CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) Preface ET 200SP Documentation Guide SIMATIC Product overview Wiring ET 200SP CPU 1510SP-1 PN Interrupts, error messages, (6ES7510-1DJ01-0AB0) diagnostics and system alarms Equipment Manual Technical specifications Dimension drawing 05/2021 A5E03506268-AD...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Page 5
This information is provided by the Siemens Industry Online Support in the Internet (http://www.siemens.com/automation/service&support). Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
Table of contents Preface ..............................3 ET 200SP Documentation Guide ......................6 Product overview ..........................11 New functions ........................11 Operating principle ......................13 Properties .......................... 14 Operating and display elements ..................19 2.4.1 Front view of the module with BusAdapter ................. 19 Mode switch ........................
ET 200SP Documentation Guide The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require. Basic information The System Manual and Getting Started describe in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200SP distributed I/O system.
Page 8
You must register once to use the full functionality of "mySupport". You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en). "mySupport" - Documentation With "mySupport", your personal workspace, you make the best out of your Industry Online Support.
Page 9
• Manuals, characteristics, operating manuals, certificates • Product master data You can find "mySupport" - CAx data on the Internet (https://support.industry.siemens.com/my/ww/en/CAxOnline). Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
Page 10
You can find the SIMATIC Automation Tool on the Internet (https://support.industry.siemens.com/cs/ww/en/view/98161300). PRONETA SIEMENS PRONETA (PROFINET network analysis) allows you to analyze the plant network during commissioning. PRONETA features two core functions: • The topology overview automatically scans the PROFINET and all connected components.
Page 11
ET 200SP Documentation Guide SINETPLAN SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and networks based on PROFINET. The tool facilitates professional and predictive dimensioning of your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports you during network optimization and helps you to exploit network resources optimally and to plan reserves.
PLC tion manual 200 CPUs from firmware version 2.9 communication certificates (https://support.industr support innovated and standardized y.siemens.com/cs/ww/ secure PG/PC and HMI communica- en/view/59192925) tion – referred to as Secure PG/HMI communication for short. Protection of confidential...
Page 13
CPU into an existing IT tion manual configuration via a DHCP server. network without having to (https://support.industr make additional changes to y.siemens.com/cs/ww/ The CPU uses a client ID for identifi- the PROFINET interface. en/view/59192925) cation on the DHCP server. The following parameters can be obtained: •...
Reference You can find an overview of all new functions, improvements and revisions in the respective firmware versions on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109478459). Operating principle The CPU contains the operating system and executes the user program. The user program is located on the SIMATIC memory card and is processed in the work memory of the CPU.
Product overview 2.3 Properties Intelligent DP slave (I-slave) To use the ET 200SP as an intelligent DP slave (I-slave), you need the CPU and the optional communication module, CM DP. As an I-slave, the ET 200SP CPU is connected via PROFIBUS DP to a higher-level DP master and exchanges data with it.
Page 16
The CM DP is optionally available with a PROFIBUS interface (X2). You can find additional information about this expansion module in the manual Communication module CM DP (http://support.automation.siemens.com/WW/view/en/90156526). You can find information about connecting the PROFINET IO BusAdapter to the CPU as...
Page 17
You can find a detailed description of the use of Motion Control and its configuration in the S7-1500 Motion Control (https://support.industry.siemens.com/cs/ww/en/view/109751049) function manuals. – Integrated closed-loop control functionality - PID Compact (continuous PID controller) - PID 3Step (step controller for integrating actuators)
Page 18
You can find additional information on the topic of "Protection" in the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). • Support for ET 200AL – Simple connection of IP 65/67 I/O modules to the CPU.
Page 19
• CPU 1510SP-1 PN supports the following additional functions: – PROFIenergy You can find information on the topic of "PROFIenergy" in the PROFINET function manual (https://support.industry.siemens.com/cs/ww/en/view/49948856) and in the PROFINET specification on the Internet (http://www.profibus.com). – Shared device You can find information on the topic of "Shared device" in the PROFINET function manual (https://support.industry.siemens.com/cs/ww/en/view/49948856).
Product overview 2.4 Operating and display elements Operating and display elements 2.4.1 Front view of the module with BusAdapter The figure on the left shows the CPU 1510SP-1 PN including a plugged BA 2xRJ45 BusAdapter. The figure on the right shows a separate view of the BA 2xRJ45 BusAdapter. ①...
Product overview 2.5 Mode switch Mode switch Use the mode switch to set the CPU operating mode. The following table shows the position of the switch and the corresponding meaning. Table 2- 1 Mode switch settings Position Meaning Explanation RUN mode The CPU is executing the user program.
Wiring This section provides information on the pin assignment of the individual interfaces and the block diagram of the CPU 1510SP-1 PN. 24 V DC supply voltage (X80) The connector for the supply voltage is plugged in when the CPU ships from the factory. The following table shows the signal names and the descriptions of the pin assignment of the 24 V DC supply voltage.
Page 23
Receive data + RD_N Receive data - Reference You can find additional information on the topics of "Connecting the CPU" and "Accessories/spare parts" in the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) Equipment Manual, 05/2021, A5E03506268-AD...
Page 24
Wiring Assignment of the MAC addresses The MAC address is a globally unique device identifier that is assigned to each PROFINET device in the factory. Its 6 bytes are divided into 3 bytes for the manufacturer ID and 3 bytes for the device ID (serial number).
Page 25
Wiring Block diagram The following figure shows the block diagram of the CPU 1510SP-1 PN. ① PROFINET switch P1 R PROFINET interface X1 Port 1 ② Electronics P2 R PROFINET interface X1 Port 2 ③ Backplane bus interface PROFINET interface X1 Port 3 ④...
