hit counter script
Download Print this page
Sony ECM-Z60 Service Manual
Sony ECM-Z60 Service Manual

Sony ECM-Z60 Service Manual

Electret condenser microphone

Advertisement

Quick Links

SERVICE MANUAL
Ver 1.0 2000.2
SPECIFICATIONS
Type
Electret condenser microphone
Dimensions
Microphone parts:
16 × 106 × 22 mm (
× 4
×
21
/
1
/
7
/
in.)(diameter/
32
4
8
length/height)
(Maximum width of stand: 26 mm (1
1
/
in.))
16
Battery box parts:
40 × 16.5 × 46 mm (w/h/d)
× 2
× 1
5
1
13
(1
/
/
/
in.)
8
32
16
Mass
Microphone parts (including cord):
Approx. 21 g (0.75 oz.)
Battery box parts (including lithium battery and
cord):
Approx. 17 g (0.6 oz.)
Cord
Microphone parts:
OFC litz cord (1 cord shielded)
1
1.5 mm (
/
in.) dia.
16
Length: approx. 1 m (39
3
/
in.)
8
Battery box parts:
OFC litz cord (2 core shielded)
2.2 mm (
3
/
in.) dia.
32
7
Length: approx. 0.3 m (11
/
in.)
8
Supplied accessories
Battery box (1)
ECM-Z60
US Model
Canadian Model
AEP Model
Frequency response
100 -10,000 Hz
Directivity
Super-directional
Output impedance
2.8 kΩ ± 30 %
Sensitivity
Open circuit output voltage
level –36 ± 3.5 dB
0 dB = 1 V / Pa, 1,000 Hz
(1 Pa = 10 µ bar = 94 dB
)
SPL
Battery life
Approx. 300 hours (with Sony CR2025 lithium
battery (not supplied)
Maximum sound pressure input level
Approx. 102 dB
SPL
1 % wave distortion at 1,000 Hz
= 2 × 10
-5
(0 dB
Pa)
SPL
Operating temprerature range
0 °C –40 °C (32 °F –104 °F)
Design and specifications are subject to change without notice.
ELECTRET CONDENSER MICROPHONE
E Model
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be
damaged by heat.
Flexible Circuit Board Repairing
• Keep the temperature of soldering iron around 270˚C
during repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
SECTION 1
This section is extracted from
instruction manual.
GENERAL
1 POWER switch
2 Battery check indicator
3 L-shaped monaural miniplug (gold plated)
4 Battery box
5 Microphone jack
6 L-shaped monaural miniplug (gold plated)
7 Battery compartment
8 Microphone
9 Attached microphone stand
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by
the manufacturer.
Discard used batteries according to the manufacturer's instructions.
ADVARSEL!
Lithiumbatteri-Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandøren.
ADVARSEL
Eksplosjonsfare ved feilaktig skifte av batteri.
Benytt samme batteritype eller en tilsvarende type
anbefalt av apparatfabrikanten.
Brukte batterier kasseres i henhold til fabrikantens
instruksjoner.
VARNING
Explosionsfara vid felaktigt batteribyte.
Använd samma batterityp eller en likvärdig typ som
rekommenderas av apparattillverkaren.
Kassera använt batteri enligt gällande föreskrifter.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin.
Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.
— 2 —

Advertisement

loading

Summary of Contents for Sony ECM-Z60

  • Page 1 (1 Pa = 10 µ bar = 94 dB Mass Microphone parts (including cord): Approx. 21 g (0.75 oz.) Battery life Approx. 300 hours (with Sony CR2025 lithium Battery box parts (including lithium battery and battery (not supplied) cord): Maximum sound pressure input level CAUTION Approx.
  • Page 2 ECM-Z60 SECTION 2 DIAGRAMS 2-1. SCHEMATIC DIAGRAM 2-2. PRINTED WIRING BOARD MIC UNIT UNIT BOARD UNIT BOARD MIC1 (SIDE A) (SIDE B) UDZ4.7B 1-671-999- (11) (11) 1-671-999- MINI (MIC OUT) PLUG MIC IN AMP BOARD AMP BOARD (SIDE A) (SIDE B) TOTAL CURRENT : 0.21mA...
  • Page 3 SECTION 3 EXPLODED VIEWS NOTE: 3-2. MICROPHONE SECTION • -XX, -X mean standardized parts, so they may • The mechanical parts with no reference number have some differences from the original one. in the exploded views are not supplied. • Items marked “*”...
  • Page 4 ECM-Z60 SECTION 4 UNIT ELECTRICAL PARTS LIST NOTE: • Due to standardization, replacements in the • CAPACITORS: • SEMICONDUCTORS parts list may be different from the parts uF: µF In each case, u: µ, for example: specified in the diagrams or the components •...