Chapter 4
Technical Specifications
Section 4.2
Power Consumption
Typical Power Consumption
Section 4.3
Radio and Modem Specifications
Operating Frequency
Wireless Communication
Standard
Operating Mode
Channel Bandwidths
Frequency Resolution
Transmission Mode for MIMO
Antenna Type
Number of Ports for External
Antenna(s)
Type of Ports for External
Antenna(s)
Output Power (Average)
Size of Fast Fourier Transform
(FFT) Channels
Type of Modulation
Dynamic Range (Receiver)
Dynamic Range (Transmitter)
Section 4.4
Operating Environment
The RUGGEDCOM WIN5118 is rated to operate under the following environmental conditions.
Ambient Operating
a
Temperature
Ambient Storage Temperature
Ambient Relative Humidity
30
12 W
1785 to 1805 MHz
IEEE 802.16e-2009
Time-Division Duplexing (TDD)
3.5 MHz
5 MHz
7 MHz
10 MHz
250 kHz
MRC/STC (downlink)
External RF
2
N-Connect female
27 dbm
1024/512FFT
QPSK, 16-QAM, 64-QAM
-20 to 100 dBm
-20 to 27 dBm
-40 to 75 °C (-40 to 167 °F)
-40 to 75 °C (-40 to 167 °F)
b
5% to 95%