Page 9
DANGER: Electrical current from power, telephone, and communication cables is hazardous. To avoid shock hazard, connect and disconnect cables as shown below when installing, moving or opening the covers of this product or attached devices. The power cord must be used with a properly grounded outlet. To Disconnect To Connect Turn everything OFF.
Page 10
DANGER: Le courant électrique provenant des câbles d’alimentation, télephoniques et de transmission peut présenter un danger. Pour éviter tout risque de choc électrique, connectez et déconnectez ces câbles comme indiqué ci- dessous lorsque vous installez ou déplacez ce matériel ou les unités connectées, ou que vous soulevez un carter.* Pour connecter Pour deconnecter...
Page 21
Power OK Indicator Hard Disk Drive Activity Indicator Power On/Off Switch...
Page 22
Open Bays CD-ROM Drive Diskette Drive Hard Disk Drives Open Bays...
Page 94
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Enter Size Array Array Array Create/Delete Array of Logical Drive,(MB) 1. Help 2. Delete Disk Array 3840 3. Create Disk Array 4.
Page 97
Select Adapter 1. Help 2. ServeRAID Adapter 1 3. ServeRAID Adapter 2 4. Exit Multiple IBM ServeRAID Adapter found in the system. Select a choice using the Up Arrow ( ) and Down Arrow ( ) keys and press Enter.
Page 98
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Main Menu 1. Help 2. View Configuration 3. Create/Delete Array/Log Drive 4. Initialize/Synchronize Log Drive 5. Rebuild Device Management 6. Advanced Functions 7.
Page 100
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config View Configuration Array Array Array Array Size RAID Date Status ID Size (MB) Level Created 4300 RAID-0 12/12/95 4300 RAID-0...
Page 102
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Create/Delete Array Array Array Array 1. Help 2. Delete Disk Array 3. Create Disk Array 4. Define Logical Drive 5. Define/Undefine Hot-spare Drive 6.
Page 104
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Enter Size Array Array Array Create/Delete Array of Logical Drive,(MB) 1. Help 2. Delete Disk Array 3840 3. Create Disk Array 4.
Page 108
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Create/Delete Array Array Array Array 1. Help 2. Delete Disk Array 3. Create Disk Array 4. Define Logical Drive 5. Define/Undefine Hot-spare Drive 6.
Page 110
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Create/Delete Array Array Array Array 1. Help 2. Delete Disk Array 3. Create Disk Array 4. Define Logical Drive 5. Define/Undefine Hot-spare Drive 6.
Page 111
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Create/Delete Array Array Array Array 1. Help 2. Delete Disk Array 3. Create Disk Array 4. Define Logical Drive 5. Define/Undefine Hot-spare Drive 6.
Page 115
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Drive Information Array Array Array Vendor ID : IBM Model : 0664N1H 5 500003 Version : 3404 Capacity : 1920 MB...
Page 119
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Rebuild/Device Management Array Array Array 1. Help 2. Set Device State 3. Rebuild Logical Drive 4. Display Drive Information 5. Erase Device Error Table 6.
Page 122
Amber Light Green Light Power-Off Switch Locked Position...
Page 129
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Init/View/Synchronize Config 1. Help 2. Initialize Configuration 3. View NVRAM Configuration 4. View EEPROM Configuration 5. View Hard Drive Configuration 6.
Page 130
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Select Configuration Source Array Array Array 1. EEPROM as Source 2. NVRAM as Source 3. NVRAM+POCL as Source 4. Hard Disk Drive as Source 5.
Page 134
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Advanced Functions Array Array Array 1. Help 2. Backup config. to Diskette 3. Restore config. from Diskette 4. Change Write Policy 5.
Page 137
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Advanced Functions Array Array Array 1. Help 2. Backup config. to Diskette 3. Restore config. from Diskette 4. Change Write Policy 5.
Page 141
IBM PC ServeRAID Adapter Disk Array Configuration Ver. 1.XX Adapter Number: 1 Bus Number: 0 Host ID = Null Config Display/Change Adapter Parameter Array Array Array 1. Help 2. Display Adapter Status 3. Change Adapter Host/SCSI ID 4. Set BIOS Compatability Mapping 5.