The status and error displays of the CPU 1510SP-1 PN are described below. You will find additional information on "Interrupts" in the STEP 7 online help. You can find additional information on the topics of "Diagnostics" and "System alarms" in the Diagnostics (http://support.automation.siemens.com/WW/view/en/59192926) function manual. Status and error display of the CPU...
Page 27
Interrupts, error messages, diagnostics and system alarms 4.1 Status and error display of the CPU Meaning of the POWER, RUN/STOP, ERROR and MAINT LEDs CPU 1510SP-1 PN features an LED for monitoring the supply voltage of the electronics (PWR) and three LEDs for displaying the current operating and diagnostics status. The following table shows the meaning of the various combinations of colors for the POWER, RUN/STOP, ERROR and MAINT LEDs.
Page 28
Interrupts, error messages, diagnostics and system alarms 4.1 Status and error display of the CPU POWER RUN/STOP LED ERROR MAINT Meaning LED lit green LED flashes LED flashes red LED flashes yellow Test of LEDs during startup, inserting a yellow/green module.
Technical specifications The following table shows the technical specifications as of 05/2021. You will find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7510-1DJ01-0AB0/td?dl=en). Article number 6ES7510-1DJ01-0AB0 General information Product type designation CPU 1510SP-1 PN HW functional status...
Page 30
Technical specifications Article number 6ES7510-1DJ01-0AB0 Work memory 100 kbyte • integrated (for program) 750 kbyte • integrated (for data) Load memory 32 Gbyte • Plug-in (SIMATIC Memory Card), max. Backup • maintenance-free CPU processing times for bit operations, typ. 72 ns for word operations, typ.
Page 31
Technical specifications Article number 6ES7510-1DJ01-0AB0 • Number of diagnostic alarm OBs Nesting depth • per priority class Counters, timers and their retentivity S7 counter 2 048 • Number Retentivity adjustable – IEC counter Any (only limited by the main memory) •...
Page 32
Technical specifications Article number 6ES7510-1DJ01-0AB0 per CM/CP 8 kbyte Inputs (volume) – 8 kbyte Outputs (volume) – Subprocess images • Number of subprocess images, max. Address space per module 288 byte; For input and output data respectively • Address space per module, max. Address space per station 2 560 byte;...
Page 33
Technical specifications Article number 6ES7510-1DJ01-0AB0 Clock synchronization • supported Yes; Via CM DP module • to DP, master Yes; Via CM DP module • to DP, slave • in AS, master • in AS, slave • on Ethernet via NTP Interfaces Number of PROFINET interfaces Number of PROFIBUS interfaces...
Page 34
Technical specifications Article number 6ES7510-1DJ01-0AB0 Number of connectable IO Devices for – RT, max. of which in line, max. – 8; in total across all interfaces Number of IO Devices that can be simul- – taneously activated/deactivated, max. Number of IO Devices per tool, max. –...
Page 35
Technical specifications Article number 6ES7510-1DJ01-0AB0 2. Interface Interface types Yes; Via CM DP module • RS 485 • Number of ports Protocols • PROFIBUS DP master • PROFIBUS DP slave • SIMATIC communication PROFIBUS DP master 48; Of which 4 each reserved for ES and HMI •...
Page 36
Technical specifications Article number 6ES7510-1DJ01-0AB0 Redundancy mode • H-Sync forwarding Media redundancy Yes; only via BusAdapter Media redundancy – – Yes; as MRP ring node according to IEC 62439-2 MRP interconnection, supported – Edition 3.0 Yes; Requirement: IRT MRPD – 200 ms;...
Page 37
Technical specifications Article number 6ES7510-1DJ01-0AB0 OPC UA Yes; "Small" license required • Runtime license required • OPC UA Client Application authentication – Available security policies: None, Basic128Rsa15, Security policies – Basic256Rsa15, Basic256Sha256 "anonymous" or by user name & password User authentication –...
Page 38
Technical specifications Article number 6ES7510-1DJ01-0AB0 500 ms Publishing interval, min. – Number of server methods, max. – Number of inputs/outputs per server – method, max. 1 000; for 1 s sampling interval and 1 s send in- Number of monitored items, max. –...
Page 39
Technical specifications Article number 6ES7510-1DJ01-0AB0 Diagnostic buffer • present 1 000 • Number of entries, max. of which powerfail-proof – Traces 4; Up to 512 KB of data per trace are possible • Number of configurable Traces Interrupts/diagnostics/status information Diagnostics indication LED •...
Page 40
Technical specifications Article number 6ES7510-1DJ01-0AB0 Standards, approvals, certificates Highest safety class achievable in safety mode none • Performance level according to ISO 13849- • SIL acc. to IEC 61508 Ambient conditions Ambient temperature during operation -25 °C; No condensation • horizontal installation, min.
Page 41
Technical specifications Article number 6ES7510-1DJ01-0AB0 Weights Weight, approx. 310 g Technical specifications of the BusAdapter BA 2×RJ45 Article number 6ES7193-6AR00-0AA0 General information Product type designation BA 2x RJ45 Interfaces Number of PROFINET interfaces Supports protocol for PROFINET IO • Number of RJ45 ports •...
Page 42
General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc., in the system manual ET 200SP distributed I/O system (http://support.automation.siemens.com/WW/view/en/58649293). CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) Equipment Manual, 05/2021, A5E03506268-AD...
Dimension drawing This section contains a dimension drawing of the module mounted on a mounting rail. Always observe the specified dimensions for installation in cabinets, control rooms, etc. Dimension drawing of the CPU 1510SP-1 PN Figure A-1 Dimensional drawing CPU 1510SP-1 PN CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) Equipment Manual, 05/2021, A5E03506268-AD...