Page 2
Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RST916P Communication Ports Technical Specifications Installation Manual Certification 04/2021 C79000-G8976-1489-01...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
Contacting Siemens • Submit SRs or check on the status of an existing SR • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community...
Introduction The RUGGEDCOM RST916P is a 16-port utility-grade, fully managed Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding environments. • Removable SFP Transceivers The device supports up to four Small Form-factor Portable (SFP) transceivers, allowing the device to be adapted to the requirements of the network application.
Introduction 1.1 Feature Highlights Feature Highlights Ethernet Ports • 4 x sockets for SFP/SFP+ transceivers • 2 x 10/100/1000Base-T copper Ethernet ports • 10 x 10/100/1000Base-T RJ45 802.3af//802.3at/802.3bt compliant Power-over- Ethernet (PoE) ports • Data and power over a single PoE cable •...
Page 12
Introduction 1.2 Description POWER LED ALARM LED USB Console Port CLP Port SFP Tranceiver Sockets (Ports 11 to 14) Copper Ethernet Ports (Ports 15 and 16) Failsafe Alarm Relay Copper PoE Ports (Ports 1 to 10) Power Supply Terminal Block Chassis Ground Screw Figure 1.1 RUGGEDCOM RST916P POWER LED...
Introduction 1.3 Required Tools and Materials • "Connecting the Failsafe Alarm Relay (Page 12)" • "Failsafe Alarm Relay Specifications (Page 27)" Power Supply Terminal Blocks Pluggable terminal blocks for connecting one or more power sources. For more information, refer to "Connecting Power (Page 14)"...
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Inspect the package for damage before opening it. Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. RUGGEDCOM RST916P Installation Manual, 04/2021, C79000-G8976-1489-01...
Installing the Device 2.3 Installing the Device in Hazardous Locations Installing the Device in Hazardous Locations The RUGGEDCOM RST916P is designed to comply with the safety standards for Class I, Division 2, Zone 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
Installing the Device 2.4 Mounting the Device Sample Hazardous Location Label The following is an example of the RUGGEDCOM RST916P hazardous location label: II 3 G Figure 2.1 Compliance Label (Example) Mounting the Device The RUGGEDCOM RST916P is designed for maximum mounting and display flexibility.
Page 18
Installing the Device 2.4.1 Mounting the Device on a DIN Rail Mounting the Device To mount the device to a DIN rail, do the following: Hook the top teeth of the adapter onto the DIN rail. Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver.
Installing the Device 2.4.2 Mounting the Device to a Panel Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.3 Removing the Device from a DIN Rail...
Page 20
Installing the Device 2.4.2 Mounting the Device to a Panel Rear-Mount Orientation Side-Mount Orientation Figure 2.4 Panel Mount Options To mount the device to a panel, do the following: Secure the mounting adapters to the top and bottom of the device in the desired orientation using the eight M4 screws included with the device.
Installing the Device 2.5 Connecting the Failsafe Alarm Relay Place the device against the panel and align the adapters with the mounting holes. Screw (M5 or #10-24) Panel Mount Adapter Figure 2.6 Panel Mounting (Rear Mount Orientation) Secure the adapters to the panel with screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
Page 22
Installing the Device 2.5 Connecting the Failsafe Alarm Relay To connect the failsafe alarm relay, do the following: Insert the failsafe alarm relay terminal block into the device and tighten the screws. Figure 2.7 Assembling the Failsafe Alarm Relay Terminal Block Connect a failsafe device to the terminal block. Failsafe Alarm Relay Terminal Block Normally Open Common...
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to https:// support.industry.siemens.com/cs/ww/en/view/109478699.
Page 24
Installing the Device 2.6.2 Connecting DC Power provides reverse polarity protection and accepts secondary connections (+/-) from the same power supply (if available). To connect an external DC power source to the device, do the following: Note For examples of the supported wiring configurations, refer to "Wiring Examples (Page 16)".
Installing the Device 2.6.3 Wiring Examples Connect the Positive wire from the power supply to either of the positive (+) terminals on the terminal block. Connect the Negative wire from the power supply to either of the negative (-) terminals on the terminal block. Connect the ground wire from the power supply to the chassis/ground terminal on the terminal block.
