Summary of Contents for OdorStop OS36PRO

  • Page 1 ATTENTION! This System has an airflow sensor and must be installed in the HVAC system in an area that has sufficient airflow to activate the sensor. Please contact our customer care department with any questions. service@odorstop.com 1 (888) 956-7468...
  • Page 2 OS36PRO | OS72PRO | OS144PRO UV Air Treatment System OdorStop, LLC Purchase Date: ____________________________________________ 5139 Southwestern Blvd, Serial Number: _____________________________________________ Hamburg, NY 14075 USA Phone: 1 (888) 956-7468 Purchased From: __________________________________________ Fax: 1 (716) 648-6406 www.OdorStop.com © Copyright 2020. OdorStop, LLC...
  • Page 3 READ INSTRUCTIONS COMPLETELY BEFORE INSTALLATION Congratulations, you have purchased a state-of-the-art UV air treatment system. It is designed to offer years of trouble-free service and sanitize the air to produce the cleanest, freshest air possible. WARNINGS UV LIGHTS CAN BE HARMFUL TO BARE SKIN AND EYES AND CAN CAUSE TEMPORARY OR PERMANENT LOSS OF VISION.
  • Page 4: Installation

    INSTALLATION Included: How To Install Your OdorStop UV Air Treatment System • UV System • 8 Sheet Metal Mounting Screws If your heating/cooling (HVAC) system is equipped with air • UV Bulb(s)-1 for OS36, conditioning, it is recommended that the UV Air Treatment System (unit) be mounted directly above the cooling coil.
  • Page 5 CAUTION: BE SURE TO WEAR APPROPRIATE PROTECTION (I.E. HAND, EAR, EYE, AND FACE PROTECTION) AS CUTTING METAL IS LOUD AND PIECES MAY BE SHARP AND HOT 1. Turn the power to the HVAC system off before installing the system. 2. Select the correct template and tape it to the duct work in the intended installation position.
  • Page 6 5. Take care to prevent the metal disc from falling into the HVAC system. NOTE: If the disc falls into the HVAC system it will not negatively affect its operation. 6. Use tin snips to cut out the metal ducting between the drilled holes along dotted lines as shown in step 5.
  • Page 7 9. Attach the system to duct work with the 8 sheet metal screws using a ¼” nut driver. Make sure to tighten screws evenly. CAUTION: DO NOT OVERTIGHTEN SCREWS. 10. Plug the system into a grounded 120V power outlet. Do not use an extension cord. 11.
  • Page 8 Make sure bulb is clean and dry before installing system back into duct. 3b. To Replace: Visit www.OdorStop.com to purchase new UV bulbs if needed. Use of any bulb not approved for system by OdorStop will void the warranty and could cause damage to system or serious injury.
  • Page 9: Service And Warranty

    OdorStop warrants to the original purchaser that this purifier is free from any defect in materials and workmanship for two (2) years from the date of purchase. OdorStop will replace or repair the system without charge to the customer. This warranty does not include UV bulb(s). To obtain warranty service, please return the system in a...
  • Page 10 STEP 2 - DRILL HOLES WITH 2 1/2” HOLE SAW STEP 3 - SNIP METAL ALONG DASHED LINES CAUTION: BE SURE TO WEAR APPROPRIATE PROTECTION (I.E. HAND, EAR, EYE, AND FACE PROTECTION) AS CUTTING METAL IS LOUD AND PIECES MAY BE SHARP AND HOT. © Copyright 2019, OdorStop, LLC...
  • Page 11 STEP 2 - DRILL HOLES WITH 2 1/2” HOLE SAW STEP 3 - SNIP METAL ALONG DASHED LINES CAUTION: BE SURE TO WEAR APPROPRIATE PROTECTION (I.E. HAND, EAR, EYE, AND FACE PROTECTION) AS CUTTING METAL IS LOUD AND PIECES MAY BE SHARP AND HOT. © Copyright 2019, OdorStop, LLC...
  • Page 12 STEP 2 - DRILL HOLES WITH 2 1/2” HOLE SAW STEP 3 - SNIP METAL ALONG DASHED LINES CAUTION: BE SURE TO WEAR APPROPRIATE PROTECTION (I.E. HAND, EAR, EYE, AND FACE PROTECTION) AS CUTTING METAL IS LOUD AND PIECES MAY BE SHARP AND HOT. © Copyright 2019, OdorStop, LLC...