If following the steps in Table 16 on page 65 did not correct the problem, continue
with the steps shown in "RSA card connection failure".
RSA card connection failure:
1. Verify node has power using rpower query command.
2. If network connection LED is on for the RSA card at the Ethernet switch, go to
Node connection or command failure: If the RSA card connection is working, but
the node connection or commands issued to the node fail:
v Connect to the RSA card and verify node list.
v Verify cabling.
v Go to "Node checks" on page 63 and perform node checks.
66
Installation and Service
Table 16. Troubleshooting the service processor network (continued)
1. The rpower —a query command does
not return with the status of all nodes
2. Cannot see all the nodes when managing
remote ASMs.
3. Cannot connect to individual RSA cards
using browser.
a. If node has power, ping the RSA card using the HWControlPoint field in
lsnode output.
1) If ping succeeds, reset adapter. If adapter connection continues to fail
after it has been reset contact IBM support.
2) If ping fails, check network connection.
b. If node does not have power, check power connections.
"Resetting RSA cards" on page 72 and reset the RSA adapter.
1. Check the physical connections on the
RS485 network and check for errors..
2. From the Management Node use the
web browser and try to link up with
the failing node through the failing
node's RSA card.
3. Check that the RSA network is properly
terminated. When more than one node
is connected, terminators should be
plugged into the empty port on the
dongle and in the second RS485 port of
the last node in the chain.
4. Swap the internodal Cat 5 cable on the
unresponsive node with a known good
cable. Also, replace the dongle if a
problem is suspected.
5. Swap the KVM/RS485 cable (on the
x335 only) with a known good cable.
Also, replace the dongle if a problem is
suspected.
6. Verify the RSA configurations/IP
settings with support.
7. Verify the 10/100 ethernet link from the
RSA card to the Cisco 3550 or 400x
switch.
8. Flash the ASM to the latest firmware
level.
9. Flash the RSA to the latest firmware
level.
10. Check RSA configurations using the
firmware update diskette.