4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition
CA210 : CH 9, Test signal : Inner pattern (85IRE)
· Above 5 minutes H/run in the inner pattern. ("power on" key
of adjust remote control)
Cool
11,000k
ºK
X=0.276(±0.002)
Y=0.283(±0.002)
Medium 9,300k
ºK
X=0.285(±0.002)
Y=0.293(±0.002)
Warm
6,500k
ºK
X=0.313(±0.002)
Y=0.329(±0.002)
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON ->
Enter the mode of White-Balance, the pattern will come out
Full White Pattern
RS-232C Communication
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer's Prove vertically.(80~100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 15minutes.
- Using 'no signal' or 'full white pattern' or the others,
check the back light on.
• Auto adjustment Map(RS-232C)
RS-232C COMMAND MIN
[CMD ID DATA]
Cool
Mid
Warm
R Gain
jg
Ja
jd
G Gain
jh
Jb
je
B Gain
ji
Jc
jf
R Cut
G Cut
B Cut
** Caution **
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
<Test Signal>
Inner pattern
(216gray,85IRE)
CA-210
COLOR
ANALYZER
TYPE: CA-210
CENTER
MAX
(DEFAULT)
Cool
Mid
Warm
00
172
192
192
255
00
172
192
192
255
00
192
192
172
255
64
64
64
128
64
64
64
128
64
64
64
128
* Manual W/B process using adjusts Remote control.
• After enter Service Mode by pushing "ADJ" key,
• Enter White Balance by pushing "
Balance".
* After done all adjustments, Press "In-start" button and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory JIG model.
* Push The "IN STOP KEY" after completing the function
inspection.
4.2. DDC EDID Write (RGB 128Byte )
• Connect D-sub Signal Cable to D-sub Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Ass'y, EDID have to be downloaded to Insert
Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
• Connect HDMI Signal Cable to HDMI Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Ass'y, EDID have to be downloaded to Insert
Process in advance.

4.4. EDID DATA

1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum