SIMATIC
HMI devices
Comfort Panels INOX, ITC INOX
Compact Operating Instructions
09/2017
A5E33472156-AI
___________________
Preface
___________________
Overview
___________________
Safety instructions
___________________
Installing and connecting the
device
___________________
Cleaning the device
___________________
Technical specifications
___________________
Technical Support
___________________
List of abbreviations
1
2
3
4
5
A
B

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC INOX Series

  • Page 1 ___________________ Preface ___________________ Overview ___________________ SIMATIC Safety instructions ___________________ Installing and connecting the device HMI devices Comfort Panels INOX, ITC INOX ___________________ Cleaning the device ___________________ Technical specifications Compact Operating Instructions ___________________ Technical Support ___________________ List of abbreviations 09/2017 A5E33472156-AI...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    The notes in these compact operating instructions take precedence over statements in the basic operating instructions, the release notes and online help. Comfort Panels operating instructions (http://support.automation.siemens.com/WW/view/en/49313233) Industrial Thin Clients operating instructions (http://support.automation.siemens.com/WW/view/en/61187980) Unless otherwise described in this document, all of the statements made in the general operating manual concerning the basic device are valid for the corresponding INOX device.
  • Page 4 Preface Style conventions Style Convention Scope "Add screen" Terms that occur in the user interface, for example, dialog name, tab, • button, menu command Necessary entries, for example, limit value, tag value • Path specification • "File > Edit" Operating sequences, for example, menu item, shortcut menu command <F1>, <Alt+P>...
  • Page 5: Table Of Contents

    Table of contents Preface ............................3 Overview ............................7 Product overview ......................... 7 Scope of delivery ......................... 8 Layout of the devices......................8 Interfaces ..........................9 Accessories ........................10 Safety instructions ........................11 General safety instructions ....................11 Notes on use ........................12 Supplemental notes ......................
  • Page 6 Table of contents Technical specifications ....................... 26 Certificates and approvals ....................26 Dimension drawings ......................30 5.2.1 Dimension drawing TP700 Comfort INOX ................30 5.2.2 Dimension drawing TP900 Comfort INOX ................31 5.2.3 Dimension drawing TP1200 Comfort INOX .................32 5.2.4 Dimension drawing TP1500 Comfort INOX .................33 5.2.5 Dimension drawing TP1900 Comfort INOX, ITC1900 INOX ..........34 Technical specifications ......................35...
  • Page 7: Overview

    Overview Product overview INOX devices with touch screen and stainless steel front are designed for use in the food and beverage industry, including in splash zones of food production, the pharmaceutical industry, fine chemicals and in other hygiene areas for machine-level operator control and monitoring.
  • Page 8: Scope Of Delivery

    Overview 1.2 Scope of delivery Scope of delivery Depending on the order, the scope of delivery includes: ● 1 × device ● 1 × accessory pack with the following contents: – 1 mounting gasket – 1 clamping frame – 1 power supply terminal –...
  • Page 9: Interfaces

    Overview 1.4 Interfaces Bottom view ① Ports ② Cutout for mounting clip Interfaces Interfaces of the Comfort INOX devices TP700 Comfort INOX, TP900 Comfort INOX, TP1200 Comfort INOX ① ⑤ X80 power supply connector X1 PROFINET (LAN), 10/100 Mb ② ⑥...
  • Page 10: Accessories

    USB ports Accessories Accessories can be ordered on the Internet at: Industry Mall (https://mall.industry.siemens.com) The following service packs with clamping frames, mounting gaskets, mounting clips and strain relief plate are available for the INOX devices: ● TP700 INOX Service Pack, article number 6AV2185-4GA00-0AX0 ●...
  • Page 11: Safety Instructions

    Safety instructions General safety instructions Installation according to the instructions WARNING The device may only be used in machines which comply with the Machinery Directive The "Machinery Directive" governs, among other things, the precautions to be taken when commissioning and operating machines within the European Economic Area. Failure to follow these precautions is a breach of the Machinery Directive.
  • Page 12: Notes On Use

    Safety instructions 2.2 Notes on use Electrostatically sensitive components include almost all electrical, electronic, optoelectronic and electromechanical components. These components are sensitive to overvoltage for technical reasons and their function may be impaired or destroyed by electrostatic discharge. Observe the regulations governing the handling of ESD components. Notes on use Note Avoid direct or indirect contact with food in the area of the device's decorative foil to avoid...
  • Page 13: Installing And Connecting The Device

    Damaged parts A damaged part can cause device malfunctions. Do not install damaged parts. In the case of damaged parts or incomplete delivery, contact your Siemens representative. 3.2.2 Checking the operating conditions Note the following aspects before installing the device: 1.
  • Page 14: Selecting A Mounting Position

