. Linearity Adjustment (2)
Note 1)Connect the monoscope signal or the cross-hatch
signal having the following signal formats as
shown in the table below, to the ANALOG Y/G
input connector. Perform the linearity adjustment
(2) in the respective screen modes using the
respective signal formats.
60 Hz system
MODE
Signal format
MODE1
1080/60i
MODE2
(1125)
MODE3
1035/60i
MODE4
(1125)
MODE5
720/60p
MODE6
MODE7
480/60p
MODE8
(525)
MODE9
MODE10
MODE11
480/60i
MODE12
(525)
MODE13
MODE14
50 Hz system
MODE
Signal format
MODE15
1080/48i
MODE16
(1125)
MODE17
1080/50i
MODE18
(1125)
MODE19
720/50p
MODE20
MODE21
575/50P
MODE22
(625)
MODE23
MODE24
MODE25
575/50i
MODE26
(625)
MODE27
MODE28
BVM-D9H1U/D9H5U/D9H1E/D9H5E/D9H1A/D9H5A
Screen mode
16 : 9
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
4 : 3
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
4 : 3
NORMAL
UNDER SCAN
Screen mode
16 : 9
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
4 : 3
NORMAL
UNDER SCAN
16 : 9
NORMAL
UNDER SCAN
4 : 3
NORMAL
UNDER SCAN
Note 2)The following adjustment menus are located in the
directory under the DEFLECTION menu of the
MAINTENANCE menu.
H SIZE
H CENTER
H KEY BAL
H KEY
H PIN BAL
H PIN
H COR S
H COR PIN
H PIN
V SIZE
V CENTER
V LIN AMP
V LIN BAL
1. Connect the monoscope signal to the ANALOG Y/G
input connector.
2. Press the SHIFT button to ON. [The LED (orange) on
top of the button turns on.]
3. To adjust the 4:3 mode of adjustment, press the 16:9
OFF button [to turn off the LED (orange)] to select the
4:3 mode.
4. Press the SHIFT button to OFF. [The LED (orange)
on top of the button turns off.]
5. To select the NORMAL mode of adjustment, press the
UNDER SCAN button (
select the normal mode. [The green LED turns off.]
To select the UNDER SCAN mode of adjustment,
press the UNDER SCAN button (
position to select the under scan mode. [The green
LED turns on.]
6. Adjust the H CENTER data so that the horizontal
center of the picture comes to the horizontal center of
the screen.
7. Adjust the V CENTER data so that the vertical center of the
picture comes to the vertical center of the screen.
8. Connect the cross-hatch signal to the ANALOG Y/G
input connector.
9. Adjust the respective V SIZE, V LIN BAL, V LIN
AMP and H SIZE data so that the optimum picture is
obtained as shown in Fig. 1-8.
Note: Do not adjust the V SIZE data when adjusting the
MODEs 9, 13, 23 and 27.
10. Adjust the trapezoidal distortion and PIN distortion on
both sides of picture using the H KEY BAL, H KEY,
H PIN BAL and H PIN data respectively as shown in
Fig. 1-9.
11. Adjust the corner "S" distortion and the corner PIN
distortion on both sides of picture using the H CORS and
H COR PIN data respectively as shown in Fig. 1-10.
12. Repeat the above-described steps of the linearity
adjustment(2) until the optimum horizontal linearity