The following figure shows the PSU.
Figure 13. 2200 W PSU
Dual PSUs provide redundant power for the system. If one PSU fails, the other keeps the system running
while you replace the faulty module. The PSUs are hot-swappable. Replacement of a PSU can be
performed while the enclosure is running, but the procedure must be completed within 2 minutes of the
removal of the defective PSU. Ensure that you have a replacement PSU before you remove the defective
PSU.
The enclosure chassis is keyed to prevent PSUs from being inserted upside down.
The back of the PSU has a power switch, three status LEDs, and a socket for the power cord, as shown in
the following figure.
Figure 14. PSU LEDs
Power supply unit (2800 kW PSU)
Power is provided by two 2800 W PSUs. These units require an input of 200 to 240 VAC at 50 to 60 Hz.
15
Chapter 2. System overview