282
SAN32M1 Fabric Switch Installation and Service Manual
Event
Explanation
Code
070
E_Port is segmented.
071
Switch is isolated.
072
E_Port connected to an unsupported switch.
140
Congestion detected on an ISL.
142
Low BB_Credit detected on an ISL.
150
Zone merge failure.
3
Is fault isolation being performed at the EFC Server?
YES
NO
↓
Fault isolation is being performed through the SANpilot
interface. Go to
4
Does a yellow triangle (attention indicator) appear to overlay the port
graphic at the Hardware View?
YES
NO
↓
The problem is transient and the switch-to-fabric device
connection appears operational.
5
Inspect the port state and LED status for the port.
a. At the Hardware View, click the port graphic. The Port Properties
dialog box displays.
step
18.
Action
Go to
step
10.
Go to
step
10.
Go to
step
11.