during installation •...
Chapter 2 RUGGEDCOM WIN5237-IS Installing the Subscriber Unit Installation Guide IMPORTANT! This product should be installed in a restricted access location where access can only be gained by authorized personnel who have been informed of the restrictions and any precautions that must be taken.
Configure the subscriber unit. For more information, refer to Section 3.1, “Configuring the Subscriber Unit”. Section 2.2 Unpacking the Subscriber Unit The following items are included in the RUGGEDCOM WIN5237-IS package: Item Quantity RUGGEDCOM WIN5237-IS Subscriber Unit RUGGEDCOM WIN1010 AC Power Injector Radio Frequency (RF) antenna cables, 5 m (16.4 ft) long...
Do not attempt to touch or remove the component. Section 2.4 Mounting the Subscriber Unit The RUGGEDCOM WIN5237-IS is designed for maximum mounting and display flexibility. It can be secured to a bracket and then mounted to a pole, wall or tower. Mounting the Subscriber Unit...
RUGGEDCOM WIN5237-IS Chapter 2 Installation Guide Installing the Subscriber Unit NOTE For detailed dimensions of the subscriber unit, refer to Section 4.6, “Dimension Drawings”. When choosing the mounting location for the unit, consider the available mounting structures and antenna clearance. Site Survey Most wireless networks include many subscriber/base stations installed in various locations in an overlapping...
Page 16
Chapter 2 RUGGEDCOM WIN5237-IS Installing the Subscriber Unit Installation Guide Figure 2: Mounting the Subscriber Unit to a Wall or Tower 1. Subscriber Unit 2. Mounting Kit 3. Wall Holder/Pole Mount 4. M8 × 25 mm Hex Screw 5. M8 Spring Washer 6. M8 Flat Washer 7. M8 Nut 8. M5 Flat Washer 9. NS 1/4" × 1/2" HEX Chipboard Screw 10. Wall Anchor Liberally apply an anti-corrosion spray to all galvanized steel components, including mounting brackets, washers and screws.
RUGGEDCOM WIN5237-IS Chapter 2 Installation Guide Installing the Subscriber Unit If the subscriber unit is not synchronized with the base station, make sure the subscriber unit is properly configured. For more information, refer to the RUGGEDCOM WIN User Guide for the RUGGEDCOM WIN5237- If the expected link quality still cannot be achieved, try to improve the reception quality by placing the subscriber unit at a higher point or in an alternate location.
Page 18
Chapter 2 RUGGEDCOM WIN5237-IS Installing the Subscriber Unit Installation Guide Figure 4: Mounting the Subscriber Unit to a Small Pole 1. Subscriber Unit 2. Pole 3. Clamping Bracket 4. Mounting Bracket 5. M8-25 Hex Screw 6. M8 Spring Washer 7. M8 Flat Washer 8. M8 Nut 9. M8-70 Hex Screw Liberally apply an anti-corrosion spray to all galvanized steel components, including mounting brackets, nuts, washers and screws.
RUGGEDCOM WIN5237-IS Chapter 2 Installation Guide Installing the Subscriber Unit 10. Tighten the screws connecting the clamping bracket to the mounting bracket. Make sure the screws are torqued to 14 N·m (10 lbf-ft). Section 2.5 Grounding the Subscriber Unit When connecting the ground cable to the subscriber unit, make sure to use a 10 AWG grounding cable and torque the screw to 15 N·m (11 ft.
Connecting to a RUGGEDCOM RP100 or RP110 The RUGGEDCOM RP100 and RP110 are optional power injectors for powering and providing data to the RUGGEDCOM WIN5237-IS. The RUGGEDCOM RP100 and RP110 meet a wider temperature and voltage range than the standardRUGGEDCOM WIN1010.
The lightning protector must meet the necessary requirements of IEC/UL/CSA 60950-1. The clamping voltage must also be less than 60 V and the protector must not activate when the voltage is less than 56 V. For more information about these requirements, contact Siemens Customer Support. IMPORTANT! Install the lightning protector and the RUGGEDCOM RP100/RP110 as close as possible.