    Installing and connecting the device 3.2 Preparing for installation 3.2.3 Selecting a mounting position The HMI device is suitable for installation in: ● Mounting cabinets ● Control cabinets ● Switchboards ● Consoles In the following, all of these mounting options are referred to by the general term "cabinet". The HMI device is self-ventilated and approved for inclined mounting at angles of up to +/-35°...
  • Page 15 Installing and connecting the device 3.2 Preparing for installation Mounting position Select one of the approved mounting positions for your HMI device. The approved mounting positions are described in the following sections using the TP700 Comfort INOX as an example. Mounting in horizontal format All HMI devices are suitable for horizontal mounting positions.
  • Page 16: Checking Clearances

    Installing and connecting the device 3.2 Preparing for installation 3.2.4 Checking clearances The following clearances are required around the HMI device to ensure sufficient self- ventilation: ● At least 23 mm to the right and to the left of the mounting cutout (in the x direction) for mounting the clamping frame during installation ●...
  • Page 17: Inserting The Mounting Gasket

    Installing and connecting the device 3.3 Inserting the mounting gasket Inserting the mounting gasket The following process describes the use of the mounting gasket for all devices based on the example of the TP700 Comfort INOX. The mounting gasket is unsymmetrical and is therefore equipped with a coding tap. On all mounting gaskets of the INOX devices, the coding tap is on the bottom left in relation to the rear of the device.
  • Page 18 Installing and connecting the device 3.3 Inserting the mounting gasket 2. Place the mounting gasket as shown on the stainless steel face. ① Seal rounding lies below the housing frame ② Sealing clamp locks fully into the cutout ③ Coding tap 3.
  • Page 19: Positions Of The Mounting Clips For Tp1900 Comfort Inox And Itc1900 Inox

    Installing and connecting the device 3.4 Positions of the mounting clips for TP1900 Comfort INOX and ITC1900 INOX Positions of the mounting clips for TP1900 Comfort INOX and ITC1900 INOX The following section describes how you can install the device. Observe the following mounting clip positions for the TP1900 Comfort INOX and the ITC1900 INOX: Comfort Panels INOX, ITC INOX Compact Operating Instructions, 09/2017, A5E33472156-AI...
  • Page 20: Mounting The Device

    Installing and connecting the device 3.5 Mounting the device Mounting the device The following process describes installation for all devices based on the example of the TP700 Comfort INOX. Requirement ● All packaging components and the edge protection tape, if present, have been removed. ●...
  • Page 21 Installing and connecting the device 3.5 Mounting the device Installation 1. Assemble the device with inserted mounting gasket, clamping frame and all supplied mounting clips as shown in the figure below. Observe the additional product information, if any, supplied with the product. The tip of the setscrew must be inserted into the center hole as shown in the zoomed section of the figure.
  • Page 22: Connecting The Device

    Installing and connecting the device 3.6 Connecting the device Connecting the device The specifications in the relevant operating instructions apply. Please also note the following information. Connection in hazardous areas WARNING Explosion hazard The audio connectors are only designed for temporary connection. Do not use, connect or disconnect until the device is in a non-hazardous area.
  • Page 23: Cleaning The Device

    Cleaning the device Cleaning product The specifications in the operating instructions apply when using the device in hazardous areas of Zones 2 and 22. For use of the device at normal atmospheric conditions, the following is permitted in addition to the operating instructions: ●...
  • Page 24: Chemical Resistance

    ● Ester ● Hydrocarbons ● Household cleaners You can find information of chemical resistance on the Internet (http://support.automation.siemens.com/WW/view/en/39718396). Mounting gasket The mounting gasket made of EPDM is approved for food according to FDA 21 CFR 177-2600. Working with stainless steel surfaces...
  • Page 25 Cleaning the device 4.4 Working with stainless steel surfaces Cleaning guidelines Further information on stainless steel surfaces: ● The surface should be properly ventilated. ● Keep the surface clean. Remove cleaners and food residue immediately. Always avoid the return of food stuff splashes to the production process. ●...
  • Page 26: Technical Specifications

    (RoHS Directive) EU Declaration of Conformity The EU Declarations of Conformity are available to the relevant authorities at the following address: Siemens AG Digital Factory Factory Automation DF FA AS SYS P.O. Box 1963...
  • Page 27 Technical specifications 5.1 Certificates and approvals UL approval Underwriters Laboratories Inc., to ● UL 508 (Industrial Control Equipment) ● CSA C22.2 No. 142 (Process Control Equipment) Underwriters Laboratories Inc., to ● UL 508 (Industrial Control Equipment) ● CSA C22.2 No. 142 (Process Control Equipment) ●...
  • Page 28 A5E02095382) included with your device and is available on the Internet at the following address: ATEX-FAQ (https://support.industry.siemens.com/cs/ww/en/view/291285) Operating temperature for ITC1900 INOX, TP1900 Comfort INOX The ambient temperature range is 0 °C ≤ T ≤ 45 °C. Under these conditions, the HMI device satisfies a maximum surface temperature of xx °C for category 3D...
  • Page 29 Technical specifications 5.1 Certificates and approvals Under the special conditions mentioned, the following approvals apply to the device: ● II 3 G Ex nA IIC T4 Gc and II 3 D Ex tc IIIC T70 ºC Dc IP65 ATEX certificate number: –...
  • Page 30: Dimension Drawings

