ET 200SP HA
DI 32x24VDC HA
Equipment Manual
6DL1131-6BL00-0PH1
10/2021
A5E48262828-AB
Security information
Preface
Product overview
Connection
Parameters
Displays and interrupts
Technical specifications
Drivers, parameters,
diagnostics messages and
address space
1
2
3
4
5
6
7
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC ET 200SP HA

  • Page 1 Security information Preface Product overview SIMATIC Connection ET 200SP HA DI 32x24VDC HA Parameters Displays and interrupts Equipment Manual Technical specifications Drivers, parameters, diagnostics messages and address space 6DL1131-6BL00-0PH1 10/2021 A5E48262828-AB...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Security information..........................5 Preface ..............................7 Product overview ........................... 9 I/O module........................... 9 Accessories ........................10 Terminal blocks........................11 Terminal blocks with potential distributors (L+ potential) ............ 11 Connection............................13 Pin assignment (1-wire connection) ................... 13 Pin assignment (2-wire connection) ................... 14 Sample connection scheme for 1-wire connection ..............
  • Page 4 Table of contents Technical specifications ........................25 Drivers, parameters, diagnostics messages and address space ............29 Parameter assignment ....................... 29 Parameter assignment and structure of the module/channel parameters......30 Diagnostic messages......................32 Maintenance events......................33 Hardware interrupts ......................34 Address space ........................34 Index ..............................
  • Page 5: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
  • Page 6 Security information DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 7: Preface

    Preface Validity of the documentation This manual describes the following I/O module: System family I/O module Article No. SIMATIC; DI 32x24VDC HA 6DL1131-6BL00-0PH1 Distributed I/O System; ET 200SP HA It supplements the system manual for the ET 200SP HA distributed I/O system. Functions that generally relate to the system are described in this manual.
  • Page 8 Preface DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 9: Product Overview

    Product overview I/O module Definition The DI 32x24VDC HA I/O module is a digital input module with 32 power inputs for process control. In addition to the technical specifications, this module has the following properties: • Sink input (PNP, active power) •...
  • Page 10: Accessories

    Product overview 3.2 Accessories Description The I/O module consists of the following components: 32 x2 4V DC DI AG M T 1 DI .0 3 DI .2 DI .1 5 DI .4 DI .3 DI .5 7 DI .6 DI .7 9 DI .0 DI .1 11 DI .2...
  • Page 11: Terminal Blocks

    Product overview 3.4 Terminal blocks with potential distributors (L+ potential) • Reference identification label • Shield connector Terminal blocks Definition The terminal blocks provide the process terminals (push-in terminals) for the connection of components, such as devices. Description The following terminal blocks are available for the I/O module: Article No.
  • Page 12 Product overview 3.4 Terminal blocks with potential distributors (L+ potential) Description Use the following terminal block to connect 2-wire sensors: Article No. Function/parameter 6DL1193-6TP00-0DP0 Allow new potential group (light terminal block) 6DL1193-6TP00-0BP0 Use potential group of the left module (dark terminal block) DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 13: Connection

    Connection Pin assignment (1-wire connection) Definition The pin assignment provides information about the arrangement and identification of the terminals when wiring a connector. Description The general pin assignment is structured as follows: Terminal Assignment Terminal Assignment Explanations DI a /DI.0+ DI a /DI.1+ DI a /DI.n+: Input signal, channel n (0…7) DI b /DI.n+: Input signal, channel n+8 (8…15)
  • Page 14: Pin Assignment (2-Wire Connection)

    Connection 4.4 Example connection scheme for DI-2 wire sensor connection Pin assignment (2-wire connection) Definition The pin assignment provides information about the arrangement and identification of the terminals when wiring a connector. Description The pin assignment on the left side of the terminal blocks with potential distributor corresponds to the following assignment: Pin assignment (1-wire connection) (Page 13) The potential distributor with the following terminals is located on the right side of the terminal...
  • Page 15: Example Connection Diagram For Sensor Connection With External Power Supply

    Connection 4.6 Schematic circuit diagram Example connection diagram for sensor connection with external power supply Example This connection variant is only permitted with terminal blocks of the type "potential distributor". Schematic circuit diagram Definition A block diagram contains the schematic representation of individual function blocks. DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 16 Connection 4.6 Schematic circuit diagram Description The block diagram for the I/O module is structured as follows: DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 17: Parameters

    Parameters Parameter types Definition You define and thereby influence the functions supported by the module operation of the I/O module via the parameter types. Module/channel parameters Definition Module/channel parameters are specific parameters whose configuration can affect the entire module or channel. Description The following module/channel parameters are available: Parameters...
  • Page 18: Explanation Of The Module/Channel Parameters

    Parameters 5.3 Explanation of the module/channel parameters Parameters Value range Default Parameter re‐ Efficiency range assignment in Potential group (Page 19) Use potential Module • Potential group of the left mod‐ group of the left ule (dark gray terminal block) module •...
  • Page 19: Channel Activated

    Parameters 5.3 Explanation of the module/channel parameters 5.3.4 Channel activated Definition Specifies whether a channel is activated or deactivated. 5.3.5 Hardware interrupts positive edge Definition Specifies if a hardware interrupt should be generated for a rising edge. 5.3.6 Hardware interrupts negative edge Definition Specifies if a hardware interrupt should be generated for a negative edge.
  • Page 20: Double-Width Terminal Block

