MicroHarmony Cell Sizes 40 - 260A Manual

9.4 General Information

10000424.
1
Bus Inductance
Power Plug maximum current
Power Plug useful life
1 Measured at nominal dc bus voltage, rated output current. Includes capacitor self inductance, bus inductance, and
IGBT module inductance.
19001467: Version 1.0
040
070
100
229nH
91nH
73nH
300Arms at 55 °C plug ambient, 25CFM
Mechanical life test at 250 insertions/extractions with no significant change in
resistance
s
Application Notes
140
10000494.200
63nH
126nH
10000494.260
127nH
9
9-5