    Technical specifications 5.2 Dimension drawings Marine approvals The marine approvals for the device are listed in the following product information: Comfort Panels INOX, ITC INOX Marine approvals (https://support.industry.siemens.com/cs/ww/en/ps/14830/man) Dimension drawings 5.2.1 Dimension drawing TP700 Comfort INOX Clamping frame Comfort Panels INOX, ITC INOX...
  • Page 31: Dimension Drawing Tp900 Comfort Inox

    Technical specifications 5.2 Dimension drawings 5.2.2 Dimension drawing TP900 Comfort INOX Clamping frame Comfort Panels INOX, ITC INOX Compact Operating Instructions, 09/2017, A5E33472156-AI...
  • Page 32: Dimension Drawing Tp1200 Comfort Inox

    Technical specifications 5.2 Dimension drawings 5.2.3 Dimension drawing TP1200 Comfort INOX Clamping frame Comfort Panels INOX, ITC INOX Compact Operating Instructions, 09/2017, A5E33472156-AI...
  • Page 33: Dimension Drawing Tp1500 Comfort Inox

    Technical specifications 5.2 Dimension drawings 5.2.4 Dimension drawing TP1500 Comfort INOX Clamping frame Comfort Panels INOX, ITC INOX Compact Operating Instructions, 09/2017, A5E33472156-AI...
  • Page 34: Dimension Drawing Tp1900 Comfort Inox, Itc1900 Inox

    Technical specifications 5.2 Dimension drawings 5.2.5 Dimension drawing TP1900 Comfort INOX, ITC1900 INOX Clamping frame Comfort Panels INOX, ITC INOX Compact Operating Instructions, 09/2017, A5E33472156-AI...
  • Page 35: Technical Specifications

    Technical specifications 5.3 Technical specifications Technical specifications Weight Device Weight including clamping frame, gasket and mounting clips, without packaging TP700 Comfort INOX approx. 1.9 kg TP900 Comfort INOX approx. 2.5 kg TP1200 Comfort INOX approx. 3.6 kg TP1500 Comfort INOX approx.
  • Page 36: Classification Of Environmental Conditions

    Technical specifications 5.4 Classification of environmental conditions Classification of environmental conditions 5.4.1 Overview The standards of the IEC 60721 series can be used to classify short-term extreme environmental conditions that can occur during the service life of a product. Structurally, the product is designed in such a way that it can withstand the extreme environmental conditions according to the classification.
  • Page 37: Classification For Shipping

    Technical specifications 5.4 Classification of environmental conditions 5.4.3 Classification for shipping This device exceeds requirements according to IEC 61131-2:2007 "Programmable controllers – Part 2: Equipment requirements and tests" in terms of valid environmental conditions. The following specifications apply to the device when transported in the original packing. ●...
  • Page 38: Classification For Stationary And Weather-Protected Use

    Technical specifications 5.4 Classification of environmental conditions Tests for mechanical environmental conditions in the transport packaging The following table shows the type and scope of the tests of the device with regard to mechanical environmental conditions. Test Physical variable Value Vibration test Vibration 3 axes, 10 cycles per axis...
  • Page 39 Technical specifications 5.4 Classification of environmental conditions Ambient temperature during operation Type of condition Mounting position Permissible range Temperature, Vertical 0 ... 50 °C Installation in horizontal format inclined, incline max. 35 0 ... 40 °C Temperature, Vertical 0 ... 40 °C Installation in portrait format inclined, incline max.
  • Page 40: Climate Diagram

    Technical specifications 5.4 Classification of environmental conditions Test Physical variable Value Fall Fall height 1.0 m EN 60068-2-31:2009 Number of strains Test Ec Tests for climatic environmental conditions during operation The following table shows the type and scope of the tests of the device with regard to climatic environmental conditions.
  • Page 41: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
  • Page 42: List Of Abbreviations

    List of abbreviations Direct Current Components and modules endangered by electrostatic discharge Electromagnetic Compatibility European standard Food and Drug Administration Ground High Frequency International Electronic Commission Internet Protocol Light Emitting Diode Thin Film Transistor Underwriter’s Laboratory Universal Serial Bus Comfort Panels INOX, ITC INOX Compact Operating Instructions, 09/2017, A5E33472156-AI...

Table of Contents