hit counter script
Honeywell SLN 700 User Manual
Honeywell SLN 700 User Manual

Honeywell SLN 700 User Manual

Smartline level transmitter non-contact radar
Hide thumbs Also See for SLN 700:
Table of Contents

Advertisement

Quick Links

SLN 700
SmartLine Level Transmitter
Non-Contact Radar
User's Manual
34-SL-25-13
Revision 2
March 2023
Honeywell Process Solutions

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell SLN 700

  • Page 1 SLN 700 SmartLine Level Transmitter Non-Contact Radar User’s Manual 34-SL-25-13 Revision 2 March 2023 Honeywell Process Solutions...
  • Page 2 In no event is Honeywell liable to anyone for any indirect, special, or consequential damages. The information and specifications in this document are subject to change without notice.
  • Page 3 Honeywell’s family of SLN 700 SmartLine Non-Contact Radar Level Transmitters. For details on the HART protocol, refer to the SLN 700 Series HART Option User’s Manual, Document #34-SL-25-16. The configuration of your Transmitter depends on the mode of operation and the options selected for it with respect to operating controls and mechanical installation.
  • Page 4 #34-SL-25-16 • SLN 700 SmartLine NCR Level Transmitter Specification, #34-SL-03-06 SLN 700 SmartLine NCR Quick Start Guide (in the box), #34-SL-25-14 Support and Contact Information For Europe, Asia Pacific, North and South America contact details, refer to the back page...
  • Page 5 Chassis Ground: Identifies a connection to the chassis or frame of the equipment shall be bonded to Protective Earth at the source of supply in accordance with national and local electrical code requirements. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page v...
  • Page 6 The Ex mark means the equipment complies with the requirements of the European standards that are harmonized with the 2014/68/EU Directive (ATEX Directive, named after the French "ATmosphere EXplosible"). SLN 700 SmartLine NCR Level Transmitter User’s Manual Page vi Revision 2...
  • Page 7: Table Of Contents

    Recycling and disposal of product ..................15 Operating the Transmitter .................. 16 Functions of keys ........................16 Programming menu description .................... 18 Maintenance ...................... 40 Configuration method ......................40 Configuration with Display ....................40 SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page vii...
  • Page 8 Glossary ........................43 List of Figures Figure 1-1 Components of the Level transmitter ..............1 Figure 1-2: SLN 700 Transmitter label example ..............3 Figure 1-3: Standard SLN 700 Model Number ..............4 Figure 3-1: Graphical illustration ................... 6 Figure 3-2: Moisture-proof diagram ..................7 Figure 3-3: Installation position, >200 mm ................
  • Page 9: Introduction

    Guided Wave Radar (GWR) are not suitable. 1.2 Transmitter Models The SLN 700 SmartLine 80 GHz NCR transmitter is available as a part of the family of SLN700L models for liquid and SLN700S for solid applications. The pressure and temperature range is -40 to 200°C/-1 to 40 bar for both, and each model is...
  • Page 10: Electronics

    87 Series Solid Storage vessel/process Flange options vessel or high dust applications For list of all options and accessories refer to the product specifications available at www.process.honeywell.com/level-transmitters. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 2 Revision 2...
  • Page 11: Communicating With The Transmitter

    Model number • Physical configuration • Power supply voltage • Maximum working pressure rating • Certification, if ordered (IECEx and CSA) Figure 1-2: SLN 700 Transmitter label example SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 3...
  • Page 12: Transmitter Model Number Description

    SLN transmitter models are available for use in Intrinsic Safe locations, including IECEx, ATEX, INMETRO, and NEPSI approvals. See SLN700 Product Specification (34-SL-03-06) or SLN700 Quick Start Guide (34-SL-25-14) for details and other approvals. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 4 Revision 2...
  • Page 13: Radar Level Measurement

    Fourier Transform technique to calculate the difference between the frequency of the generated and reflected signal. This difference is proportional to the distance of reflection. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 5...
  • Page 14: Mounting

    Figure 3-1: Graphical illustration 1. Near distance 2. Far distance 3. Distance at which sensor reads 100% level (or current) 4. Distance at which sensor reads 0 % level (or current) SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 6 Revision 2...
  • Page 15: Moisture-Proof

    200mm to the vessel wall or values calculated from Table 3-1. Figure 3-3: Installation position, >200 mm 1. Reference plane 2. Center of the vessel or symmetry axis. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 7...
  • Page 16: Nozzle Installations

