Event Code: 582
Message:
Bit-error threshold exceeded
Severity:
Major
Explanation:
The number of code violation errors recognized by the incident node has exceeded a threshold (see FC-PH
clause 5.1).
Action:
A Link-incident Record (LIR) is generated and sent to the host using the Link-Incident reporting procedure
defined in the T11/99-017v0 document. If, after fault isolation is performed by the host, it is determined that the
incident is because of a port failure, perform a data collection procedure for this switch using the EFC manager,
and return the CD to IBM for analysis.
Event Data:
Byte 0 = Port number (00-8F)
Bytes 4-7 = Elapsed millisecond tick count.
Distribution:
Switch
Nonvolatile
System
Event Log
484
SAN32M1 Fabric Switch Installation and Service Manual
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
Host
Sense Info
Link Incident