Page 26
Installing the Device 2.6.3 Wiring Examples Figure 2.11 Single DC Power Input Figure 2.12 Dual DC Power Input Configuration Configuration Figure 2.13 Single DC Power Input Figure 2.14 Dual DC Power Input Configuration with Dual Configuration with Dual Positive/Negative Inputs Positive/Negative Inputs RUGGEDCOM RST916P Installation Manual, 04/2021, C79000-G8976-1489-01...
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RST916P console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RST916P.
Device Management 3.2 Configuring the Device Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RST916P console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RST916P is https://192.168.0.1.
Page 30
Device Management 3.3 Inserting/Removing the CLP Removing the CLP To remove the CLP, do the following: NOTICE Configuration hazard – risk of data loss After uploading or downloading a file, allow at least twenty seconds before removing the CLP to ensure the data has been fully transferred. Remove the CLP (or blank insert) from the CLP port.
Page 31
Device Management 3.3 Inserting/Removing the CLP Inserting the CLP To insert the CLP, do the following: Remove the current CLP (or blank insert) from the device. Blank Insert Figure 3.2 Inserting the CLP Insert the CLP into the CLP port. RUGGEDCOM RST916P Installation Manual, 04/2021, C79000-G8976-1489-01...
Communication Ports The RUGGEDCOM RST916P can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 to 10 Ports 11 to 14 Ports 15 to 16 Figure 4.1 Port Assignment Port Type 1 to 10 Copper (10/100/1000Base-T) Power-over-Ethernet (PoE) Ports 11 to 14 SFP/SFP+ Transceivers...
Communication Ports 4.1 Copper Ethernet Ports Copper Ethernet Ports The device supports multiple 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5E (CAT-5E) or higher shielded twisted-pair cables with RJ45 male connectors. WARNING Electric shock hazard – risk of serious personal injury and/or equipment interference When shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end.
For specifications on the available PoE ports, refer to "PoE Output Specifications (Page 27)". SFP Transceivers The RUGGEDCOM RST916P supports up to four Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. RUGGEDCOM RST916P Installation Manual, 04/2021, C79000-G8976-1489-01...
Page 35
RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. Note Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. RUGGEDCOM RST916P...
Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the power supply is provided at the power source. Power Minimum Maximum Fuse Rating Isolation Maximum Maximum...
Technical Specifications 5.4 Supported Networking Standards Maximum Switching Voltage Rated Isolation Switching Current 1.0 kVAC between contacts 50 to 60 Hz for 1 minute Non-Hazardous Environment Maximum Switching Voltage Rated Isolation Switching Current 30 VDC 5.0 kVAC between coil and contacts 1.0 kVAC between contacts 250 VAC...
Technical Specifications 5.5 Copper Ethernet Port Specifications Standard 10 Mbps 1000 10000 Description Mbps Mbps Mbps IEEE 1588-2008 • • • • Precision Time Control (PTP) Version 2 IEC 62439-2:2016 • • • • Media Redundancy Protocol (MRP) Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RST916P.
Certification The RUGGEDCOM RST916P device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RST916P complies. 6.1.1 This device meets the requirements of the following Canadian and U.S. standards under certificate CSA 21CA80047239: •...
Certification 6.1.2 CSANe • ANSI/UL 60079-15:20 Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Type of Protection "n" • ANSI/UL 60079-7:2017 Explosive atmospheres – Part 7: Equipment protection by increased safety ’’e’’ The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S.
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A)
Republic of Korea (South Korea) as a Class A product in a commercial, industrial or business environment. R-R-S14-RST916P A copy of the KC Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
Certification 6.1.9 RoHS 6.1.9 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
Page 47
Certification 6.2 EMC and Environmental Type Tests EMC Type Tests Test Description Test Levels Severity Levels Enclosure ± 8 kV 61000-4-2 Contact Enclosure Air ± 15 kV Radiated RFI Enclosure 20 V/m 61000-4-3 Ports Burst (Fast Transient) Signal Ports ± 4 kV @ 2.5 kHz, 5 kHz 61000-4-4 DC Power ±...
Page 48
Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels 100% for 0.05 s Dielectric Strength Signal Ports 2 kV (Failsafe Relay Output) 60255-27 DC Power 2 kV or 2.8kV DC Ports AC Power 2 kV ...
Page 49
Certification 6.2 EMC and Environmental Type Tests Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40 °F), 16 Hours Cold Storage Test Ab -40 °C (-40 °F), 16 Hours IEC 60068-2-2 Dry Heat Test Bd 85 °C (185...
Page 50
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...