    The background subtraction ("virtual echo learning") feature can further reduce false echoes from nozzle openings. Table 3-2 shows detail of the size limitations of the nozzle. Figure 3-5: nozzle specifications diagram SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 8 Revision 2...
  • Page 17: Correct And Incorrect Installation Position

    2. Correct. Note: Sun-shading and rain proof measures must be adopted for the outdoor installation. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 9...
  • Page 18: Installation Of Reflecting Plate

    It will eliminate the influence of false echo generated by mixing blades. If foam or wave is generated due to agitation, then the customer should consider a guided wave radar sensor such as the Honeywell SLG-700 series.
  • Page 19: Transmitter Installation

    Maximum Loop Resistance (Ω) Maximum Loop Resistance (Ω) Figure 4-1 Table 4-1: Maximum Loop Resistance (Ω) Supply Max. Loop Resistance (Ω) Voltage (VDC) 17.5 SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 11...
  • Page 20: Installation Of Connecting Cables

    2-Wire 2-wire wiring used for HART (electronic unit B) Figure 4-2: 2-wire wiring for HART Note: For intrinsic safety installations, shield is normally terminated at one end only. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 12 Revision 2...
  • Page 21: Hazardous Location - Intrinsic Safety

    Intrinsically Safe: Ex ia IIC T6…T2 Ga (Brazil) Ex ia IIIC T85°C …T300°C Da Intrinsically Safe: CCoE Ex ia IIC T6…T2 Ga (India) Ex ia IIIC T85°C …T300°C Da SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 13...
  • Page 22: Figure 4-3: Intrinsically Safe Wiring

    T6/85℃ -40 to +60 -40 to +95 T5/100℃ -40 to +130 T4/135℃ -40 to +195 -40 to +70 T3/200℃ -40 to +200 T2/300℃ Figure 4-3: Intrinsically Safe Wiring SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 14 Revision 2...
  • Page 23: Recycling And Disposal Of Product

    4.5 Recycling and disposal of product Consider recycling the product and packaging materials. The product should be disposed of in accordance with local and national regulations. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 15...
  • Page 24: Operating The Transmitter

    • Select to edit the parameter. digit. • Parameter item content display. • Enter the programming state. • Enter Verify the programming item. • Confirm the parameter modification. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 16 Revision 2...
  • Page 25 When the menu switches to changing a numeric or character number value, the first of those digits highlighted. At this point, you can parameter press key to change the character/number until the programming desired character/number appears. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 17...
  • Page 26: Programming Menu Description

    Liquid level Medium Liquid Solid 1.2 Length The length unit provides the user with the choice of measuring Unit in metric or imperial system. When displaying the medium SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 18 Revision 2...
  • Page 27 Display in LCD is as follows. Near blanking Press to enter the status of parameter editing. After editing, press to confirm. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 19...
  • Page 28 Display in LCD is as follows. When the menu number is 1.7, press key to enter the Max Product Level. Display in LCD is as follows. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 20 Revision 2...
  • Page 29 1.9 Hart Config This setting is used to set all the parameters about the HART protocol and output.the current output mode. Press enter the HART Config menu for detail settings. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 21...
  • Page 30 This setting is used to set parameters for Volume calculation. Press to enter the Volume configuration menu for detail settings and Display in LCD is as follows Current Output 1.10 Volume Config SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 22 Revision 2...
  • Page 31 Menu 1.10.2. The Display in LCD is as follows. Press to enter the tank type selection. There are 7 types for selection. The Display in LCD is as follows SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 23...
  • Page 32 1.10.4 for tank length input. The Display in LCD is as follows. Press to set the length and press to confirm the setting. 1.10.4 Tank Length SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 24 Revision 2...
  • Page 33 Volume Offset = Actual product Volume - calculated product Volume 1.11 Sensor When the menu number is 1.10, press key to move the menu to the sensor tag display item. Display in LCD is as follows. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 25...
  • Page 34 Percent key to move the arrow to the wanted parameter and press to confirm. After editing, press to exit the display programming and return to the upper menu. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 26 Revision 2...
  • Page 35 Language options are current Chinese and English only. When LCD displays unit of Volume (menu number 2.3), press key to enter the language setting function. Display in LCD is as follows. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 27...
  • Page 36 The EFF curve show the final analyzed echo curve in logarithm units Threshold setting is used to set the threshold size of the effective echo. The larger the threshold setting is, the stronger the SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 28 Revision 2...
  • Page 37 Enter the corresponding setting menu, and press to confirm after completing the value setting. From them on, the sensor current value is set to the corresponding value. There are presently two options: SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 29...
  • Page 38 3.6 Calibration Date The default value is calibration date from factory. User can enter the new date after they performed a calibration. That is the end of Diagnostics menu settings. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 30 Revision 2...
  • Page 39 Display in LCD is as follows. Output Mode No change 21.5 mA 3.6 mA Press the key and choose the desired setting and press to confirm your selection. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 31...
  • Page 40 Device will only read signal strength above Envelop level. Default envelop level DB value is 5. User can set different value by referring to EFF curve based on site situation. See Figure 5-2 for the definition of this parameter. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 32 Revision 2...
  • Page 41 This option multiplies the amplitude of the first wave by a factor. Big :amplitude of the first wave*1.2 Small :amplitude of the first wave*0.7 Normal: amplitude*1.0 SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 33...
  • Page 42 SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 34 Revision 2...
  • Page 43 When the LCD displays 4.11, press to enter the Multi Wave setting menu. Display in LCD is as follows. The default setting is Yes. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 35...
  • Page 44 Amplitude; the ending point distance/the ending point Amplitude. According to the input value, the system adds a straight line connecting two points to the existing false echo. Example: SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 36 Revision 2...
  • Page 45 Advanced Settings System Press to enter the information display function. Display in LCD is as follows. 5.1 Info Information SLN700 Product Type Product Serial Number (ID) Production date (PD) SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 37...
  • Page 46: Figure 5-2: Representation Of An Echo Curve Defining The Echo Threshold And The Envelope Offset Quantities