Page 22
Chapter 2 RUGGEDCOM WIN5237-IS Installing the Subscriber Unit Installation Guide Figure 7: Assembling the Connector Components 1. Plug Housing 2. Dust Cover Strip the wire jacket 38 mm (1.5 in) from the tip, making sure not to cut the foil or drain wire. 38 mm (1.5 in)
Page 23
RUGGEDCOM WIN5237-IS Chapter 2 Installation Guide Installing the Subscriber Unit Figure 10: Bending the Drain Wire 1. Foil 2. Drain Wire 3. Twisted-Pair Wires Partially untwist each wire pair, making sure to retain a half twist at the end. Figure 11: Untwisting the Wire Pairs Arrange the wires according to the following pin-out description:...
Page 24
Chapter 2 RUGGEDCOM WIN5237-IS Installing the Subscriber Unit Installation Guide Figure 13: 1. Loading Bar 2. Wires 3. Pin 1 4. Pin 8 Trim the wires until they are flush with the face of the loading bar. Insert the wires and loading bar into the plug body. Make sure: •...
Most outdoor subscriber unit, antenna and cable problems are caused by coaxial cable connections loosened by vibration, allowing moisture to penetrate the connector interface. Siemens strongly recommends weatherproofing all outdoor cable connections to prevent the ingress of water and help secure connections.
Chapter 2 RUGGEDCOM WIN5237-IS Installing the Subscriber Unit Installation Guide If the subscriber unit is installed in a marine environment (e.g. wind farm substation, coastal tower, or marine vessel) apply a coating of marine grease to all galvanized steel components, including mounting brackets, nuts, washers and screws.
RUGGEDCOM WIN5237-IS Chapter 3 Installation Guide Device Management Device Management This section describes how to connect to and manage the subscriber unit. CONTENTS • Section 3.1, “Configuring the Subscriber Unit” Section 3.1 Configuring the Subscriber Unit Once the subscriber unit is installed and connected to the network, it must be configured. The RUGGEDCOM WIN5237-IS features a Web-based User Interface (UI) for all configuration management.
-20 to 100 dBm Dynamic Range (Transmitter) -20 to 27 dBm Section 4.3 Operating Environment The RUGGEDCOM WIN5237-IS is rated to operate under the following environmental conditions. Ambient Operating -40 to 75 °C (-40 to 167 °F) Temperature Ambient Storage Temperature -40 to 75 °C (-40 to 167 °F)
Page 31
RUGGEDCOM WIN5237-IS Chapter 4 Installation Guide Technical Specifications Conductor Size 0.52 mm Outer Jacket Material UV resistant FR-PVC Outer Diameter 7.9 mm (0.31 in) nominal Weight 68.0 kg/km IDU to ODU Cable Design and Materials Conductor Material Bare Copper Conductor Size...
Chapter 4 RUGGEDCOM WIN5237-IS Technical Specifications Installation Guide Dielectric Strength to Shield 700 V/minute Minimum Bend Radius 70 mm (2.8 in) Operating Temperature Range -40 to 70 °C (-40 to 158 °F) Section 4.6 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated.
RUGGEDCOM WIN5237-IS Chapter 5 Installation Guide Certification Certification The RUGGEDCOM WIN5237-IS ODU SU has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 5.1, “Approvals” • Section 5.2, “Environmental Type Tests”...
Installation Guide Section 5.1.2 European Union (EU) This subscriber unit is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: • IEC/EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements Section 5.1.3...
Mobile Operation in Licensed Bands Section 5.1.6 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Page 36
Chapter 5 RUGGEDCOM WIN5237-IS Certification Installation Guide Test Description Test Levels IEC 529 (IP65/IP67) Water (Rain) 0.01 m³/min @ 90 kPa (13 PSI) for 15 minutes IEC 60068-2-6 Sine Vibration Velocity: 5 mm/s Displacement: 1.5 mm Acceleration: 2 m/s² Frequency Range: 5 to 62 Hz, 62 to 200 Hz...