Page 145
IBM PC ServeRAID Adapter Disk Array Mini-Configuration Ver. 1.XX View Adapter Configuration Information No: 1 Bus: 0 Slot: 14 Size RAID Current Stripe Read Date Created Logical Logical (MB) Level State Size Ahead mm/dd/xx Drive Drive 01/18/96 01/18/96 01/18/96 01/18/96...
Page 151
10BaseT 10BaseT Net 1 Net 5 10BaseT 10BaseT Net 6 Net 2 Router Protocol LAN Driver LAN Driver Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 4 Port 3 Adapter 1 Adapter 2 System Bus Net 7 Net 3 10BaseT...
Page 153
10BaseT 10BaseT Net 1 Net 1 HUB 1 HUB 5 10BaseT 10BaseT HUB 6 HUB 2 Protocol Net 1 Net 1 Virtual Network Layer LAN Driver LAN Driver Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Adapter 1 Adapter 2 Port 1...
Page 155
10BaseT 10BaseT Net 2 Net 1 HUB 5 HUB 1 10BaseT 10BaseT Router HUB 2 HUB 6 Net 1 Protocol Net 2 Virtual Network Layer LAN Driver LAN Driver Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4 Adapter 2 Adapter 1 Port 1...
Page 156
10BaseT 10BaseT Net 2 Net 1 HUB 1 HUB 5 Router 10BaseT 10BaseT HUB 2 HUB 6 Protocol Protocol Net 3 Net 1 Virtual Network Layer LAN Driver LAN Driver Port 4 Port 3 Port 2 Port 1 Port 1 Port 2 Port 3 Port 4 Adapter 1 Adapter 2 Port 1...
Page 161
Diagnostic Error LED DRAM SIMM Socket Port 1 Port 2 Port 3 Port 4 Straight-through Crossover...
Page 169
Main Menu Select one: 1. Start operating system 2. Backup of system diskettes 3. Set/View MicroChannel configuration 4. Copy an option diskette 5. Test the computer Enter F1=Help F3=Exit...
Page 180
Main Menu Select one: 1. Start operating system 2. Backup of system diskettes 3. Set/View MicroChannel configuration 4. Copy an option diskette 5. Test the computer Enter F1=Help F3=Exit...
Page 182
Change Configuration Slot 1 - IBM Ethernet Adapter/A Adapter Media Type Selection ........
Page 317
Main Menu Select one: 1. Start operating system 2. Backup of system diskettes 3. Set/View MicroChannel configuration 4. Copy an option diskette 5. Test the computer Enter F1=Help F3=Exit...
Page 319
Main Menu Select one: 1. Start operating system 2. Backup of system diskettes 3. Set/View MicroChannel configuration 4. Copy an option diskette 5. Test the computer Enter F1=Help F3=Exit...
Page 336
\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\/\\/\/\/\/\/\/\/\/\ QAPlus/PRO for PC Server v 5.20 System Board Test Group Main Menu : PENTIUM IBM PC Server (MC) Diagnostics Menu : INTERNAL BIOS : IBM Bus Type: MC Module Tests Menu CMOS Clock/Calendar Present Ref Int 30 ( ) System Board...
Page 390
Change Configuration Slot 1 - IBM Ethernet Adapter/A Adapter Media Type Selection ........
Page 404
Memory Riser Slot L2 Cache Slot Battery Voltage Video Regulator Primary Pentium Optional Secondary Pentium PCI Slots Micro Channel Slots SCSI Narrow SCSI Internal Fast and Wide SCSI External Fast and Wide Mouse Diskette Drive Connector Keyboard Parallel Port Serial Ports Power Connectors...
Page 405
Open Bays CD-ROM Drive (Bay A1) Diskette Drive (Bay A2) B1 B2 Bank C Bays 1 - 6 Bank D Open Bays Bays 1 - 6 Bank E Bays 1 - 6...