    If switching No to Yes, go to set lock Password Input Menu. Figure 5-2: Representation of an echo curve defining the Echo Threshold and the Envelope Offset quantities. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 38 Revision 2...
  • Page 47 SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 39...
  • Page 48: Maintenance

    Maintenance 6.1 Configuration method There are three debugging methods for SLN 700 1. Display/configuration module 2. Host PC 3. HART hand-held programmer Configuration with Display Display modular is a pluggable display/configuration tool. The configuration can be done through operating with 4 buttons on Display. The language for the configuration menu is optional.
  • Page 49: Configuration

    Transmitter and the PC Host/Handheld Configurator 2. On the Host visit Services Tab under Advanced Configuration menu. 3. Select the Loop Test button; the LOOP TEST box will be displayed. SLN 700 SmartLine Non-Contact Radar User’s Manual Revision 2...
  • Page 50: Error Codes

    Return to Factory No Signal Error No signal back, will see no reflective echo on echo curve Check antenna aiming Check if the application is having excessive vapor/steam SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 42 Revision 2...
  • Page 51: Glossary

    Digital to Analog Convertor (DAC): A function that converts digital data (usually binary) into an analog signal (current, voltage). Device Description (DD): Files describing the configuration of a transmitter for use by handheld or PC applications. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 43...
  • Page 52 Communications Protocol: Highway Addressable Remote Transducer (HART) is a digital industrial automation protocol that is modulated over legacy 4-20 mA analog instrumentation wiring Honeywell Experion: An advanced distributed control system (DCS) and innovative software applications to improve users' business performance and ensures reliable performance.
  • Page 53 Low frequency microwave pulses are guided by a metal probe and reflected off a surface to determine levels in tanks. Operating Range: The range of conditions in which the transmitter is designed to operate. SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 45...
  • Page 54 Secondary Variable (SV): A secondary dynamic feature of the process which may change rapidly and is measured. (HART only) Stillwell / Stilling well: A chamber that enables level measurement in turbulent conditions. SLN 700 SmartLine NCR Level Transmitter User’s Manual Page 46 Revision 2...
  • Page 55 Upper Range Value (URV): A Basic configuration parameter which allows users to enter the measuring value for which the analog output will be scaled to 20 mA (HART only). SLN 700 SmartLine NCR Level Transmitter User’s Manual Revision 2 Page 47...
  • Page 56 Procedures ............38 Moisture-proof ............7 Operating the Transmitter ........17 Functions of keys .......... 17 Programming instruction ........18 Programming menu structure ......18 Operation ............... 5 Overview ..............1 SLN 700 SmartLine Non-Contact Radar User’s Manual Revision 2...
  • Page 57 Phone: +(822) 799 6114 Fax: +(822) 792 9015 For more information To learn more about SmartLine Transmitters, visit www.process.honeywell.com Or contact your Honeywell Account Manager Process Solutions Honeywell 1250 W Sam Houston Pkwy S Houston, USA, TX 77042 Honeywell Control Systems Ltd...

Table of Contents