A fan failure is indicated. Continue to the next step to obtain event
codes. If no event codes are found, go to
card failure analysis
on page 256.
52
Obtain event codes from the SANpilot event log.
If multiple event codes are found, note all codes and associated severity
levels. Record the date, time, and listed sequence, and determine if the
codes are related to the reported problem. Begin fault isolation with the
most recent event code with the highest severity level. Other codes may
accompany this event code, or may indicate a normal indication after a
problem is recovered.
a. At the View panel, select Monitor at the left side of the panel. The
Monitor panel opens with the Port List page displayed.
b. At the Monitor panel, click the Log tab. The Monitor panel (Log
tab) displays.
c. Record the event code, date, time, and severity (Informational,
Minor, Major, or Severe).
d. Record all event codes that may relate to the reported problem.
Were one or more event codes found?*
YES
NO
↓
Return to the MAP step that sent you here.
Go to
Table 10
on page 192.
MAP 0500: fan and CTP
Chapter 3: Diagnostics
217