Copying settings by page
1
In the Engineering Setup >Panel >Operation >Xpt
Module Operation menu (7326.12), press [Xpt Pad
Page Copy].
The Xpt Pad Page Copy menu (7326.19) appears.
2
In the list on the left, select the copy source cross-point
pad page.
3
In the list on the right, select the copy destination
cross-point pad page.
4
Press [Copy].
To switch to page name display
Press [Page Name Display], turning it on. The name is
displayed instead of the page number.
Setting the Display Mode of the
Cross-Point Control Block/AUX Bus
Control Block
This sets the information that appears on the display of the
cross-point control block/AUX bus control block.
The display content and format can be selected for each of
six types of display mode.
1
In the Engineering Setup >Panel >Operation >Xpt
Module Operation menu (7326.12), press [Display
Mode Setting].
The Display Mode Setting menu (7326.15) appears.
The left side of the status area shows six display
modes, and the right side shows a list of items to
display.
2
In the <Bank Select> group, select the target bank to
set.
3
Select the target display mode to set.
4
To divide the display into upper/lower to display two
pieces of information, press [Split], turning it on.
5
In the list on the right, select the item to display.
6
Perform the following operations.
• When [Split] is not lit, press [Set] in the <Lower
Area> group.
• When [Split] is lit, press [Set] in the <Upper Area>
group to set the display in the upper area, and in the
<Lower Area> group to set the display in the lower
area.
To make the display background gray
In the <Upper Area> group or <Lower Area> group, press
[Gray Bkgd], turning it on.
To rename a display mode
The specified name is displayed on the display mode
buttons in the cross-point pad used for display mode
selection.
1
Select the target display mode to set, and press
[Name].
2
Enter a name of up to 12 characters in the keyboard
window, and press [Enter].
Note
Lower case characters may be entered, but the entered
characters are displayed as upper case characters on
the buttons in the cross-point pad.
To return the display mode settings to the
defaults
Press [Default Recall], check the message, then press
[Yes].
Setting Utility Bus Mode
You can set the bus assigned to the 1st row to 4th row on
the cross-point control block when the [UTIL] button is
pressed on the cross-point pad.
1
In the Engineering Setup >Panel >Operation >Xpt
Module Operation menu (7326.12), press [Util Button
Bus Assign].
The Utility Button Bus Assign menu (7326.16)
appears.
The left side of the status area shows the bus currently
assigned to the 1st row to 4th row, and the right side
shows a list of assignable buses.
2
In the <Bank Select> group, select the target bank to
set.
3
In the list on the left, select the target button row to
assign.
4
In the list on the right, select the bus to assign.
5
Press [Set].
To release the assignment
Select the target button row to release, then press [Clear].
To return the 1st row to 4th row assignments to
the default
Press [Default].
437