    Parameters 5.3 Explanation of the module/channel parameters 5.3.8 Double-width terminal block Definition Select the "Double-width terminal block" parameter in the hardware properties for the I/O module. DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 21: Displays And Interrupts

    Displays and interrupts Status and error displays of the I/O module DI 32x24VDC HA Definition The LED displays are status and fault indicators. Diagnostic messages and maintenance events, as well as their possible causes and solutions, are described in the diagnostic messages and maintenance events. Diagnostic messages (Page 32).
  • Page 22: Leds

    Displays and interrupts 6.2 LEDs LEDs 6.2.1 DIAG LED Definition The DIAG LED provides you diagnostic information. Description The diagnostic display of the DIAG LED is as follows: DIAG LED Meaning The power supply of the ET 200SP HA is disrupted or switched off. Module is not configured.
  • Page 23: Channel Status Led

    Displays and interrupts 6.3 Interrupts 6.2.3 Channel status LED Definition Regardless of the parameter assignment, the channel status LED status shows the signal level at the input terminal. It lights up starting at approximately 10 V of terminal voltage. Description The channel status LED indicates the following statuses: LED channel Meaning...
  • Page 24 Displays and interrupts 6.3 Interrupts Description The I/O module generates a diagnostics interrupt at the following events: • Supply voltage L+ missing • Parameter assignment error • Hardware interrupt lost • Channel/component temporarily unavailable • Wire break • Retentive memory in carrier module defective •...
  • Page 25: Technical Specifications

    Technical specifications Technical specifications of the DI 32×24VDC HA Article number 6DL1131-6BL00-0PH1 General information Product type designation DI 32x24VDC HA Firmware version V1.0 • FW update possible Usable terminal block TB type H1 and P0 Color code for module-specific color identifica‐ CC00 tion plate Product function...
  • Page 26 Technical specifications Article number 6DL1131-6BL00-0PH1 Automatic encoding • Mechanical coding element Digital inputs Digital inputs, parameterizable Source/sink input Yes; P-reading Input characteristic curve in accordance with IEC 61131, type 1 Input characteristic curve in accordance with IEC 61131, type 2 Input characteristic curve in accordance with IEC 61131, type 3 Pulse extension...
  • Page 27 Technical specifications Article number 6DL1131-6BL00-0PH1 Potential separation channels • between the channels • between the channels and backplane bus • between the channels and the power supply of the electronics Isolation Isolation tested with 1 500 V DC/1 min, type test Ambient conditions Ambient temperature during operation -40 °C...
  • Page 28 Technical specifications DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 29: Drivers, Parameters, Diagnostics Messages And Address Space

    Drivers, parameters, diagnostics messages and address space Parameter assignment Parameter assignment in the user program You can reconfigure individual channels of the module in RUN without this having an effect on the other channels. Changing parameters in RUN The parameters are transferred to the module with the "WRREC" instruction via data record 128. Output parameter STATUS of the WRREC If errors occur when transferring parameters with the "WRREC"...
  • Page 30: Parameter Assignment And Structure Of The Module/Channel Parameters

    Drivers, parameters, diagnostics messages and address space A.2 Parameter assignment and structure of the module/channel parameters Parameter assignment and structure of the module/channel parameters Structure of data record 128 Data record 128 has a length of 76 bytes. It contains module parameters as well as channel or technology parameters of the 32 channels; 2 bytes each.
  • Page 31 Drivers, parameters, diagnostics messages and address space A.2 Parameter assignment and structure of the module/channel parameters Header information and module parameters The following figure shows the configuration of the header information and module parameters. Channel parameters Every channel parameter block contains the channel parameters for the digital input (2 bytes). The following figure shows the configuration of the channel parameters for channels 0 to 31.
  • Page 32: Diagnostic Messages

    Drivers, parameters, diagnostics messages and address space A.3 Diagnostic messages x = 12 + (channel number * 2); with channel number = 0…31 All unused bits and the bits or bytes marked as "reserved" must be set to zero. You activate a channel parameter by setting the corresponding bit to "1" or the corresponding value.
  • Page 33: Maintenance Events

    Drivers, parameters, diagnostics messages and address space A.4 Maintenance events Diagnostics mes‐ Error code Assign‐ Meaning Remedy sage ment Parameter assign‐ Module • Parameter assignment does not • Correct the parameter assign‐ ment error match the terminal block used ment •...
  • Page 34: Hardware Interrupts

    Drivers, parameters, diagnostics messages and address space A.6 Address space Hardware interrupts Hardware interrupts The DI 32x24VDC HA generates a hardware interrupt for the following events: • At a rising edge (signal change from 0 to 1) • At a falling edge (signal change from 1 to 0) Interrupt OBs are called automatically if an interrupt occurs.
  • Page 35: Table

    Drivers, parameters, diagnostics messages and address space A.6 Address space Address space The following figure shows the allocation of the address space of the DI 32x24VDC HA. Table A-1 Address space of the DI 32x24VDC HA IB x + DI15 DI14 DI13 DI12...
  • Page 36 Drivers, parameters, diagnostics messages and address space A.6 Address space DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 37: Index

    Index Value status Evaluating, 35 DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...
  • Page 38 Index DI 32x24VDC HA Equipment Manual, 10/2021, A5E48262828-AB...